SUNGOLDPOWER I12000S4812024060HCCAMSG2

SUNGOLDPOWER 12000W 48V Split Phase Pure Sinus Wave Inverter Oplader Brugermanual

Model: I12000S4812024060HCCAMSG2

1. Introduktion

This manual provides essential information for the safe and efficient operation of your SUNGOLDPOWER 12000W 48V Split Phase Pure Sine Wave Inverter Charger. Please read this manual thoroughly before installation and use to ensure proper function and to prevent damage to the unit or connected equipment.

1.1 Sikkerhedsoplysninger

WARNING: This device operates with high voltages and currents. Improper installation or use can result in serious injury, death, or equipment damage. All electrical work should be performed by qualified personnel in accordance with local electrical codes.

  • Sørg for, at inverteren er installeret i et godt ventileret område, væk fra brandfarlige materialer.
  • Do not expose the inverter to water or excessive moisture.
  • Always disconnect all power sources (AC and DC) before performing any maintenance or wiring.
  • Sørg for korrekt jording af inverteren.
  • Do not attempt to disassemble or repair the inverter yourself. Refer to qualified service personnel.

2. Produktet er slutview og funktioner

The SUNGOLDPOWER 12000W 48V Inverter Charger is a robust, low-frequency pure sine wave inverter designed for off-grid power systems. It integrates an inverter, an AC battery charger, and an automatic transfer switch into a single unit.

SUNGOLDPOWER 12000W 48V Inverter Charger front view

Figur 2.1: Forside view of the SUNGOLDPOWER 12000W 48V Inverter Charger, showing the display panel.

2.1 Nøglefunktioner

  • Strømudgang: 12,000 Watts continuous, 36,000 Watts peak for 20 seconds.
  • Input/output: DC 48V input, AC 240V input, AC 120/240V split phase pure sine wave output.
  • Integreret oplader: 80 Amp AC battery charger with multi-stage opladning.
  • Overførselskontakt: Automatic transfer switch for seamless switching between AC sources (utility/generator) and battery power.
  • Batterikompatibilitet: Supports AGM, Gel, Lead Acid, Lithium-ion, and LiFePO4 batteries.
  • Justerbare indstillinger: User-adjustable charge current (0-100%) and DIP switch settings for utility/battery priority and low voltage afskæring.
  • Automatic Generator Start (AGS): Feature for automatic generator activation.
  • Beskyttelsesfunktioner: Over/lav voltage protection, over temperature protection, and overload protection.
  • Fjernovervågning: Includes a remote control with a 32-foot cable for convenient monitoring and control.
  • Temperatursensor: Battery temperature sensor with a 32-foot cable to protect batteries from overheating during charging.
  • Ansøgninger: Suitable for various applications including homes, cabins, offices, RVs, trailers, and boats.
Diagram highlighting key features of the SUNGOLDPOWER 12KW 48V Pure Sine Inverter

Figure 2.2: Visual representation of the inverter's key features, including 12KW split phase output, battery temperature sensor, remote control, auto generator start, low frequency industrial grade design, and broad compatibility with appliances and batteries.

3. Pakkens indhold

Ved udpakning skal du kontrollere, at alle nedenstående varer er til stede og ubeskadigede:

  • SUNGOLDPOWER 12000W 48V Split Phase Inverter Charger (1 unit)
  • Remote Control with 32-foot cable (1 set)
  • Battery Temperature Sensor with 32-foot cable (1 set)
  • Brugervejledning (dette dokument)
Image showing the SUNGOLDPOWER inverter and its included accessories: user manual, remote control, battery temperature sensor cable, and protective covers for terminals.

Figure 3.1: Included accessories with the SUNGOLDPOWER Inverter Charger.

