UHPPOTE HBK-A02

UHPPOTE HBK-A02 125KHz RFID Standalone Door Access Control Keypad User Manual

Model: HBK-A02

1. Introduktion

This manual provides detailed instructions for the installation, programming, operation, and maintenance of the UHPPOTE HBK-A02 125KHz RFID Standalone Door Access Control Keypad. This device is designed to provide secure access control for various applications, supporting up to 1000 card users.

Front view of the UHPPOTE HBK-A02 access control keypad with illuminated buttons and a red indicator light.

Figure 1: UHPPOTE HBK-A02 Keypad Front View

2. Nøglefunktioner

  • High quality and high security, sensitively and response quickly.
  • Full programming from the keypad, support add/delete cards, set password, etc.
  • Door bell button support external doorbell.
  • Uses high-performance MCU for stable performance and low-power circuit for extended service life.
  • Functions as a standalone keypad, no computer connection required.
  • Suitable for factories, houses, residential quarters, offices, and mechanical/electrical control equipment.

3. Specifikationer

FeatureDetalje
ModelnummerHBK-A02
FabrikantUHPPOTE
Input bindtage12 volt DC
Produktdimensioner4.72 x 3.07 x 0.87 tommer
Varens vægt3.21 ounces (91 gram)
RFID-frekvens125KHz
BrugerkapacitetUp to 1000 Card Users
FarveSort
UPC701385688196

4. Installation

Proper installation is crucial for the optimal performance and security of your access control keypad. Ensure all power is disconnected before beginning installation.

4.1 Montering af tastaturet

  1. Choose a suitable mounting location near the door, ensuring it is protected from direct weather exposure if installed outdoors.
  2. Use the provided mounting screws to secure the back plate of the keypad to the wall.
  3. Route the necessary wiring through the wall or conduit to the keypad's connection point.
  4. Attach the keypad front panel to the back plate after wiring is complete.
UHPPOTE HBK-A02 access control keypad mounted on a brick wall next to a white door, with a hand holding a blue RFID card near the keypad for access.

Figure 2: Keypad Mounted on a Door Frame

4.2 Ledningsforbindelser

The HBK-A02 keypad requires a 12V DC power supply. Carefully follow the wiring diagrams below. Incorrect wiring can damage the device or connected components.

Bag view of the UHPPOTE HBK-A02 access control keypad, showing the wiring harness with multiple colored wires connected to a white terminal block. Product model and input voltage information are visible on the label.

Figur 3: Bagside View of Keypad with Wiring Harness

Nærbillede bagfra view of the UHPPOTE HBK-A02 access control keypad, highlighting the wiring terminal block and the label with model HBK-A02, input 12VDC, and FCC ID.

Figure 4: Close-up of Wiring Terminal Block

4.2.1 Common Power Supply Diagram

This diagram illustrates connections when using a single power supply for both the keypad and the electric lock.

Wiring diagram for the UHPPOTE HBK-A02 access control keypad using a common power supply, showing connections for power, exit button, fail-secure lock, fail-safe lock, and bell.

Figure 5: Common Power Supply Wiring Diagram

4.2.2 Special Power Supply Diagram

This diagram shows connections when using a dedicated access control power supply unit, which often includes battery backup and advanced control features.

Wiring diagram for the UHPPOTE HBK-A02 access control keypad using a special power supply, detailing connections for power, exit button, fail-secure lock, fail-safe lock, and bell.

Figure 6: Special Power Supply Wiring Diagram

5. Programmering

The keypad is programmed directly using the numeric buttons. The default master code is 123456.

5.1 Gå ind i programmeringstilstand

  1. Trykke *.
  2. Enter the 6-digit Master Code (default: 123456).
  3. Trykke #.
  4. The red LED will flash, indicating programming mode.

5.2 Exiting Programming Mode

Trykke * to exit programming mode at any time.

5.3 Ændring af masterkoden

  1. Gå ind i programmeringstilstand.
  2. Trykke 0.
  3. Enter the new 6-digit Master Code.
  4. Enter the new 6-digit Master Code again to confirm.
  5. Trykke #.
  6. Afslut programmeringstilstand.

5.4 Adding User Cards/Codes

The keypad supports up to 1000 user cards or codes.

  1. Gå ind i programmeringstilstand.
  2. Trykke 1.
  3. For RFID cards: Present the card to the keypad. The keypad will beep to confirm. Repeat for additional cards.
  4. For User Codes: Enter a 4-digit to 6-digit user code, then press #. Enter the code again and press # for at bekræfte.
  5. Afslut programmeringstilstand.

