Produkt overview
The American Lighting ALC2-12-DB is a 12.25-inch LED undercabinet fixture in Dark Bronze, part of the LED Complete 2 Collection. This dimmable, energy-efficient fixture is designed for various installation needs, offering warm white light (3000K) with a high Color Rendering Index (CRI) of 90+. It boasts a long lifespan of up to 35,000 hours and provides high light output, being significantly brighter than traditional xenon undercabinet lights.
Its modular design allows for flexible installation with optional hardwire junction boxes, power cords, and linking cables (sold separately). The fixture features a full-length acrylic lens for even light diffusion, side power input for easy connections, and captive screws for quick mounting. Its low-profile design, under 1-inch high, ensures discreet integration under cabinets.

Image: The ALC2-12-DB LED undercabinet fixture, showcasing its slim profile and dark bronze finish.
Nøglefunktioner:
- Warm white 3000K LED light with 90+ CRI for accurate color representation.
- New design eliminates hot spots for uniform lens brightness.
- Easily link adjacent fixtures via inline connector or jumper cable (sold separately).
- Acrylic lens diffuses light evenly over the work area.
- Power input on the side for convenient cord or jumper connections.
- Lav profile design, less than 1 inch high.
- Dimmable with most CL and ELV dimmers.
- ETL Listed for indoor dry locations.
- 35,000 hours rated life.
- ENERGY STAR certified.
Vigtige sikkerhedsoplysninger
ADVARSEL: Disse produkter kan udgøre en mulig stød- eller brandfare, hvis de er forkert installeret eller fastgjort på nogen måde. Produkterne skal installeres i overensstemmelse med disse instruktioner, gældende elektriske koder og/eller den nuværende National Electric Code (NEC).
Læs alle instruktioner før du begynder. Gem disse instruktioner til fremtidig brug.
- For at reducere risikoen for brand, elektrisk stød eller personskade, skal du være meget opmærksom på denne vejledning og holde dig inden for dens retningslinjer, når du bruger dette produkt.
- Sørg for, at voltage of your power supply is compatible (120V AC).
- Do not use this junction box or jumper cables for the ALC series (part numbers ALC-length-color) to provide power to any products other than the LED Complete fixtures (ALC Series).
- CAUTION: Do not exceed 5 AMPS maximum load.
- For use with 120V 60Hz power supply only.
- WARNING: DO NOT ELECTRIFY THE JUNCTION BOX UNTIL THE FOLLOWING CONDITIONS HAVE BEEN MET:
- ALL FIXTURES CONNECTED TO JUNCTION BOX HAVE BEEN MOUNTED.
- ALL OPEN ELECTRICAL PORTS ON JUNCTION BOX AND CONNECTED FIXTURES HAVE BEEN COVERED WITH ELECTRICAL PORT COVERS PROVIDED WITH THE FIXTURE.
- WARNING: TO PREVENT OVERHEATING, DO NOT INSTALL IN SMALL, ENCLOSED SPACES. TO PREVENT ELECTRICAL SHOCK, DO NOT INSTALL IN WET ENVIRONMENTS. FOR INDOOR, DRY LOCATION USE ONLY.
- Qualified electricians in accordance with local electrical codes should perform all installations.
- UL approved dimmers may be used with the LED Complete (ALC Series) dimmable under cabinet fixtures.
- This product is suitable for use in dimming circuits.
- Always disconnect electrical power to the product before cleaning or putting on or taking off parts.
- Do not operate this product if jumper cable has been damaged.
- Keep jumper cable away from sources of heat and heated surfaces.
- Do not operate this product in environments where aerosol sprays are being used or where oxygen is being administered.
- *MOUNTING FIXTURES: See instructions supplied with the fixture, then follow instructions herein to supply power from the junction box to the fixture.
- For cleaning, use a soft, dry damp klæde. Brug ikke skrappe kemikalier eller slibemidler.
Opsætning og installation
The ALC2 LED Complete 2 Undercabinet fixture offers flexible installation options, including direct wiring or connection via accessories (sold separately).
Montering af armaturet:
- Determine locations for each fixture. For hardwire installations, connect supply wires via knockouts before mounting.
- Use a Phillips head screwdriver or driver bit to tighten captive mounting screws and secure fixture to an appropriate mounting surface.

