Indledning
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of your American Lighting LED Complete 2 Under Cabinet Fixture. This 120-Volt dimmable warm white LED fixture is designed for efficient and uniform lighting in various indoor applications.

Image: The American Lighting LED Complete 2 Under Cabinet Fixture, a white, rectangular LED light bar with a switch on the front, designed for under-cabinet installation.
Vigtige sikkerhedsoplysninger
ADVARSEL:
- Læs alle instruktioner inden installationen påbegyndes.
- This product may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, current electrical codes, and/or the current National Electric Code (NEC).
- For at reducere risikoen for brand, elektrisk stød eller personskade, skal du være meget opmærksom på denne vejledning og holde dig inden for dens retningslinjer, når du bruger dette produkt.
- Sørg for, at voltage'en af din strømforsyning er kompatibel (120V AC).
- Må ikke overstige 5 AMPS maksimal belastning.
- Kun til brug med 120V 60Hz strømforsyning.
- Wiring must be completed before mounting.
- All fixtures connected to junction box must be mounted.
- Do not install in wet environments. For indoor, dry location use only.
- Kvalificerede elektrikere skal udføre alle installationer i overensstemmelse med lokale el-forskrifter.
- UL-godkendte lysdæmpere kan bruges med LED Complete (ALC-serien) dæmpbare armaturer til underskabe.
- Dette produkt er egnet til brug i dæmpningskredsløb.
- Afbryd altid strømmen til produktet, før du rengør eller monterer eller afmonterer dele.
- Brug ikke dette produkt, hvis startkablet er beskadiget.
- Hold startkablet væk fra varmekilder og varme overflader.
- Brug ikke dette produkt i miljøer, hvor der anvendes aerosolspray, eller hvor der administreres ilt.
- Til rengøring skal du bruge en blød, tør damp klæde. Brug ikke skrappe kemikalier eller slibemidler.
FORSIGTIGHED:
- To reduce the risk of electric shock, do not use this junction box or jumper cables for the ALC series (part numbers ALC-length-color) to provide power to any products other than the LED Complete fixtures (ALC Series).
- To reduce the risk of fire, electric shock, or injury to persons, do not operate fixture with missing or damaged lens or wiring compartment cover.
- To reduce the risk of electric shock or injury to persons, do not operate without end connector cover(s) in place for any molex ports/connectors not in use.
- Ikke beregnet til forsænket montering i lofter eller soffitter.
- LED'er lyser! Se ikke direkte på LED-lyskilden.
- Rør ikke ved LED'er.
- Der er ingen dele, der kan repareres inde i LED-modulet.

Image: A page from the installation instructions detailing important safety information, warnings, and pre-installation notes for the LED Complete 2 series.
Opsætning og installation
The American Lighting LED Complete 2 fixture offers flexible installation options, including direct wire and linking multiple units.
Montering af armaturet
- Bestem placeringen af hver armatur. Ved fastmonterede installationer skal forsyningskablerne tilsluttes via udslagsblanketter før montering.
- Brug en stjerneskruetrækker eller en skruetrækker til at stramme de medfølgende monteringsskruer og fastgøre beslaget til en passende monteringsflade.

Image: Diagram showing the mounting points and rear access door of the fixture. It illustrates how to secure the fixture to a surface using screws.
Connecting Power via Rear Access Door
This method is used for hardwiring the fixture directly to a power source.
- The rear access door is located in the center of the back of the fixture housing. It has its own knockout for quick connection to supply wires, foregoing the need to remove the lens cover and open the wiring compartment.
- Fjern knockout-åbningen med en hammer eller dorn, og løsn derefter skruen, der fastgør bagdøren, med en stjerneskruetrækker eller et skruetrækker.
- Install the 3/8" cable connector (included) for the supply wire following National Electric Code and local codes through this knockout on the access door. Ensure to use 14AWG or 12AWG wire. AC should be protected by circuit breaker or fuse.
- Strip back jacket on supply wires to 3/8" and use push-in connectors inside housing to connect the wires, matching polarity (Black=Black, Hot; White=White, Neutral; Yellow/Green=Bare Wire = Ground) through knockout so that push-in connectors are positioned on the housing side of the access door.
- Udskift den bagerste adgangsdør og spænd holdeskruen. Sørg for, at ledningerne ikke bliver klemt eller beskadiget af nogen del af huset eller dækslet.

Image: Detailed diagram illustrating the rear access door, knockout, and push-in wire connectors for hardwiring the fixture. It shows how to connect the electrical wires securely.
Interconnecting Fixtures
Multiple fixtures can be linked together for continuous lighting.
Interconnecting via Linking/Jumper Cable
- To interconnect nearby fixtures, remove the adjacent port covers and utilize the ALC-EX linking cable (sold separately).
- If needed, linking cables can be interconnected to make longer lengths.

