Indledning
This instruction manual provides detailed guidance for the installation, operation, maintenance, and troubleshooting of your Phylrich Pressure Balanced Shower Rough Valve, Model DFPHY. Please read this manual thoroughly before beginning installation or use to ensure proper function and safety.
The Phylrich DFPHY is a high-quality rough valve designed to provide consistent water temperature and pressure for your shower system. Its pressure-balanced design helps prevent sudden temperature changes when other water sources in the home are used.
Sikkerhedsoplysninger
ADVARSEL:
- Sluk altid for hovedvandforsyningen, inden du forsøger at installere eller vedligeholde produktet.
- Hvis du er usikker på nogen del af installationsprocessen, skal du kontakte en kvalificeret VVS-installatør.
- Brug passende personlige værnemidler (PPE) såsom sikkerhedsbriller og handsker under installationen.
- Sørg for, at alle forbindelser er sikre og lækagefri for at forhindre vandskader.
- This product is designed for specific plumbing applications. Do not modify the valve or use it for purposes other than its intended design.
Opsætning og installation
Tjekliste før installation
- Verify that all necessary components are present and undamaged.
- Ensure that the rough-in dimensions in your wall cavity are compatible with the valve.
- Confirm that your water supply lines are ready for connection.
Værktøj påkrævet
- Justerbar skruenøgle
- Rørskærer eller hacksav
- Målebånd
- Niveau
- Solder and flux (for copper connections) or appropriate sealant (for threaded connections)
- Skruetrækker (Phillips/Fladhoved)
Installationstrin
- Sluk for vandforsyningen: Locate the main water shut-off valve for your home and turn it off. Open nearby faucets to drain residual water from the lines.
- Prepare Rough-in Opening: Ensure the wall opening is appropriately sized for the valve body. The valve should be securely mounted to a stud or blocking within the wall.
- Tilslut vandledninger: Identify the hot and cold water inlets on the valve. Connect the hot water supply to the port marked 'H' and the cold water supply to the port marked 'C'. Connect the shower outlet to the top port and the tub spout outlet (if applicable) to the bottom port. Use appropriate plumbing techniques (soldering, threading with sealant) to ensure watertight connections.
- Fastgør ventilen: Mount the valve securely to the framing using appropriate fasteners. Ensure the valve is level and plumb.
- Test for lækager: Once all connections are made, slowly turn on the main water supply. Inspect all connections for leaks. If leaks are detected, turn off the water, tighten connections, and retest.
- Installer trimsæt: After successful leak testing and wall finishing, install the decorative trim kit (handle, escutcheon, etc.) according to the trim kit's specific instructions.

Image: The Phylrich Pressure Balanced Shower Rough Valve (Model DFPHY) showing its brass construction and connection points for hot, cold, and outlet lines. This image illustrates the core component before the decorative trim is installed.
Betjeningsvejledning
The Phylrich Pressure Balanced Shower Rough Valve operates in conjunction with its corresponding trim kit. The rough valve itself controls the mixing of hot and cold water to maintain a consistent temperature, even with fluctuations in water pressure from other household fixtures.
- Temperaturkontrol: Rotate the handle (part of the trim kit) to adjust the water temperature. Typically, rotating counter-clockwise increases hot water, and clockwise increases cold water.
- Lydstyrkekontrol: If your trim kit includes a separate volume control, rotate or pull the handle to adjust the water flow rate.
- Omleder (hvis relevant): If your system includes a tub spout, use the diverter on the trim kit to switch water flow between the showerhead and the tub spout.
The pressure-balancing mechanism within the valve automatically adjusts to maintain your selected temperature, providing a comfortable and safe showering experience.
Opretholdelse
Regular maintenance ensures the longevity and optimal performance of your Phylrich Pressure Balanced Shower Rough Valve.
- Rensning: Clean the visible parts of the trim kit regularly with a soft cloth and mild, non-abrasive cleaner. Avoid harsh chemicals or abrasive pads, as they can damage the finish.
- Inspektion af patron: If you notice a decrease in water flow, inconsistent temperature, or persistent dripping, the internal cartridge may need inspection or replacement. This typically requires turning off the water supply and removing the trim kit. Consult a professional plumber if you are unsure.
- Lækagekontrol: Periodically check for any signs of leaks around the valve body or connections, especially during routine plumbing inspections.
Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Uregelmæssig vandtemperatur | Faulty pressure balancing cartridge; debris in cartridge; inadequate hot/cold water supply. | Inspect/replace cartridge; flush lines; check water heater settings and supply pressure. |
| Lav vandgennemstrømning | Clogged showerhead/tub spout; debris in valve cartridge; partially closed shut-off valve. | Clean showerhead/spout; inspect/clean cartridge; ensure all shut-off valves are fully open. |
| Water dripping from showerhead/spout | Worn or damaged cartridge seals. | Udskift ventilpatronen. |
| Ingen vandgennemstrømning | Main water supply off; valve completely clogged; severe plumbing issue. | Check main water supply; inspect valve for blockages; consult a plumber. |
If troubleshooting steps do not resolve the issue, it is recommended to contact a qualified plumber or Phylrich customer support.
Specifikationer
| Feature | Detalje |
|---|---|
| Mærke | Phylrich |
| Modelnummer | DFPHY |
| Ventil type | Pressure Balanced Rough Valve |
| Materiale | Messing |
| Udvendig finish | Nickel, Brass (referring to the valve body itself, not trim) |
| Antal havne | 2 (inlet/outlet configuration) |
| Specifikation Met | CAL Green, Low Lead Compliant |
| Fabrikant | Phylrich |
| Første ledige dato | 28. april 2015 |
Garanti og support
For specific warranty information regarding your Phylrich Pressure Balanced Shower Rough Valve, please refer to the warranty documentation included with your purchase or visit the official Phylrich webGarantibetingelserne dækker typisk fabrikationsfejl i en bestemt periode.
For technical support, replacement parts, or further assistance, please contact Phylrich customer service. Contact information can usually be found on the manufacturer's webwebstedet eller på produktemballagen.
Det anbefales at gemme din købsbevis til garantikrav.