Image: Page 1 of the installation instructions, showing mounting and wiring access.
Tilslutning af strøm:
The ALC2 fixture can be powered by an adjacent fixture using linking cables, or hardwired directly via the Hardwire Junction Box (ALC-BOX, sold separately), or powered by a 120V power cord (ALC-PC6, sold separately).
Connecting Power via Rear Access Door (Figures 1 & 2):
The rear access door is located in the center of the back of the fixture housing. It has its own knockout for quick connection to supply wires, bypassing the need to remove the lens cover and open the wiring compartment.
- Remove knockout using a hammer or punch, then loosen the screw that secures the rear access door using a Phillips head screwdriver or driver bit.
- Install the 3/8" cable connector (included) for the supply wire following National Electric Code and local codes through this knockout on the access door. Use 14AWG or 12AWG wire. AC should be protected by circuit breaker or fuse.
- Strip back jacket on supply wires to 3/8" and use push-in connectors inside housing to connect the wires, matching polarity (Black=Black, Hot; White=White, Neutral; Yellow/Green=Ground). Ensure that push-in connectors are positioned on the housing side of the access door.
- Udskift den bagerste adgangsdør og spænd holdeskruen. Sørg for, at ledningerne ikke bliver klemt eller beskadiget af nogen del af huset eller dækslet.

Image: Diagram illustrating the rear access door for wiring connections.
Connecting Power via Supply Wires Through Housing Knockouts (Figures 6 & 7):
Denne type installation er mindre almindelig og udføres typisk kun, når den bagerste adgangsdør ikke kan bruges.
- Open wiring compartment by removing screws on each end of the fixture cover from housing body.
- Punch out whichever knockout is best suited for connection to 120V supply wire. Knockouts are located along back and top of housing.
- Install cable connector and connect fixture wires following National Electric Code and/or local building code requirements. Minimum 18AWG solid copper wire. AC should be 120V protected by circuit breaker or fuse.
- Vedhæft linje voltage supply wires to fixture lead wires with wire nuts: Black to Black/Hot, White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using push-in wire connectors provided on the fixture lead wire.
- Replace wiring compartment cover, ensuring no wires are pinched.

Image: Diagram showing wiring through housing knockouts.
Direct Wire Junction Box Installation (ALC-BOX, sold separately) (Figure 1, above):
This method is used to hardwire the fixture to a power source. The ALC-BOX is designed for use with LED Complete (ALC Series) Undercabinet Lights.
- Turn off power for appropriate electrical circuit at electrical service panel.
- Remove junction box cover screws and remove cover. Save screws and lock-washers.
- Prepare flat, non-metallic cable (NM/2C+Ground) or armored cable (BX) by stripping conductor ends approximately 3/8".
- For installation using 3/8" electrical connector (junction box as shown), determine mounting orientation and remove one side knockout on desired side of junction box. Attach 3/8" electrical connector to junction box then affix 3/8" electrical connector to electrical supply (BX or NM). NM cable outer jacket must protrude through 3/8" electrical connector to adequately protect internal conductors.
- Tighten locknut and clamping screw(s) on electrical connector, fitting securely.
- Use stripped ends of wires into the push-in wire connectors (see Figure 1). Supply wires are typically color coded: Hot-black, Neutral-white, Ground-green or bare copper.
- Push excess electrical supply wire back into wall and locate the junction box on mounting surface. Affix the junction box to the underside of the cabinet with captive screws provided.
- Replace and secure junction box cover with supplied screws. Make sure lock-washers are located beneath screw heads for proper ground.
- Follow installation instructions provided with undercabinet light fixture. Mount fixture, and insert jumper wire (sold separately) or direct end-to-end connector (supplied with fixture) into appropriate electrical port of direct wire junction box.
- Make sure that all fixtures connected to junction box are properly installed and that all open electrical ports on the module and fixtures are safely covered with electrical port covers.
- Restore circuit power at electrical service panel. Turn on master switch on junction box and turn on switches for each individual fixture. Master switch can be used to control all fixtures simultaneously or fixtures can be operated individually.

Image: Diagram illustrating the components and wiring for the direct wire junction box.
Interconnecting Fixtures:
Adjacent fixtures can be linked using linking/jumper cables (ALC-EX6-BK/WH, ALC-EX12-BK/WH, sold separately) or end-to-end connectors (ALC-CON-BK/WH, sold separately).
- Via Linking/Jumper Cable: To interconnect nearby fixtures, remove the adjacent port covers and utilize the ALC-EX linking cable (sold separately) as shown in Figure 5. If needed, linking cables can be interconnected to make longer lengths.
- Via End-to-End Linking Connector: To interconnect fixtures directly to each other (end-to-end), utilize the in-line connector (included with each fixture) by removing adjacent port covers and inserting fully.