5.5 Deleting User Cards/Codes

  1. Gå ind i programmeringstilstand.
  2. Trykke 2.
  3. For RFID cards: Present the card to the keypad. The keypad will beep to confirm deletion. Repeat for additional cards.
  4. For User Codes: Enter the 4-digit to 6-digit user code to delete, then press #.
  5. Afslut programmeringstilstand.

5.6 Setting Relay Unlock Time

This sets how long the door remains unlocked after a valid access. The default is 5 seconds.

  1. Gå ind i programmeringstilstand.
  2. Trykke 3.
  3. Enter a 2-digit number for the unlock time in seconds (e.g., 05 i 5 sekunder, 00 i 0.2 sekunder).
  4. Trykke #.
  5. Afslut programmeringstilstand.

6. Betjening

6.1 Gaining Access

  • Using an RFID Card: Present a registered RFID card to the keypad. The keypad will beep, and the door will unlock for the set duration.
  • Brug af en brugerkode: Enter your registered user code (4-6 digits) followed by #. The keypad will beep, and the door will unlock for the set duration.

6.2 Dørklokkefunktion

Tryk på Klokke button on the keypad to activate an external doorbell (if connected).

7. Vedligeholdelse

  • Rensning: Wipe the keypad surface with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Miljøbeskyttelse: Ensure the keypad is protected from extreme temperatures, direct sunlight, and moisture to prolong its lifespan.
  • Regelmæssig test: Periodically test the keypad's functionality, including card/code access and the exit button, to ensure proper operation.

8. Fejlfinding

ProblemMulig årsagLøsning
Keypad does not power on.Ingen strømforsyning eller forkert ledningsføring.Check 12V DC power supply connection and wiring according to diagrams.
Door does not unlock with valid card/code.Card/code not registered, incorrect code, or lock wiring issue.Verify card/code registration. Check wiring to the electric lock (NO/NC/COM). Ensure relay unlock time is set correctly.
Keypad beeps continuously or acts erratically.Interference or internal fault.Disconnect power for 30 seconds and reconnect. If problem persists, contact support.
Cannot enter programming mode.Incorrect Master Code or not following sequence.Ensure you are using the correct 6-digit Master Code (default 123456) and the sequence * + Masterkode + #.

9. Sikkerhedsoplysninger

  • Afbryd altid strømmen, før du udfører nogen form for ledningsføring eller vedligeholdelse.
  • Sørg for, at alle ledningsforbindelser er sikre og isolerede for at forhindre kortslutninger.
  • Udsæt ikke enheden for vand eller for høj luftfugtighed.
  • This device is intended for low-voltage applications (12V DC). Do not connect to higher voltage kilder.
  • Installationen bør udføres af kvalificeret personale, hvis du er usikker på den elektriske ledningsføring.

Relaterede dokumenter - HBK-A02

Preview UHPPOTE HBK-A02 Brugervejledning til adgangskontroltastatur
Omfattende brugermanual til UHPPOTE HBK-A02 adgangskontroltastaturet, der beskriver installation, specifikationer, betjening, ledningsføring og fejlfinding. Understøtter RFID-kort og PIN-adgang.
Preview UHPPOTE HBK-A04T 2.4-tommer TFT RFID adgangskontrolterminal brugermanual
Brugermanual til UHPPOTE HBK-A04T 2.4-tommer TFT RFID-adgangskontrolterminal, der beskriver installation, opsætning, brugeradministration, dørindstillinger, enhedskonfiguration og integration med Tuya Smart APP.
Preview UHPPOTE HBK-D01 Wiegand RFID Reader User Manual and Installation Guide
This document provides comprehensive information for the UHPPOTE HBK-D01 Wiegand RFID reader, including its features, technical specifications, wiring instructions, installation guide, and FCC compliance details. Designed for access control systems, it offers reliable performance and durability.
Preview UHPPOTE HBK-A03 Brugervejledning til adgangskontroltastatur
User manual for the UHPPOTE HBK-A03 Access Control Keypad, detailing its features, specifications, installation, wiring, and operation.
Preview UHPPOTE HBK-A01 Brugervejledning til adgangskontroltastatur
Brugermanual til UHPPOTE HBK-A01 adgangskontroltastatur, med detaljer om installation, specifikationer, funktioner, betjening og fejlfinding.
Preview UHPPOTE HBK-D02K Wiegand RFID Reader User Manual
User manual for the UHPPOTE HBK-D02K Wiegand RFID Reader, covering introduction, features, specifications, wiring, installation, and FCC warnings.