4. Specifikationer

SpecifikationVærdi
ModelnummerI12000S4812024060HCCAMSG2
Kontinuerlig kraft12000 watt
Peak Power (20s)36000 watt
DC Input Voltage48V
AC -indgang Voltage240V
AC Output Voltage120V/240V Split Phase
Output bølgeformRen Sine Wave
AC Battery Charger Current80 Amps
Produktdimensioner27.6 x 16.5 x 7.9 tommer
Varens vægt197.1 pund
FabrikantSUNGOLDPOWER
Anbefalede anvendelserHome, Office, RV, Trailer, Boat, Workshop
StrømkildeBatteridrevet

5. Installation og opsætning

Proper installation is critical for the safety and performance of your inverter charger. Consult a qualified electrician if you are unsure about any steps.

5.1 Monteringssted

  • Mount the inverter on a sturdy, non-flammable surface.
  • Ensure adequate ventilation around the unit to prevent overheating. Maintain clear space around all vents.
  • Avoid locations exposed to direct sunlight, high temperatures, dust, or moisture.

5.2 Ledningsforbindelser

Refer to the wiring diagram below for proper connection of solar panels (if applicable), MPPT solar controller, battery bank, AC input (utility or generator), and AC output to loads.

Application wiring diagram for the SUNGOLDPOWER inverter charger, showing connections for solar panels, MPPT controller, 48V battery bank, AC input from utility or generator, and AC output to home appliances.

Figure 5.1: Typical application wiring diagram.

5.2.1 DC Battery Connection

  • Connect the 48V battery bank to the DC input terminals (positive and negative) on the inverter. Use appropriately sized cables and fuses.
  • Ensure correct polarity. Reverse polarity can severely damage the unit.
  • Connect the included battery temperature sensor to the battery and the designated port on the inverter.

5.2.2 AC-indgangsforbindelse

  • Connect the 240V AC input from your utility grid or generator to the AC input terminals.
  • Ensure the AC input source is properly fused or circuit-breakered.

5.2.3 AC-udgangsforbindelse

  • Connect your 120V/240V split phase loads to the AC output terminals.
  • Ensure all output circuits are protected by appropriate circuit breakers.

5.2.4 Jordforbindelse

  • Connect the grounding terminal of the inverter to a reliable earth ground.
Bag view of the SUNGOLDPOWER inverter charger showing connection terminals and controls, including DC terminals, AC input/output, circuit breakers, DIP switches, and remote port.

Figur 5.2: Tilslutninger og betjeningselementer på bagpanelet.

5.3 DIP-switchindstillinger

The inverter features DIP switches to configure various operational parameters, including:

  • Batteritype: Select the appropriate battery chemistry (AGM, Gel, Lead Acid, LiFePO4, etc.) for optimized charging.
  • Ladestrøm: Adjust the AC battery charger current from 0-100%.
  • Utility/Battery Priority: Set whether the inverter prioritizes AC utility power or battery power.
  • Lav voltage Afskæring: Konfigurer DC voltage level at which the inverter will shut down to protect batteries from over-discharge.

Refer to the detailed instructions in the full user manual for specific DIP switch configurations.

6. Betjening

6.1 Tænd/sluk

  • Sørg for, at alle forbindelser er sikre, før du tænder.
  • Turn on the DC breaker from the battery bank first.
  • Then, turn on the AC input breaker (if connecting to utility/generator).
  • Finally, switch the inverter's main power switch to the "ON" position.
  • To power off, reverse the sequence: Inverter OFF, AC input OFF, DC input OFF.

6.2 Fjernbetjening

The included remote control allows for convenient monitoring of system status and basic control functions from a distance. Connect the remote control to the RJ11 port on the inverter using the provided cable.

Close-up of the SUNGOLDPOWER inverter's display panel, showing battery voltage, belastningsprocenttage, and operational status indicators.

Figure 6.1: Inverter display panel showing operational data.

6.3 Automatic Generator Start (AGS)

If configured, the AGS feature will automatically start a connected generator when the battery voltage drops below a preset level, ensuring continuous power supply and battery charging.

7. Vedligeholdelse

Regular maintenance helps ensure the longevity and reliable operation of your inverter charger.