Image: Page 2 of the installation instructions, detailing linking and jumper cable connections.
Betjeningsvejledning
The American Lighting ALC2 LED Complete 2 Undercabinet fixture is designed for simple operation once installed.
Tænd/sluk:
If connected to a wall switch or the master switch on a junction box (ALC-BOX), simply use the switch to turn the fixture on or off.
Dæmpningsfunktion:
This fixture is dimmable and compatible with most CL (CFL/LED) and ELV (Electronic Low Voltage) dimmers. For optimal performance, refer to the "Compatible Dimmers" section in the specifications or consult a qualified electrician for dimmer compatibility.
Adjust the dimmer switch to achieve the desired light level. The fixture provides warm white light at 3000K.
Opretholdelse
The ALC2 LED Complete 2 Undercabinet fixture requires minimal maintenance due to its long-lasting LED technology.
Rensning:
- Always disconnect electrical power to the product before cleaning.
- Til rengøring skal du bruge en blød, tør eller damp klæde.
- Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the fixture's finish or acrylic lens.
LED -modul:
There are no serviceable parts inside the LED module. Do not attempt to open or repair the LED module yourself.
Fejlfinding
If you encounter issues with your ALC2 LED Complete 2 Undercabinet fixture, please refer to the following common troubleshooting steps:
- Fixture does not turn on:
- Ensure the electrical circuit breaker or fuse supplying power to the fixture is not tripped or blown.
- Verify that all electrical connections are secure and correctly wired according to the installation instructions.
- Check if the wall switch or any master switch controlling the fixture is in the "ON" position.
- If using a junction box, ensure the master switch on the junction box is "ON" and all electrical ports are covered.
- Lysudbyttet er ujævnt eller flimrer:
- Ensure the dimmer switch (if installed) is compatible with LED fixtures and is set correctly. Incompatible dimmers can cause flickering.
- Check all linking cable connections between fixtures to ensure they are secure.
- Fixture is damaged:
- Do not operate the product if the jumper cable or any part of the fixture has been damaged. Contact customer support for assistance.
- Fixture is too hot:
- Ensure the fixture is not installed in a small, enclosed space that could lead to overheating. Adequate ventilation is required.
For issues not resolved by these steps, please contact American Lighting customer support.
Specifikationer

Image: Diagram showing ordering information, available sizes, finishes, and compatible accessories.
| Attribut | Værdi |
|---|---|
| Mærke | Amerikansk belysning |
| Modelnavn | LED Complete 2 Collection |
| Varenummer | ALC2-12-DB |
| Farve | Mørk bronze |
| Størrelse | 12 inches (12.25 x 4 x 0.94 inches) |
| Materiale | Glass, Acrylic (Shade) |
| Stil | 1-pakke |
| Værelsestype | Køkken |
| Indendørs/Udendørs brug | Indendørs |
| Strømkilde | Corded Electric (accessories sold separately) |
| Installationstype | Surface Mount, Under Cabinet |
| Speciel funktion | Dæmpbar |
| Kontrolmetode | Touch (via compatible dimmer) |
| Lyskildetype | LED |
| Finish Type | Bronze |
| Antal lyskilder | 2 |
| Voltage | 120 volt |
| Lys farve | Varm hvid (3000K) |
| Wattage | 4 watt |
| Lysstyrke | 238 lumen |
| Effektivitet | 59.5 lumen pr watt |
| Rated Life | 35,000 timer |
| UPC | 714176005461 |
Kompatible lysdæmpere:
| Mærke | Model # | Type | Dæmpningsområde |
|---|---|---|---|
| Lutron Diva | DVCL-153P | Universal (CFL/LED/Incandescent) | 5-100 % |
| Lutron Diva | DVELV-300P | Elektronisk lav voltage (ELV) | 5-100 % |
| Lutron Sureslide | 6613 | Magnetic Low Voltage (MLV) | 5-100 % |
Note: Dimmer performance may vary in field application due to unknown external factors. Dimmers not included on the chart above are not necessarily incompatible; they have yet to be fully evaluated. Please reference dimmer manufacturer's instructions for more detailed information regarding performance and compatibility.
Garantioplysninger
5-Year Limited Product Warranty:
This product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. This warranty applies to the fixture during this period and will be either repaired (i.e. replacement of defective electronic components) or replaced (i.e. replacement of the entire fixture, lamp sockets, excluding the lamp) or replaced, at the discretion of American Lighting, Inc. Claims for defective products must be submitted to the retail store from which the product was purchased to obtain warranty. Upon submission of proper return claim documentation and product to American Lighting, Inc. by the retailer, American Lighting, Inc. will reserve the right to inspect the product for misuse or abuse. Claims for defects or inconveniences of products that are not an American Lighting, Inc. original product will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc. shall have no liability whatsoever for incidental or consequential damages, including without limitations, installation costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or attached in any way. This warranty applies only to products that have been installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situations where components have been altered in any way.
For questions, comments, technical assistance or an inquiry, please call toll free at: 1-800-285-8051 (M-F 8am - 5pm, MST).
Kundesupport
For further assistance, technical support, or warranty claims, please contact American Lighting:
- Telefon: 1-800-285-8051 (Monday - Friday, 8:00 AM - 5:00 PM MST)
- Webwebsted: www.americanlighting.com
- Amazon Store: Visit the American Lighting Store on Amazon
Please have your product model number (ALC2-12-DB) and purchase information ready when contacting support.