Onyx 3200

Onyx Re-Arm Kit for 3200 Automatic/Manual Inflatable PFD Instruction Manual

1. Introduktion

This instruction manual provides essential information for the proper use, installation, and maintenance of the Onyx Re-Arm Kit, model 3200. This kit is designed specifically for Onyx automatic/manual inflatable personal flotation devices (PFDs) that require a 24-gram CO2 cylinder. Adhering to these instructions ensures the continued safety and functionality of your inflatable PFD.

2. Produktet er slutview og komponenter

The Onyx Re-Arm Kit 3200 contains the necessary components to restore your inflatable PFD to an operational state after it has been deployed or if components require replacement due to expiration or damage.

Sættets indhold:

Onyx Re-Arm Kit components: a gold-colored CO2 cylinder, a yellow bobbin, and a green indicator clip.

This image displays the three primary components of the Onyx Re-Arm Kit: a 24-gram CO2 cylinder with a threaded neck, a yellow water-soluble bobbin, and a green indicator clip. These parts are crucial for the proper function of an automatic/manual inflatable PFD.

3. Setup and Installation (Re-Arming Instructions)

Before re-arming, ensure your PFD is completely deflated and dry. Always refer to your specific Onyx PFD's instruction manual for detailed re-arming procedures, as steps may vary slightly by model. The following are general guidelines.

General Re-Arming Steps:

  1. Remove Used Components: If the PFD has been deployed, carefully remove the spent CO2 cylinder by unscrewing it. Discard the old cylinder. Remove any old bobbin or indicator clips.
  2. Inspect PFD: Thoroughly inspect the PFD for any damage, tears, or punctures. Ensure the inflation bladder is intact and the oral inflation tube cap is secure.
  3. Install New Bobbin (for Automatic PFDs): Locate the automatic inflation mechanism. Insert the new yellow water-soluble bobbin into the designated slot. Ensure it is seated correctly according to your PFD's manual. This bobbin dissolves in water, triggering automatic inflation.
  4. Install New CO2 Cylinder: Carefully screw the new 24-gram CO2 cylinder into the inflation mechanism. Turn clockwise until it is hand-tight. Spænd ikke for meget. Ensure the cylinder is fully seated.
  5. Install Green Indicator Clip: Attach the green indicator clip to the inflation mechanism. This clip typically confirms that the PFD is armed and ready for use. Refer to your PFD manual for the exact placement.
  6. Repack PFD: Once re-armed, carefully fold and repack the PFD according to its original instructions. Ensure the pull-cord for manual inflation is accessible and not obstructed.

Vigtig: Always ensure the CO2 cylinder is new and undamaged. Never use a cylinder that has been punctured or shows signs of corrosion.

4. Operating the Re-Armed PFD

After re-arming, your Onyx PFD is ready for use. It offers both automatic and manual inflation capabilities.

Always ensure the PFD is worn correctly and securely before engaging in water activities.

5. Vedligeholdelse og inspektion

Regular inspection and proper maintenance are crucial for the reliability of your inflatable PFD and its re-arm kit components.

Replace the re-arm kit components immediately after each inflation or if any component is damaged or expired.

6. Fejlfinding

This section addresses common issues related to the re-arm kit and PFD inflation.

ProblemMulig årsagLøsning
PFD does not inflate automatically.Bobbin is expired or incorrectly installed. Not enough water exposure.Check bobbin expiration date and installation. Ensure full submersion. Manually inflate if necessary.
PFD does not inflate manually.CO2 cylinder is not properly seated, is empty, or expired. Pull cord not activated.Ensure cylinder is hand-tight. Check green indicator. Replace cylinder if empty/expired. Pull cord firmly.
PFD inflates accidentally.Bobbin exposed to moisture. Manual pull cord snagged.Keep PFD dry when not in use. Ensure pull cord is not exposed or snagged during wear or storage.
PFD loses air after inflation.Puncture in bladder. Loose oral inflation cap.Perform leak test. Inspect bladder for damage. Tighten oral inflation cap. If damaged, PFD may need professional repair or replacement.

7. Specifikationer

8. Garanti og support

For specific warranty information regarding your Onyx Re-Arm Kit or PFD, please refer to the documentation included with your original PFD purchase or visit the official Onyx Outdoor website. For technical support or inquiries, please contact Onyx Outdoor customer service directly.

Note: Using non-Onyx approved re-arm kits or components may void your PFD's warranty and compromise its safety performance.

Relaterede dokumenter - 3200

Preview Onyx RCR GT 41Ah Battery Quick Start Guide
Get your Onyx RCR GT 41Ah battery up and running quickly with this essential quick start guide. Learn how to install, connect via Bluetooth, and use the Onyx BMS App for optimal performance.
Preview Onyx Healthcare 2024 Katalog: Fremme af innovation inden for medicinsk AI
Udforsk Onyx Healthcare 2024-kataloget, der byder på banebrydende medicinsk AI-hardware, herunder AI-klare pc'er, medicinske vogncomputere, tablets og skærme designet til forbedret patientpleje og driftseffektivitet. Opdag løsninger til digitale operationsstuer og avanceret medicinsk billeddannelse.
Preview Onyx Fireplace Remote Control: Functions and Operation Guide
Detailed guide to operating the Onyx fireplace remote control, explaining button functions, flame settings, heating controls, and timer features for Regency fireplaces.
Preview BOOX Note3 Uživatelský manuál - Návod k použití
Komplet vejledning til BOOX Note3 fra Onyx International. Oplysninger om funkcích, příslušenství, bezpečnostních pokynech and specificcích.
Preview ONYX DX15 Battery Autoscrubber Operator Manual
Comprehensive operator manual for the ONYX DX15 Battery Autoscrubber, covering operation, maintenance, safety, troubleshooting, and technical specifications. Includes detailed instructions for safe and effective use.
Preview Monteringsvejledning til Onyx Milazzo-møbler
Omfattende installationsvejledning til Onyx Milazzo-møblerne, designet til brug med Avanti 110RW-pejsen. Indeholder sikkerhedsadvarsler, styklister og trinvise monteringsvejledninger.