1. Produktet er slutview
The APC Back-UPS Pro 1500VA (BR1500G) is an Uninterruptible Power Supply (UPS) designed to provide guaranteed battery backup and surge protection for high-performance computer systems, networks, external storage devices, game consoles, and other sensitive electronics. It ensures continuous power during outages and protects against harmful power fluctuations.

Image 1.1: The APC Back-UPS Pro 1500VA (BR1500G) unit (left) and the optional BR24BPG External Battery Pack (right). The UPS provides power backup and surge protection, while the external battery pack extends runtime.
Nøglefunktioner:
- Guaranteed Battery Backup: Provides power during outages, allowing for safe shutdown or continued operation.
- Overspændingsbeskyttelse: Safeguards connected equipment from damaging power surges and spikes.
- Automatisk voltage Forordning (AVR): Corrects minor power fluctuations without switching to battery, preserving battery life.
- LCD-skærm: Provides real-time status updates on power conditions and UPS parameters.
- Energy Saving Functionality: Helps reduce energy consumption.
- PowerChute Management Software: Enables safe system shutdown and advanced power management.
- APFC Compatibility: Ensures electronics with Active Power Factor Correction (PFC) operate correctly.
- 10 stikkontakter: Includes 5 battery backup and surge protected outlets, and 5 surge-only outlets.
- External Battery Pack Support: Compatible with BR24BPG for extended runtime.
2. Opsætning og installation
2.1 Udpakning og første inspektion
Carefully unpack the UPS and its components. Inspect for any shipping damage. If damage is found, notify the carrier and dealer. The package should contain the UPS unit, a USB cable, and documentation.
2.2 Placering
Place the UPS on a flat, stable surface away from direct sunlight, excessive heat, or moisture. Ensure adequate ventilation around the unit. Do not block the ventilation openings.
2.3 Batteritilslutning
The UPS battery may be disconnected for shipping. Refer to the quick start guide for specific instructions on connecting the internal battery. For the BR1500G, the battery is typically pre-installed but may require a simple connection step. Ensure the battery is securely connected before proceeding.
2.4 Tilslutning af udstyr
The BR1500G features 10 outlets. It is crucial to connect your devices to the correct outlets:
- Battery Backup & Surge Protected Outlets (5 outlets): Tilslut kritisk udstyr såsom din computer, skærm, eksterne harddiske og netværksrouter til disse stikkontakter. Disse enheder modtager strøm fra batteriet under en strømafbrydelse.tage.
- Surge Only Outlets (5 outlets): Connect non-critical equipment like printers, scanners, or speakers to these outlets. These devices are protected from surges but will not receive battery power during an outage.

Billede 2.1: Bagside view of the APC Back-UPS Pro, illustrating the different types of outlets for battery backup and surge protection.
2.5 Tilslutning til strømforsyning
Plug the UPS power cord directly into a grounded 3-prong wall outlet. Avoid using extension cords or surge protectors with the UPS. Allow the UPS to charge for at least 24 hours before initial use to ensure full battery capacity.
2.6 PowerChute Software Installation
For advanced power management, automatic graceful shutdown, and energy monitoring, install the PowerChute Personal Edition software. Connect the UPS to your computer using the provided USB cable. Download the latest software version from the official APC webwebsted.

Image 2.2: PowerChute Software provides additional power protection and management features, including energy reporting and graceful shutdown.
3. Betjeningsvejledning
3.1 Tænd/sluk for UPS'en
- At tænde: Press and hold the POWER button on the front panel until a short beep is heard. The LCD display will illuminate.
- At slukke: Press and hold the POWER button until a long beep is heard and the display turns off.
3.2 Forståelse af LCD-skærmen
The LCD display provides critical information about the UPS status. Use the DISPLAY button to cycle through various parameters such as input voltage, output voltage, battery charge level, estimated runtime, load percentage, and event history.

Image 3.1: The LCD display on the APC Back-UPS Pro provides real-time information, including status of Automatic Voltage Regulation (AVR) and sine wave output.
3.3 Automatisk Voltage Forordning (AVR)
UPS'en korrigerer automatisk mindre volumentage fluctuations (sags and swells) without using battery power. This feature extends battery life by reducing the number of times the UPS switches to battery mode.
3.4 Power Outage Betjening
Under en magt outage, the UPS will automatically switch to battery power, providing continuous power to connected critical devices. The UPS will emit an audible alarm (beeping) to indicate it is operating on battery. The LCD display will show the estimated runtime remaining.
If PowerChute software is installed and configured, it can initiate a graceful shutdown of your computer system before the battery is depleted, preventing data loss.

