1. Introduktion
This manual provides essential instructions for the safe and effective operation, maintenance, and troubleshooting of the Woods DMMW3 Pocket Digital Multimeter. The DMMW3 is a compact, versatile tool designed for various electrical measurements, featuring 10 test functions suitable for home repairs and general electrical testing.
2. Sikkerhedsoplysninger
WARNING: Read and understand all safety information and operating instructions in this manual before using the Woods DMMW3 Pocket Digital Multimeter. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always inspect the multimeter and test leads for damage before use. Do not use if damaged.
- Sørg for, at funktionskontakten er i den korrekte position for den måling, der udføres.
- Do not exceed the maximum input limits for any function: CAT III 300V, CAT II 600V.
- Vær forsigtig, når du arbejder med voltagover 30V AC RMS, 42V peak eller 60V DC, da disse udgør en risiko for stød.
- Do not operate the meter with the battery cover removed or loosened.
- Udskift batteriet med det samme, når indikatoren for lavt batteri vises, for at sikre nøjagtige aflæsninger.
- Disconnect test leads from the circuit before changing functions.
- The current input is fused (200mA MAX FUSED). Do not attempt to measure currents exceeding this rating.
3. Pakkens indhold
Bekræft at alle genstande er til stede og ubeskadigede:
- Woods DMMW3 Pocket Digital Multimeter
- Testledninger (røde og sorte)
- CR2032 Battery (may be pre-installed or included separately)
- Brugervejledning (dette dokument)
4. Produktet er slutview
Familiarize yourself with the components of your DMMW3 multimeter:

Figur 1: Forside view of the Woods DMMW3 Pocket Digital Multimeter. The image shows the digital display, function selector dial, and control buttons (MODE, RANGE, HOLD, MAX).
- Digital skærm: Shows measurement readings, units (DC, AC, nF, µF, V, A, MΩ, kΩ, Hz, %), and indicators (AUTO, HOLD, low battery).
- Funktionsvælger: Rotary switch to select primary measurement functions (mA, Ω/Continuity/Diode/Capacitance, V, Hz%).
- MODE knap: Toggles between different measurement types within a selected function (e.g., AC/DC voltage, resistance/continuity/diode/capacitance).
- RANGE knap: Manually selects measurement range (if not in auto-ranging mode).
- HOLD knap: Fryser den aktuelle displayaflæsning.
- MAX knap: Displays the maximum reading recorded during a measurement session.
- Indgangsstik:
- COM (Common) Jack: For the black test lead.
- VΩHz%mA Jack: For the red test lead when measuring voltage, resistance, frequency, capacitance, or current (up to 200mA).
5. Opsætning
5.1 Batteriinstallation
The DMMW3 uses one CR2032 coin cell battery. If the low battery indicator appears on the display, or if the unit does not power on, replace the battery:
- Ensure the multimeter is powered off and disconnect all test leads.
- Find batterirummet på bagsiden af enheden.
- Use a small screwdriver to open the battery compartment cover.
- Remove the old CR2032 battery, noting its polarity.
- Indsæt et nyt CR2032-batteri med den positive (+) side opad.
- Sæt batterirummets dæksel på igen og fastgør det med skruen.
5.2 Tilslutning af testledninger
Always connect the test leads correctly for accurate and safe measurements:
- Indsæt den sorte testledning i KOM (Fælles) indgangsstik.
- Indsæt den røde testledning i VΩHz%mA input jack for most measurements (voltage, resistance, continuity, diode, capacitance, frequency, current up to 200mA).
6. Betjeningsvejledning
6.1 Tænd/sluk
To power on the multimeter, rotate the Function Selector Dial from the OFF position to any desired measurement function. To power off, rotate the dial back to the OFF position (indicated by the power symbol ⏻).
6.2 Funktionsvalg
Rotate the Function Selector Dial to choose the primary measurement category:
- mA: For measuring DC or AC current (up to 200mA).
- Ω / Continuity / Diode / Capacitance: For measuring resistance, checking continuity, testing diodes, or measuring capacitance. Use the MODE button to cycle through these functions.
- V: For measuring DC or AC voltage. Brug MODE button to switch between DC and AC voltage.
- Hz %: For measuring frequency or duty cycle. Use the MODE button to switch between frequency (Hz) and duty cycle (%).
6.3 Using Control Buttons
- KØRSELSVEJLEDNING: Press to select secondary functions within a dial position (e.g., AC/DC, Resistance/Continuity/Diode/Capacitance, Hz/%).
