1. Introduktion
This manual provides essential information for the safe and efficient operation of your SUNGOLDPOWER 12000W 48V Split Phase Pure Sine Wave Inverter Charger. Please read this manual thoroughly before installation and use to ensure proper function and to prevent damage to the unit or connected equipment.
1.1 Sikkerhedsoplysninger
WARNING: This device operates with high voltages and currents. Improper installation or use can result in serious injury, death, or equipment damage. All electrical work should be performed by qualified personnel in accordance with local electrical codes.
- Sørg for, at inverteren er installeret i et godt ventileret område, væk fra brandfarlige materialer.
- Do not expose the inverter to water or excessive moisture.
- Always disconnect all power sources (AC and DC) before performing any maintenance or wiring.
- Sørg for korrekt jording af inverteren.
- Do not attempt to disassemble or repair the inverter yourself. Refer to qualified service personnel.
2. Produktet er slutview og funktioner
The SUNGOLDPOWER 12000W 48V Inverter Charger is a robust, low-frequency pure sine wave inverter designed for off-grid power systems. It integrates an inverter, an AC battery charger, and an automatic transfer switch into a single unit.

Figur 2.1: Forside view of the SUNGOLDPOWER 12000W 48V Inverter Charger, showing the display panel.
2.1 Nøglefunktioner
- Strømudgang: 12,000 Watts continuous, 36,000 Watts peak for 20 seconds.
- Input/output: DC 48V input, AC 240V input, AC 120/240V split phase pure sine wave output.
- Integreret oplader: 80 Amp AC battery charger with multi-stage opladning.
- Overførselskontakt: Automatic transfer switch for seamless switching between AC sources (utility/generator) and battery power.
- Batterikompatibilitet: Supports AGM, Gel, Lead Acid, Lithium-ion, and LiFePO4 batteries.
- Justerbare indstillinger: User-adjustable charge current (0-100%) and DIP switch settings for utility/battery priority and low voltage afskæring.
- Automatic Generator Start (AGS): Feature for automatic generator activation.
- Beskyttelsesfunktioner: Over/lav voltage protection, over temperature protection, and overload protection.
- Fjernovervågning: Includes a remote control with a 32-foot cable for convenient monitoring and control.
- Temperatursensor: Battery temperature sensor with a 32-foot cable to protect batteries from overheating during charging.
- Ansøgninger: Suitable for various applications including homes, cabins, offices, RVs, trailers, and boats.

Figure 2.2: Visual representation of the inverter's key features, including 12KW split phase output, battery temperature sensor, remote control, auto generator start, low frequency industrial grade design, and broad compatibility with appliances and batteries.
3. Pakkens indhold
Ved udpakning skal du kontrollere, at alle nedenstående varer er til stede og ubeskadigede:
- SUNGOLDPOWER 12000W 48V Split Phase Inverter Charger (1 unit)
- Remote Control with 32-foot cable (1 set)
- Battery Temperature Sensor with 32-foot cable (1 set)
- Brugervejledning (dette dokument)

Figure 3.1: Included accessories with the SUNGOLDPOWER Inverter Charger.
4. Specifikationer
| Specifikation | Værdi |
|---|---|
| Modelnummer | I12000S4812024060HCCAMSG2 |
| Kontinuerlig kraft | 12000 watt |
| Peak Power (20s) | 36000 watt |
| DC Input Voltage | 48V |
| AC -indgang Voltage | 240V |
| AC Output Voltage | 120V/240V Split Phase |
| Output bølgeform | Ren Sine Wave |
| AC Battery Charger Current | 80 Amps |
| Produktdimensioner | 27.6 x 16.5 x 7.9 tommer |
| Varens vægt | 197.1 pund |
| Fabrikant | SUNGOLDPOWER |
| Anbefalede anvendelser | Home, Office, RV, Trailer, Boat, Workshop |
| Strømkilde | Batteridrevet |
5. Installation og opsætning
Proper installation is critical for the safety and performance of your inverter charger. Consult a qualified electrician if you are unsure about any steps.
5.1 Monteringssted
- Mount the inverter on a sturdy, non-flammable surface.
- Ensure adequate ventilation around the unit to prevent overheating. Maintain clear space around all vents.
- Avoid locations exposed to direct sunlight, high temperatures, dust, or moisture.
5.2 Ledningsforbindelser
Refer to the wiring diagram below for proper connection of solar panels (if applicable), MPPT solar controller, battery bank, AC input (utility or generator), and AC output to loads.

