Gastec GV110-S-TR

Gastec GV110-S-TR Gas SampBrugermanual til pumpe med slagtæller

Model: GV110-S-TR

1. Introduktion

This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of the Gastec GV110-S-TR Gas Sampling Pump with Stroke Counter. This device is designed for accurate measurement of gas and vapor concentrations using Gastec Detector Tubes.

The Gastec Detector Tube and Pump System is engineered for ease of use while maintaining high safety standards. Please read this manual thoroughly before operating the pump.

2. Sikkerhedsoplysninger

Always adhere to local safety regulations and guidelines when using the Gastec Gas Sampling Pump. Failure to follow safety instructions may result in inaccurate readings, personal injury, or damage to the equipment.

3. Produktet er slutview og komponenter

The Gastec GV110-S-TR Gas Sampling Pump is a robust, hand-operated device designed for precise air sampling. Key components include:

Gastec GV110-S-TR Gas Sampling Pump with Stroke Counter

Figure 1: Gastec GV110-S-TR Gas Sampling Pump. The image shows the black pump body with the GASTEC logo, a clear section revealing the stroke counter (numbered 1-6), a thermal ring displaying temperatures (32-104°F), a tip breaker on the left, and a flow finish indicator on the right.

Hvad er inkluderet:

4. Opsætning

Before initial use, ensure all components are present and undamaged. Familiarize yourself with the pump's parts as described in Section 3.

  1. Inspicer pumpen: Check the pump body for any visible damage. Ensure the piston moves smoothly.
  2. Tjek tilbehør: Verify that the carrying case and spare parts kit are complete.
  3. Prepare Detector Tube: Select the appropriate Gastec Detector Tube for the gas or vapor to be measured. Carefully break both ends of the detector tube using the integrated tip breaker on the pump.
  4. Insert Detector Tube: Insert the detector tube into the rubber inlet of the pump with the arrow on the tube pointing towards the pump. Ensure a snug fit to prevent air leakage.

5. Betjeningsvejledning

Follow these steps for accurate gas sampling:

  1. Prepare for Sampling: With the detector tube inserted, position the pump in the area where the gas concentration needs to be measured.
  2. Perform a Full Stroke: Pull the pump handle out completely until it locks into place. This constitutes one full stroke. The stroke counter will advance by one.
  3. Observe Flow Finish Indicator: Wait for the flow finish indicator to appear. This confirms that the required volume of air has been drawn through the detector tube. The indicator is typically a red dot or line that appears when the flow is complete.
  4. Repeat Strokes (if necessary): If the specific detector tube requires multiple strokes, push the handle back in and repeat steps 2 and 3 for the specified number of strokes. The stroke counter will keep track.
  5. Read the Detector Tube: After completing the required strokes, remove the detector tube and read the concentration directly from the scale on the tube, following the tube's specific instructions. Note the ambient temperature from the thermal ring for any necessary corrections.
  6. Dispose of Tube: Properly dispose of used detector tubes according to local regulations.

Note: Always refer to the specific instructions provided with each Gastec Detector Tube for accurate sampling times and number of strokes.

6. Vedligeholdelse

Regular maintenance ensures the longevity and accuracy of your Gastec Gas Sampling Pumpe.

7. Fejlfinding

This section addresses common issues you might encounter with your Gastec Gas Sampling Pumpe.

ProblemMulig årsagLøsning
Pump handle does not pull out smoothly.Lack of lubrication on the piston.Apply lubricant from the spare parts kit to the piston shaft.
Flow finish indicator does not appear.Leaky connection with detector tube or damaged rubber inlet.Ensure detector tube is inserted correctly and snugly. Replace rubber inlet if damaged.
Upræcise aflæsninger.Incorrect number of strokes, expired detector tube, or improper tube insertion.Verify the number of strokes required for the specific tube. Check tube expiration date. Re-insert tube correctly.

If the problem persists, contact Gastec customer support or an authorized service center.

8. Specifikationer

FeatureDetalje
ModelnummerGV110-S-TR
MærkeGastec
Varens vægt3 pund
FunktionerIntegrated Stroke Counter, Thermal Ring, Tip Breaker, Flow Finish Indicator
KompatibilitetGastec Detector Tubes

9. Garanti og support

The Gastec Gas Sampling Pump with Stroke Counter includes a lifetime warranty, as stated in the product description. For warranty claims, technical support, or service inquiries, please contact Gastec customer service or your authorized distributor.

Refer to the official Gastec webwebstedet eller de kontaktoplysninger, der fulgte med dit køb, for at få de mest opdaterede supportoplysninger.

Relaterede dokumenter - GV110-S-TR

Preview Gastec nr. 146 isopropylacetatdetektorrør, instruktioner og specifikationer
Detaljerede instruktioner, specifikationer og sikkerhedsoplysninger for Gastec nr. 146 isopropylacetatdetektorrør, herunder måleprocedurer, interferenser og korrektionsfaktorer for gasdetektion.
Preview Gastec Gas Sampling Pump GV-100S and GV-110S Instruction Manual
Comprehensive instruction manual for Gastec Gas Sampling Pumps GV-100S and GV-110S, covering safe usage, operation, maintenance, and troubleshooting for accurate gas detection.
Preview GASTEC Fluorchlorcarboner Pyro Tube nr. 51: Instruktioner og specifikationer
Detaljerede instruktioner, specifikationer og sikkerhedsretningslinjer for brug af GASTEC fluorchlorcarbonpyrorør nr. 51 med Gastec Gas SampLingpumper og Pyrotec-pyrolysatorer til detektering af fluorchlorcarboner.
Preview Gastec 30m forlængerslange nr. 351A-30: Brugsanvisning og brugervejledning
Detaljeret brugsanvisning til Gastec 30m forlængerslange (nr. 351A-30), der dækker sikker betjening, specifikationer, måleprocedurer og sampVarmetid/korrektionsfaktorer for gasdetektion.
Preview Gastec 126L klorbenzen-detektorrør: Instruktioner og specifikationer
Omfattende instruktioner og specifikationer for Gastec 126L klorbenzen-detektorrøret, med detaljerede oplysninger om sikker betjening, måleprocedurer, temperatur-/fugtigheds-/trykkorrektioner og interferensinformation.
Preview Gastec nr. 15L salpetersyredetektorrør, instruktioner og specifikationer
Detaljerede instruktioner, specifikationer og anvendelsesvejledning til Gastec nr. 15L salpetersyredetektorrør, inklusive måleprocedurer, korrektioner og sikkerhedsoplysninger.