Image 3.2: PowerChute Serial Shutdown enables graceful system shutdown during extended power outages, protecting your data.
4. Vedligeholdelse
4.1 Batteripleje og udskiftning
The UPS contains a user-replaceable, sealed lead-acid battery. The battery typically lasts 3-5 years depending on usage and environmental conditions. The UPS will indicate when the battery needs replacement, usually via an alarm and a message on the LCD display.

Image 4.1: The APC Back-UPS Pro features a replaceable battery, contributing to its longevity and Energy-Star certification.
When replacing the battery, use only APC-approved replacement battery cartridges (RBCs) to ensure compatibility and optimal performance. Refer to the APC website or contact support for the correct RBC model for your BR1500G.
4.2 Rengøring
Clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris to maintain proper airflow.
4.3 External Battery Pack (BR24BPG)
If you are using the optional BR24BPG External Battery Pack, ensure its connection cable is securely attached to the UPS. The external battery pack also contains user-replaceable batteries and should be maintained similarly to the UPS's internal battery.
5. Fejlfinding
This section provides solutions to common issues you might encounter with your APC Back-UPS Pro 1500VA. For more complex problems, refer to the full user manual available on the APC webwebstedet eller kontakt teknisk support.
5.1 UPS Does Not Turn On or No Power Output
- Tjek strømtilslutning: Ensure the UPS power cord is securely plugged into a live, grounded wall outlet.
- Batteriforbindelse: Verify the internal battery is properly connected.
- Oplad batteri: Allow the UPS to charge for at least 24 hours. A completely discharged battery may take time to respond.
- Overbelaste: Disconnect some devices from the battery backup outlets. The UPS may be overloaded.
- Afbryder: Check if the circuit breaker on the back of the UPS has tripped. Press it in to reset.
5.2 UPS Beeps Continuously or Frequently
- På batteri: If the utility power is out, the UPS will beep to indicate it's running on battery. This is normal.
- Lavt batteri: A rapid beeping indicates a low battery. Save your work and shut down your computer.
- Overbelaste: A continuous tone often indicates an overload. Reduce the load on the battery backup outlets.
- Udskiftning af batteri: A specific alarm pattern may indicate the battery needs replacement. Check the LCD display for messages.
5.3 UPS Does Not Provide Expected Runtime
- Batteriets alder: Batteries degrade over time. If the battery is older than 3-5 years, it may need replacement.
- Indlæs: Ensure only critical devices are connected to battery backup outlets. High load reduces runtime.
- Batteri ikke fuldt opladet: Ensure the UPS has been plugged in and charging for at least 24 hours.
- Batteritest: Perform a battery self-test (if available via PowerChute or front panel) to assess battery health.
6. Tekniske specifikationer
| Specifikation | Værdi |
|---|---|
| Modelnummer | BR1500G |
| Mærke | APC |
| Kapacitet | 1500VA / 865W |
| Input bindtage | 120V AC (Nominal) |
| Udgang Voltage | 120V AC (Nominal) |
| Output bølgeform | Sine wave (on battery) |
| Outlets | 10 total (5 Battery Backup & Surge, 5 Surge Only) |
| Batteritype | Sealed Lead Acid, Maintenance Free |
| Typisk genopladningstid | 8 timer til 90 % |
| Varens vægt | 26.6 pund (12.07 kg) |
| Farve | Sort |
| Første ledige dato | 4. februar 2017 |
7. Garanti og support
7.1 Produktgaranti
The APC Back-UPS Pro 1500VA (BR1500G) comes with a 3 års garanti. Denne garanti dækker fejl i materialer og udførelse ved normal brug.
7.2 Equipment Protection Policy
APC offers a lifetime $150,000 Equipment Protection Policy. This policy provides coverage for equipment properly connected to the UPS that is damaged by a power surge or lightning strike while the UPS is functioning correctly. Refer to the official APC website for full terms and conditions of this policy.
7.3 Teknisk support
For technical assistance, troubleshooting, or warranty claims, please contact APC Customer Support. Visit the official APC webwebsted (www.apc.com/us/en/support/) for contact information, FAQs, and additional resources.