Intermatic EP100C

Intermatic EP100C 24-timers 1-kreds elektronisk styringsvejledning

Model: EP100C

Indledning

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Intermatic EP100C 24-Hour 1 Circuit Electronic Control. This device is designed for precise control of electrical circuits, offering reliable scheduling for various applications.

Vigtige sikkerhedsoplysninger

FORSIGTIG: RISIKO FOR ELEKTRISK STØD. More than one disconnect switch may be required to de-energize the equipment before servicing. Use 10-18 gauge copper conductors rated for at least 75°C (167°F) for all connections.

FORSIGTIGHED: RIESGO DE DESCARGA ELECTRICA. La instalación de varios interruptores de desconexión podría ser necesaria a fin de desactivar el equipo antes de llevar a cabo la reparación. Utilice conductores de cobre tamaño 10-18 conducidos con una especificación de al menos 75°C (167°F) para todas las conexiones.

Always disconnect power at the circuit breaker or fuse box before installing or servicing the control. Ensure all wiring is performed by a qualified electrician and complies with local and national electrical codes.

Opsætning og installation

The Intermatic EP100C is designed for indoor/outdoor use and comes in a plastic enclosure. Follow these steps for proper installation:

1. Montering

Securely mount the enclosure in a suitable location, ensuring it is protected from direct impact and excessive vibration. Use appropriate fasteners for the mounting surface.

2. Ledninger

Before wiring, ensure all power to the circuit is disconnected. The unit features terminals for Timer Power, Line 1, and Load 1. Refer to the internal diagram for correct connections.

Intermatic EP100C Electronic Control internal view with wiring terminals and display

Figur 1: Intern View of Intermatic EP100C. This image shows the internal components of the EP100C electronic control, including the digital display, control buttons (MODE, RESET, ENTER NEXT, ON/OFF), and the wiring terminals labeled TIMER POWER, LINE 1, and LOAD 1. A battery compartment is also visible. Important safety warnings regarding electrical shock and conductor specifications are printed on the internal cover.

  • Timer Power (1, 2): Connect the incoming power supply to these terminals.
  • Line 1 (3): Connect the incoming hot wire for the controlled circuit.
  • Load 1 (4): Connect the wire leading to the device being controlled.

DO NOT REMOVE THIS INSULATOR: To wire, lift and swing the insulator. Replace it after wiring to ensure proper insulation and safety.

3. Strømforsyning Voltage Valg

The unit supports 120-277 VAC. There is a mechanism inside to select the timer power supply voltage. Ensure this is set correctly for your application before applying power.

4. Batteriinstallation

Install the backup battery (type not specified, typically coin cell or AA/AAA) into the designated battery compartment. This battery maintains program settings during power outages.

Betjeningsvejledning

The EP100C features a digital display and several control buttons for programming and manual operation.

1. Initial Setup and Time/Date Setting

  1. Tryk på MODE knappen for at åbne opsætningsmenuen.
  2. Brug ENTER NEXT button to navigate through time, date, and other settings.
  3. Brug + og - buttons (up/down arrows) to adjust values.
  4. Confirm each setting by pressing ENTER NEXT.

2. Programming ON/OFF Events

  1. Trykke MODE until you reach the program setting mode.
  2. Bruge ENTER NEXT to select a program slot (e.g., P1 ON, P1 OFF).
  3. Set the desired ON time using the + og - knapper.
  4. Trykke ENTER NEXT to save and move to the OFF time.
  5. Repeat for the OFF time.
  6. Fortsæt med yderligere programmer efter behov.

3. Manuel tilsidesættelse

Tryk på ON/OFF button to manually switch the controlled circuit ON or OFF, overriding the current program until the next scheduled event.

4. Resetting and Clearing Memory

  • Trykke NULSTIL to perform a full system reset, clearing all settings and programs.
  • Trykke Clear Mem (Clear Memory) to erase programmed events without resetting the time/date.
  • Trykke Ryd indtastning to clear the current input during programming.

Opretholdelse

Udskiftning af batteri

The internal battery should be replaced periodically to ensure program retention during power outages. When the battery is low, an indicator may appear on the display. Disconnect power before replacing the battery.

Fejlfinding

ProblemMulig årsagLøsning
Skærmen er tomNo power to the unit; dead backup battery.Check circuit breaker. Ensure wiring is correct. Replace backup battery.
Load does not turn ON/OFF as programmedIncorrect program settings; manual override engaged; wiring issue.Verify program times. Check if manual override is active. Inspect load wiring.
Unit resets unexpectedlyPower fluctuation; faulty battery.Ensure stable power supply. Replace backup battery.

Specifikationer

  • Model: EP100C
  • Type: 24-Hour 1 Circuit Electronic Control
  • Voltage: 120-277 VAC
  • Frekvens: 60 Hz
  • Switch Type: SPST (Single Pole Single Throw)
  • Indkapsling: Indoor/Outdoor Plastic Enclosure
  • Dimensioner: 9.5 x 5.75 x 3.75 tommer
  • Vægt: 4 ounce

Støtte

For further assistance or technical support, please contact Intermatic customer service. Refer to the official Intermatic website for contact information and warranty details.

Relaterede dokumenter - EP100C

Preview Intermatic ET8215C Elektronisk Timerstyring - Tekniske Data
Detaljerede tekniske specifikationer for Intermatic ET8215C elektronisk timerstyring, en astronomisk 7-dages, 2-kreds elektronisk styring egnet til 120-277 VAC applikationer i et indendørs metalkabinet.
Preview Intermatic T104 24-timers tidsafbryder - Specifikationer og instruktioner
Omfattende vejledning til Intermatic T104 24-timers tidsafbryder med detaljerede specifikationer, elektriske klassificeringer, sikkerhedsadvarsler, ledningsføringsinstruktioner, programmeringsprocedurer og betjeningsvejledning. Indeholder tekniske data og tips til fejlfinding.
Preview Intermatic KM2 Series In-Wall Timer: Installation and Operating Instructions
Comprehensive guide for installing and operating the Intermatic KM2 Series In-Wall Timers. Learn about features, specifications, programming, and wiring for automatic control of lighting and other circuits.
Preview Intermatic EJ351 Indoor Wall Switch Timer: Installation and User Instructions
This document provides installation and user instructions for the Intermatic EJ351 Indoor Wall Switch Timer. It covers specifications, wiring, programming methods (Rapid and 24-Hour), everyday use, troubleshooting, and a one-year limited warranty.
Preview Intermatic DTAV40E2-serien: Indstilling af klokkeslæt og programmering af begivenheder
En vejledning til indstilling af klokkeslæt, ugedag og programmering af tænd/sluk-hændelser for den elektroniske timer i Intermatic DTAV40E2-serien.
Preview Intermatic ET100-seriens elektroniske 24-timers tidsafbryder bruger-/installationsmanual
Omfattende bruger- og installatørvejledning til Intermatic ET100-seriens elektroniske 24-timers tidsafbrydere, inklusive modellerne ET102C, ET102CM, ET104C og ET104CM. Dækker installation, programmering, fejlfinding og garantioplysninger.