  • Rensning: Periodically clean the exterior of the inverter with a dry cloth. Ensure vents are free from dust and debris. Do not use liquid cleaners.
  • Tilslutningstjek: Annually inspect all electrical connections (DC and AC) for tightness and corrosion. Loose connections can cause overheating and poor performance.
  • Batteriinspektion: Regularly check your battery bank for proper voltage, electrolyte levels (for flooded batteries), and terminal cleanliness.
  • Ventilation: Ensure the installation area remains well-ventilated and free from obstructions.

8. Fejlfinding

This section provides general guidance for common issues. For detailed troubleshooting steps and error codes, refer to the comprehensive user manual.

8.1 Almindelige problemer og løsninger

  • Ingen strømudgang: Check DC battery connections, battery voltage, AC input connection, and inverter's power switch. Verify circuit breakers are not tripped.
  • Overbelastningsalarm: Reduce the connected load. The inverter will typically attempt to restart after an overload. If the issue persists, check for short circuits in the load wiring.
  • Over Temperature Alarm: Ensure adequate ventilation around the inverter. Clear any obstructions from cooling vents. Reduce ambient temperature if possible.
  • Lavt batteri Voltage Alarm: Check battery charge level. Ensure the AC charger is functioning or solar input is sufficient. Adjust low voltage cut-off settings if necessary (refer to DIP switch settings).
  • Inverter Not Charging Batteries: Verify AC input is present and stable. Check AC input breaker. Ensure battery type and charge current settings are correct via DIP switches.

If you encounter persistent issues or error codes not covered here, contact SUNGOLDPOWER technical support.

9. Garanti og support

SUNGOLDPOWER provides a 12 måneders garanti for this inverter charger, covering defects in materials and workmanship under normal use.

Derudover lifetime technical service is provided by SUNGOLDPOWER to assist with any operational or technical inquiries you may have.

For warranty claims or technical assistance, please contact SUNGOLDPOWER customer service with your product model number and purchase details.

For more information, visit the official SUNGOLDPOWER website or refer to the contact information provided in your purchase documentation.

Relaterede dokumenter - I12000S4812024060HCCAMSG2

Preview Brugermanual til SunGoldPower SPH-seriens alt-i-en solcelleladningsinverter
Omfattende brugermanual til SunGoldPower SPH-seriens alt-i-en solcelle-ladeinvertere, der dækker installation, drift, vedligeholdelse og tekniske specifikationer for modellerne SPH8K48SP og SPH10K48SP.
Preview Fejlfindingsvejledning til Sungoldpower Pure Sine Wave-inverteroplader
En omfattende fejlfindingsvejledning til Sungoldpower Pure Sine Wave-inverteropladere, der dækker almindelige problemer såsom unormale AC-aflæsninger, problemer med batteriopladning, udgangsfejl og ventilatordrift.
Preview Brugermanual til LFP-serien af ​​ren sinusbølge-inverter/oplader
Brugermanual til LFP-serien af ​​ren sinusbølgeinverter/oplader, med detaljerede sikkerhedsoplysninger, introduktion, installation, elektrisk ydeevne, fejlfinding og specifikationer.
Preview SunGoldPower SPH302480A Alt-i-en solcelleladningsinverter brugermanual
Denne brugermanual indeholder omfattende instruktioner til SunGoldPower SPH302480A alt-i-en hybrid solcelle-opladningsinverteren, der dækker sikkerhed, installation, driftstilstande, LCD-skærmfunktioner, andre funktioner, beskyttelsesmekanismer, systemvedligeholdelse og detaljerede tekniske parametre.
Preview Sungoldpower SPH8K48SP / SPH10K48SP Alt-i-en solcelleladningsinverter brugermanual
Omfattende brugermanual til Sungoldpower SPH8K48SP og SPH10K48SP alt-i-en solcelle-ladeinverterne, der dækker sikkerhed, installation, drift, kommunikation, fejlfinding og tekniske specifikationer.
Preview Brugermanual til SunGoldPower energilagringssystem
Brugermanual til SunGoldPower energilagringssystem (ESS), der dækker installation, tilslutning, drift, vedligeholdelse og tekniske specifikationer for modellerne SGN7.6K1HB-48 og SGN11.4KHB-48.