1. Introduktion
Thank you for choosing the Numeric Digital 1000 HPH UPS. This Uninterruptible Power Supply (UPS) is designed to provide reliable power backup and protection for your electronic devices. It features constant current and short circuit protection, ensuring the safety and longevity of your connected equipment. This manual provides essential information for the proper installation, operation, and maintenance of your UPS.
2. Vigtige sikkerhedsinstruktioner
Please read and follow all instructions carefully before installing and operating the UPS. Keep this manual for future reference.
- Åbn ikke UPS'en casing. Der er ingen dele indeni, som brugeren kan servicere. Overlad al service til kvalificeret servicepersonale.
- Installer ikke UPS'en i direkte sollys, i nærheden af varmekilder eller i områder med meget støv, fugtighed eller ætsende stoffer.
- Sørg for tilstrækkelig ventilation omkring UPS'en. Bloker ikke ventilationsåbningerne.
- Tilslut kun UPS'en til en jordet vekselstrømsstikkontakt.
- Do not connect appliances that could overload the UPS, such as laser printers or vacuum cleaners.
- I tilfælde af brand, brug en tørkemisk brandslukker. Vand kan forårsage elektrisk stød.
- Disconnect the UPS from the AC power outlet before cleaning. Use a dry cloth for cleaning.
3. Pakkens indhold
Carefully unpack the UPS and check if all items are included:
- 1 x Numeric Digital 1000 HPH UPS Unit
- 1 x Brugermanual (dette dokument)
- 1 x Power Cord (if applicable)
4. Nøglefunktioner
- Model: Numeric Digital 1000 HPH
- Farve: Sort
- Wattage: 600 W
- Dimensioner (L x B x H): Cirka 28 cm x 22 cm x 8 cm
- Input bindtage: 230 V
- Udgang Voltage: 230 V
- Formfaktor: Rack (Compact)
- Beskyttelse: Konstant strøm og kortslutningsbeskyttelse
- Oprindelse: Fremstillet i Indien
5. Opsætning og installation
5.1 Udpakning og placering
Unpack the UPS and place it on a flat, stable surface. Ensure there is adequate space around the unit for ventilation. Avoid placing it near heat sources or in direct sunlight.

Figur 5.1: Vinklet view of the Numeric Digital 1000 HPH UPS, showing its compact black casing and ventilation grilles.
5.2 Tilslutning af UPS'en
Before connecting any devices, ensure the UPS is turned off. Connect the UPS to a grounded wall outlet using the provided power cord. Then, connect your computer, monitor, and other essential peripherals to the output sockets on the rear of the UPS.

Figure 5.2: Rear panel of the UPS, illustrating the input protector, input power connection, and multiple output sockets for connecting devices. Also visible are switches for 'Narrow' and 'Wide' voltage rækkeviddeindstillinger.
Input Protector: This is a resettable circuit breaker that protects the UPS from input overcurrent. If it trips, press it to reset after resolving the issue.
Udgangsstik: Connect your devices to these sockets. Ensure the total wattage of connected devices does not exceed the UPS's capacity (600W).
Voltage Range Switch (Narrow/Wide): This switch allows you to select the acceptable input voltage range. "Narrow" typically provides more precise voltage regulation, while "Wide" allows the UPS to operate in environments with larger voltage fluctuations before switching to battery power. Consult your local power conditions to choose the appropriate setting.
6. Betjening
6.1 Turning On/Off the UPS
To turn on the UPS, press and hold the power button on the front panel for a few seconds until you hear a beep and the indicators light up. To turn off the UPS, press and hold the power button again until the indicators turn off.

Figure 6.1: Front panel of the UPS, displaying the power button and a series of indicator lights that provide status information.
6.2 Indikatorlys
The front panel features several indicator lights to show the operational status of the UPS:
- Indikator for AC-tilstand: Lights up when the UPS is operating on utility power.
- Battery Mode Indicator: Lights up when the UPS is operating on battery power (during a power outagog).
- Fejl-/advarselsindikator: Lights up to indicate a fault condition or warning (e.g., overload, battery low). Refer to the troubleshooting section for details.
- Batteriniveauindikator: Shows the approximate charge level of the internal battery.
6.3 Power Protection Features
The Numeric Digital 1000 HPH UPS provides:
- Constant Current Protection: Ensures a stable current supply to connected devices, protecting them from fluctuations.
- Kortslutningsbeskyttelse: Automatically shuts down the UPS in case of a short circuit to prevent damage to the unit and connected equipment.
7. Vedligeholdelse
Korrekt vedligeholdelse sikrer din UPS' levetid og optimal ydeevne.
- Batteripleje: To maximize battery life, avoid frequent deep discharges. It is recommended to fully discharge and recharge the UPS battery once every three months if it's not frequently used.
- Rensning: Tag UPS'en ud af stikkontakten før rengøring. Brug en blød, tør klud til at tørre ydersiden af. Brug ikke flydende rengøringsmidler eller rengøringsmidler på sprayform.
- Ventilation: Ensure that the ventilation openings on the UPS are clear of dust and obstructions to prevent overheating.
- Opbevaring: If storing the UPS for an extended period, ensure the battery is fully charged, then disconnect it from the power source. Recharge the battery every 3-6 months to prevent battery degradation.
8. Fejlfinding
This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| UPS'en tænder ikke. | No AC input power; Battery discharged; Power button not pressed correctly. | Check AC power cord connection; Allow UPS to charge for several hours; Press and hold the power button firmly. |
| UPS beeps continuously or indicator lights flash. | Overload; Low battery; Internal fault. | Reduce connected load; Allow battery to recharge; If fault persists, contact service. |
| UPS'en skifter ofte til batteritilstand. | Unstable utility power; Input voltage range setting is too narrow. | Check utility power quality; Try switching the voltage range to "Wide" on the rear panel. |
| Battery backup time is shorter than expected. | Batteriet er gammelt eller ikke fuldt opladet; Overbelastet. | Allow battery to fully charge; Reduce connected load; Consider battery replacement if old. |
9. Tekniske specifikationer
| Mærke | Numerisk |
| Model | Digital 1000 HPH |
| Fabrikant | Numeric Power System |
| Varemodelnummer | Digital 1000 HPH |
| Wattage | 600 watt |
| Input bindtage | 230 volt |
| Udgang Voltage | 230 volt |
| Dimensioner (L x B x H) | 28 cm x 22 cm x 8 cm |
| Farve | Sort |
| Formfaktor | Rack (Compact) |
| Connector Type | IEC 320 |
| ASIN | B01AG9UJC8 |
| Dato først tilgængelig | 11 januar 2016 |
10. Garanti og support
For detailed warranty information, please refer to the warranty card included with your product or visit the official Numeric website. For technical support, service, or inquiries, please contact Numeric customer service through their official channels.
Note: This manual provides general guidance. Specific warranty terms and support contact details may vary by region and are subject to change.