Figure 5.1: Typical application wiring diagram.
5.2.1 DC Battery Connection
- Connect the 48V battery bank to the DC input terminals (positive and negative) on the inverter. Use appropriately sized cables and fuses.
- Ensure correct polarity. Reverse polarity can severely damage the unit.
- Connect the included battery temperature sensor to the battery and the designated port on the inverter.
5.2.2 AC-indgangsforbindelse
- Connect the 240V AC input from your utility grid or generator to the AC input terminals.
- Ensure the AC input source is properly fused or circuit-breakered.
5.2.3 AC-udgangsforbindelse
- Connect your 120V/240V split phase loads to the AC output terminals.
- Ensure all output circuits are protected by appropriate circuit breakers.
5.2.4 Jordforbindelse
- Connect the grounding terminal of the inverter to a reliable earth ground.

Figur 5.2: Tilslutninger og betjeningselementer på bagpanelet.
5.3 DIP-switchindstillinger
The inverter features DIP switches to configure various operational parameters, including:
- Batteritype: Select the appropriate battery chemistry (AGM, Gel, Lead Acid, LiFePO4, etc.) for optimized charging.
- Ladestrøm: Adjust the AC battery charger current from 0-100%.
- Utility/Battery Priority: Set whether the inverter prioritizes AC utility power or battery power.
- Lav voltage Afskæring: Konfigurer DC voltage level at which the inverter will shut down to protect batteries from over-discharge.
Refer to the detailed instructions in the full user manual for specific DIP switch configurations.
6. Betjening
6.1 Tænd/sluk
- Sørg for, at alle forbindelser er sikre, før du tænder.
- Turn on the DC breaker from the battery bank first.
- Then, turn on the AC input breaker (if connecting to utility/generator).
- Finally, switch the inverter's main power switch to the "ON" position.
- To power off, reverse the sequence: Inverter OFF, AC input OFF, DC input OFF.
6.2 Fjernbetjening
The included remote control allows for convenient monitoring of system status and basic control functions from a distance. Connect the remote control to the RJ11 port on the inverter using the provided cable.

Figure 6.1: Inverter display panel showing operational data.
6.3 Automatic Generator Start (AGS)
If configured, the AGS feature will automatically start a connected generator when the battery voltage drops below a preset level, ensuring continuous power supply and battery charging.
7. Vedligeholdelse
Regular maintenance helps ensure the longevity and reliable operation of your inverter charger.
- Rensning: Periodically clean the exterior of the inverter with a dry cloth. Ensure vents are free from dust and debris. Do not use liquid cleaners.
- Tilslutningstjek: Annually inspect all electrical connections (DC and AC) for tightness and corrosion. Loose connections can cause overheating and poor performance.
- Batteriinspektion: Regularly check your battery bank for proper voltage, electrolyte levels (for flooded batteries), and terminal cleanliness.
- Ventilation: Ensure the installation area remains well-ventilated and free from obstructions.
8. Fejlfinding
This section provides general guidance for common issues. For detailed troubleshooting steps and error codes, refer to the comprehensive user manual.
8.1 Almindelige problemer og løsninger
- Ingen strømudgang: Check DC battery connections, battery voltage, AC input connection, and inverter's power switch. Verify circuit breakers are not tripped.
- Overbelastningsalarm: Reduce the connected load. The inverter will typically attempt to restart after an overload. If the issue persists, check for short circuits in the load wiring.
- Over Temperature Alarm: Ensure adequate ventilation around the inverter. Clear any obstructions from cooling vents. Reduce ambient temperature if possible.
- Lavt batteri Voltage Alarm: Check battery charge level. Ensure the AC charger is functioning or solar input is sufficient. Adjust low voltage cut-off settings if necessary (refer to DIP switch settings).
- Inverter Not Charging Batteries: Verify AC input is present and stable. Check AC input breaker. Ensure battery type and charge current settings are correct via DIP switches.
If you encounter persistent issues or error codes not covered here, contact SUNGOLDPOWER technical support.
9. Garanti og support
SUNGOLDPOWER provides a 12 måneders garanti for this inverter charger, covering defects in materials and workmanship under normal use.
Derudover lifetime technical service is provided by SUNGOLDPOWER to assist with any operational or technical inquiries you may have.
For warranty claims or technical assistance, please contact SUNGOLDPOWER customer service with your product model number and purchase details.
For more information, visit the official SUNGOLDPOWER website or refer to the contact information provided in your purchase documentation.