Image: Diagram showing how to link multiple LED Complete 2 fixtures using an inline connector or jumper cable. It illustrates the connection points on the side of the fixtures.
Interconnecting via End-to-End Linking
For at forbinde armaturer direkte med hinanden (ende-til-ende), skal du bruge inline-stikket (inkluderet med hvert armatur) ved at fjerne tilstødende portdæksler og sætte det helt i.
Direct Wire Junction Box Installation (for ALC-BOX-##)
Denne type installation er mindre almindelig og udføres typisk kun, når den bagerste adgangsdør ikke kan bruges.
- Open wiring compartment by removing screws and open the end of the fixture cover from housing body.
- Punch out whichever knockout is best suited for connection to 120V supply wire.
- Install cable connector and connect fixture wires following National Electric Code and/or local building code requirements. Minimum 18AWG solid copper wire. AC lead should be 120V protected by circuit breaker or fuse.
- Vedhæft linje voltage supply wires to fixture lead wires with wire nuts/WAGO. White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the fixture lead wire. If your system has no ground wire, consult a qualified electrician before proceeding with the installation.
- Må ikke installeres i våde omgivelser.
- Replace the wiring compartment cover, securing with the existing retaining screws. Note: Be sure that the wires are not pinched or damaged by any part of the housing or the cover.
- Follow directions above for mounting fixture.

Image: Diagram detailing the direct wire junction box installation for the LED Complete 2 fixture. It shows the components like the junction box, electrical port, and push-in connectors, along with wiring instructions.
Betjeningsvejledning
Tænd/sluk
The fixture is equipped with a switch for basic on/off control. For hardwired installations, the fixture will operate via the wall switch connected to the circuit.
Dæmpning
The American Lighting LED Complete 2 fixture is dimmable. Use a compatible 120V dimmer switch (UL approved) for optimal performance. Refer to the "Compatible Dimmers" section for recommended models.

Image: A page from the product information showing recommended power supplies, accessories, and a table of compatible dimmers from various brands, including model numbers and dimming ranges.
Opretholdelse
Rensning
To clean the fixture, ensure power is disconnected. Use a soft, dry, or slightly damp klud. Brug ikke skrappe kemikalier, slibende rengøringsmidler eller opløsningsmidler, da disse kan beskadige overfladen eller de elektriske komponenter.
LED modul
The LED module within this fixture is not user-serviceable. Do not attempt to open or repair the LED module.
Fejlfinding
If your American Lighting LED Complete 2 fixture is not functioning as expected, please review følgende almindelige problemer og løsninger:
- Fixture does not light up:
- Kontroller om strømforsyningen er tilsluttet, og om afbryderen er slået til.
- Ensure all wiring connections are secure and correct, especially for hardwired installations.
- Verify that the fixture's on/off switch (if present) is in the "on" position.
- Bekræft, at voltage supplied is 120V AC.
- Lysudbyttet er ujævnt eller flimrer:
- Ensure a compatible dimmer switch is being used. Incompatible dimmers can cause flickering or poor dimming performance.
- Tjek for løse ledningsforbindelser.
- Armaturet er beskadiget:
- If the lens or wiring compartment cover is missing or damaged, discontinue use and contact customer support.
- Do not operate if the jumper cable is damaged.
If these steps do not resolve the issue, please contact American Lighting customer support.
Specifikationer
| Feature | Detalje |
|---|---|
| Modelnummer | ALC2-12-WH |
| Input bindtage | 120V AC 60Hz |
| Wattage | 4 watt |
| Lysstyrke | 273 lumen |
| Farvetemperatur (CCT) | 3000K (varm hvid) |
| Color Rendering Index (CRI) | 90+ |
| Dæmpbar | Yes (with compatible 120V dimmers) |
| Rated Life | 35,000 timer |
| Dimensioner (L x B x H) | 12.25 x 4 x 0.94 tommer |
| Materiale | Powder Coated Aluminum Housing, Acrylic Lens |
| Monteringstype | Surface Mounted, Under Cabinet |
| Indendørs/Udendørs brug | Kun indendørs brug |
| Certificeringer | cETLus Listed (dry location), ENERGY STAR certified |

Image: A page from the product brochure detailing technical specifications for the LED Complete 2 series, including input voltage, CCT, CRI, wattage, lumens, and rated life.
Garanti
This American Lighting product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronic parts) or, at the discretion of American Lighting, Inc., exchanged for a new or reconditioned product.
This warranty does not cover damage due to improper installation, accident, abuse, misuse, or normal wear and tear. It also does not cover incidental or consequential damages.
For complete warranty terms and conditions, please refer to the official American Lighting webwebsted eller kontakt kundesupport.
Kundesupport
For technical assistance, warranty claims, or additional information, please contact American Lighting:
- Webwebsted: www.americanlighting.com
- Adresse: 11775 E. 45th Ave. Denver, CO 80239
- Telefon: 1-800-880-1180