- RÆKKEVIDDE: Tryk for at skifte mellem automatisk og manuel områdeindstilling. Tryk gentagne gange på tast for at gennemgå de tilgængelige områder i manuel områdeindstilling.
- HOLDE: Tryk for at fryse den aktuelle aflæsning på displayet. Tryk igen for at slippe.
- MAKS: Press to capture and display the maximum value measured during a session. Press again to exit MAX mode.
6.4 Performing Measurements (Examplæs)
Always ensure the circuit is de-energized before connecting test leads for resistance, continuity, diode, or capacitance measurements.
6.4.1 DC/AC Voltage Måling
- Set the Function Selector Dial to V.
- Tryk på MODE button to select DC or AC voltage (DC or AC indicator on display).
- Connect the red test lead to the positive (+) side of the circuit and the black test lead to the negative (-) side or ground.
- Læs bindtage -værdi på displayet.
6.4.2 Modstandsmåling
- Sørg for, at kredsløbet er spændingsløst.
- Set the Function Selector Dial to Ω. Trykke MODE until the Ω symbol is displayed.
- Tilslut testledningerne på tværs af den komponent, der skal måles.
- Læs modstandsværdien på displayet.
6.4.3 Kontinuitetstest
- Sørg for, at kredsløbet er spændingsløst.
- Set the Function Selector Dial to Ω. Trykke MODE until the continuity symbol (⧸) vises.
- Tilslut testledningerne på tværs af kredsløbet eller komponenten.
- A continuous beep indicates continuity (low resistance). The display will show the resistance value.
7. Vedligeholdelse
7.1 Rengøring
Tør sagen af med annonceamp cloth and mild detergent. Do not use abrasives or solvents. Keep the input terminals free of dirt and moisture.
7.2 Udskiftning af batteri
Refer to Section 5.1 for detailed battery replacement instructions. Always use a fresh CR2032 battery.
7.3 Udskiftning af sikringer
The DMMW3 has a 200mA MAX FUSED input for current measurements. If the current measurement function stops working, the fuse may need replacement. This procedure should only be performed by qualified personnel.
- Ensure the multimeter is powered off and disconnect all test leads.
- Open the back casing of the multimeter (this may require removing multiple screws).
- Locate the fuse.
- Replace the blown fuse with a fuse of the exact same type and rating (e.g., 200mA, fast-acting).
- Carefully reassemble the multimeter, ensuring all screws are tightened.
WARNING: Using an incorrect fuse type or rating can damage the meter and pose a serious safety hazard.
7.4 Opbevaring
If the meter is not to be used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Måleren tænder ikke. | Dødt eller forkert installeret batteri. | Check battery polarity; replace battery (CR2032). Refer to Section 5.1. |
| Ingen aflæsning eller "OL" (Overbelastning) vises. | Forkert funktion valgt; åbent kredsløb; målingen overskrider området. | Verify function dial setting; check circuit continuity; switch to a higher range if available or use auto-ranging. |
| Upræcise aflæsninger. | Low battery; poor test lead connection; external interference. | Replace battery; ensure secure lead connections; move away from strong electromagnetic fields. |
| Current measurement not working. | Sprunget sikring. | Replace the 200mA fuse. Refer to Section 7.3. |
9. Specifikationer
| Feature | Detalje |
|---|---|
| Modelnummer | DMMW3 |
| Mærke | Southwire (Woods) |
| Målefunktioner | Voltage (AC/DC), Current (DC/AC), Resistance, Continuity, Diode, Capacitance, Frequency, Duty Cycle |
| Sikkerhedsvurdering | CAT III 300V, CAT II 600V |
| Strømindgangssikring | 200mA MAX FUSED |
| Strømkilde | 1 x CR2032 batteri |
| Vise | Digital LCD |
| Varens vægt | 6.4 ounces (ca. 181 g) |
| Pakkedimensioner | 9 x 5 x 3 tommer (ca. 22.86 x 12.7 x 7.62 cm) |
| Oprindelsesland | Kina |
| Dato først tilgængelig | 27. april 2016 |
10. Garanti og support
For warranty information or technical support regarding your Woods DMMW3 Pocket Digital Multimeter, please contact Southwire customer service. Retain your proof of purchase for warranty claims.
Manufacturer: Southwire
Kontaktoplysninger kan typisk findes på producentens officielle webwebsted eller produktemballage.