1. Introduktion
This manual provides detailed instructions for the installation, operation, and maintenance of your HQST 20A PWM Solar Charge Controller. This device is designed to manage the power flow from your solar panel to your battery, ensuring efficient charging and protecting your battery from overcharge and over-discharge. It is compatible with 12V and 24V PV systems and various lead-acid battery types.
2. Produktfunktioner
- 20A solcelleladningsregulator: Automatically detects 12V or 24V PV systems.
- Batterikompatibilitet: Works with Sealed, and Flooded lead-acid batteries.
- Optimeret opladning: Features an optimized 3-stage battery charging system to regulate electricity flow and prolong battery lifespan.
- Accurate LCD Display: Large digital LCD display clearly indicates working conditions and accurate operating data for real-time PV system monitoring.
- Omfattende beskyttelse: Provides reverse polarity protection, block reverse current at night, short circuit, overcharge, over-discharge, and overload protection for solar panel and battery.
- Nem installation: Designed with corresponding icons on each connector for quick setup.
- USB-A-port: Includes a USB-A port for charging mobile devices or powering small loads.
- Flere applikationer: Suitable for RVs, cabins, workshops, garages, and other off-grid lighting or power needs.
3. Produktet er slutview
Familiarize yourself with the components of your HQST Solar Charge Controller.

Figur 3.1: Front view of the HQST Solar Charge Controller with key components labeled, including mounting holes, LCD screen, control keys, solar panel terminals, battery terminals, load terminals, and USB port.

Figur 3.2: Detaljeret view of the LCD display, showing indicators for PV (solar panel), BAT (battery), LOAD, parameter digits, and units (kWh, %, V, °C). It also illustrates the power flow from solar panel to battery to load.
4. Specifikationer
| Feature | Specifikation |
|---|---|
| Model | 20A PWM |
| System Voltage | 12V / 24V Auto |
| Max ladestrøm | 20A |
| Batteritypekompatibilitet | Sealed, Flooded Lead-Acid Batteries |
| Display Type | LCD |
| USB udgang | 5V/1A (USB-A Port) |
| Produktdimensioner | 5.12 x 1.38 x 2.95 tommer (13 x 3.5 x 7.5 cm) |
| Varens vægt | 4.9 ounce (0.14 kg) |
| Fabrikant | HQST |
| UPC | 791810331544, 810081407366 |

Figur 4.1: Physical dimensions of the HQST Solar Charge Controller, showing length (6.45 in), width (4.07 in), and height (1.85 in).

Figur 4.2: Illustration of battery types compatible with the HQST Solar Charge Controller, including Sealed, Gel, Flooded, and Lead-Acid batteries.
5. Sikkerhedsinstruktioner
- Ensure all connections are tight and secure to prevent loose connections that can cause excessive heat.
- Tilslut altid batteriet til laderegulatoren først, derefter solpanelet og til sidst belastningen. Frakobl i omvendt rækkefølge.
- Do not connect an inverter directly to the load terminals of the charge controller. Connect inverters directly to the battery.
- Installer controlleren i et godt ventileret område, væk fra direkte sollys, høje temperaturer og fugt.
- Sørg for, at systemet voltage (12V or 24V) matches the battery bank voltage. The controller automatically detects this.
- Brug passende ledningstykkelser til alle forbindelser for at forhindre vol.tage drop og overophedning.
- Brug øjenbeskyttelse, når du arbejder med batterier.
6. Installation (Opsætning)
Follow these steps for proper installation of your solar charge controller.
- Montering: Choose a dry, well-ventilated location for mounting the controller. Ensure there is sufficient space around the controller for heat dissipation. Use the mounting holes provided on the unit.
- Tilslut batteriet: Connect the battery to the battery terminals on the charge controller. Ensure correct polarity (+ to + and - to -). The LCD display should illuminate, indicating the controller has detected the battery voltage.
- Tilslut solpanelet: Connect the solar panel to the solar panel terminals on the charge controller. Ensure correct polarity. The controller will begin charging the battery if sunlight is available.
- Tilslut belastningen: Connect your DC loads (e.g., lights, fans) to the load terminals. Ensure correct polarity. The USB-A port can also be used for charging compatible devices.
Important Connection Order: Always connect the battery first, then the solar panel, and finally the load. Disconnect in the reverse order: load first, then solar panel, then battery.

Figur 6.1: A typical wiring diagram showing the connection of a 12V solar panel, the HQST PWM charge controller, a 12V deep cycle battery, and a 12V power inverter. Note the recommended fuse placement and wire gauges.

Figur 6.2: Visual step-by-step guide for connecting the HQST Solar Charge Controller: 1. Connect the battery. 2. Connect the solar panel. 3. Connect the load (light bulb). This sequence ensures safe and proper system setup.
7. Betjening
Once installed, the controller operates automatically. The LCD display provides real-time information about your system.
7.1 LCD-display og knapfunktioner
The LCD cycles through various parameters such as battery voltage, charging current, load current, and temperature. The single red button is used to manually cycle through display modes or to enter settings for load control (e.g., timer settings for lights).
- Kort tryk: Cycles through display parameters.
- Langt tryk (ca. 5 sekunder): Enters or exits setting mode for load control.
7.2 Belastningskontrol
The controller offers programmable load control. You can set the load to turn on/off based on daylight or a timer. Refer to the specific settings menu on the LCD for detailed configuration. The USB-A port is typically powered when the load output is active.

Figur 7.1: The HQST Solar Charge Controller featuring a USB-A port, which can be used to charge mobile devices or power small USB-compatible electronics.
8. Vedligeholdelse
Regelmæssig vedligeholdelse sikrer optimal ydeevne og levetid for din solcelleladeregulator.
- Undersøg forbindelser: Periodically check all wiring connections for tightness and corrosion. Loose connections can lead to power loss and overheating.
- Rengør controlleren: Hold controlleren ren og fri for støv og snavs. Brug en tør klud til rengøring. Brug ikke væsker.
- Overvåg ydeevne: Regularly check the LCD display for normal operation and expected readings. Note any unusual behavior.
- Batteriets sundhed: Ensure your batteries are properly maintained according to their manufacturer's guidelines.
9. Fejlfinding
Dette afsnit omhandler almindelige problemer, du kan støde på med din solcelleladeregulator.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Controlleren tænder ikke / LCD-skærmen er tom | Battery not connected or reverse polarity; battery voltage for lavt. | Kontroller batteriforbindelser og polaritet. Sørg for batterivolumen.tage er over minimumsdriftsvolumentage (typisk 8V). |
| Batteriet oplades ikke | Solar panel not connected or reverse polarity; insufficient sunlight; damaged solar panel or wiring. | Check solar panel connections and polarity. Ensure adequate sunlight. Inspect solar panel and wiring for damage. |
| Indlæsningen virker ikke | Load not connected or reverse polarity; load current exceeds controller rating; battery voltage too low; load control setting. | Check load connections and polarity. Ensure load current is within 20A. Check battery voltage. Adjust load control settings if a timer or light sensor mode is active. |
| Fejlkoder på LCD-skærmen | Specific system fault (e.g., overcharge, over-discharge, short circuit). | Refer to the controller's internal error code list (if available in a more detailed manual) or contact HQST support. Address the underlying issue (e.g., reduce load, check battery). |
10. Garanti og support
For warranty information or technical support, please refer to the official HQST webwebstedet eller kontakt deres kundeservice direkte. Gem din købskvittering til garantikrav.
HQST is committed to providing high-quality solar products and responsive customer service.