1. Introduktion
This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of your Hormann RotaMatic 2 SK BiSecur Swing Gate Operator Kit. Please read this manual thoroughly before beginning any installation or operation procedures. Retain this manual for future reference.
The Hormann RotaMatic 2 SK BiSecur is designed for automating swing gates with specific dimensions and weight limits. Adherence to these guidelines and all safety instructions is crucial for optimal performance and user safety.
2. Sikkerhedsinstruktioner
ADVARSEL: Manglende overholdelse af disse sikkerhedsinstruktioner kan resultere i alvorlig personskade eller materielle skader.
- Installation must be performed by qualified personnel in accordance with all local and national electrical and safety codes.
- Ensure the gate structure is in good working order and properly balanced before installing the operator.
- Disconnect power to the gate operator before performing any maintenance or service.
- Hold børn og kæledyr væk fra portområdet, især under drift.
- Do not operate the gate if any part of the system is damaged or malfunctioning.
- Install all safety devices, such as photocells and warning lights, as specified in the detailed installation manual.
- Never attempt to repair the operator yourself. Contact qualified service personnel.
3. Pakkens indhold
The Hormann RotaMatic 2 SK BiSecur Swing Gate Operator Kit typically includes the following components. Please verify all items are present upon unboxing.

Figur 3.1: Overview of the Hormann RotaMatic 2 SK BiSecur Swing Gate Operator Kit components.
- Two (2) RotaMatic 2 Spindle Units with 24V DC Motors (IP 44 protection)
- One (1) Electronic Control Unit (Microprocessor-controlled, 24V DC, IP 65 protection) with integrated radio receiver
- One (1) Warning Light (e.g., EL301)
- Two (2) BiSecur Hand Transmitters (Remote Controls)
- Mounting Accessories and Fastening Material (brackets, screws, anchors, cable ties)
- Installation Manual (detailed version)
- Garantikort

Figur 3.2: The two RotaMatic 2 spindle drive units.

Figur 3.3: Various accessories including remote controls, warning light, and cables.

Figur 3.4: The electronic control unit and an automatic gate warning sign.

Figur 3.5: Mounting brackets and various fastening hardware.

Figur 3.6: A Hormann BiSecur hand transmitter (remote control).
4. Specifikationer
| Feature | Specifikation |
|---|---|
| Model | RotaMatic 2 SK BiSecur |
| Fabrikant | Hormann |
| Porttype | Swing Gate |
| Maks. portbladbredde | 2500 mm (2.5 meters) |
| Max. Gate Leaf Weight | 220 kg |
| Motortype | 24V DC |
| Spindle Unit Protection Rating | IP 44 |
| Control Unit Protection Rating | IP 65 |
| Kontrolenhedsfunktioner | Microprocessor control, 16 programmable DIL switches, integrated radio receiver |
| Produktmål (L x B x H) | 125 x 19 x 25 cm |
| Varens vægt | 14 kg (30.86 lbs) |
| Montering påkrævet | Ja |
| Producentreference | 4512610 |
| UPC | 783854710348 |
5. Opsætning og installation
Installation of the Hormann RotaMatic 2 SK BiSecur operator requires careful attention to detail and adherence to the comprehensive installation manual provided with the kit. The following is a general overview and not a substitute for the detailed instructions.
5.1 Kontrol før installation
- Verify the gate operates smoothly and freely by hand.
- Ensure the gate hinges are robust and in good condition.
- Confirm the gate dimensions and weight are within the operator's specifications (max. 2500mm width, max. 220kg weight per leaf).
- Plan the cable routing for power and control wires, ensuring they are protected from damage and moisture.
5.2 Mounting the Operators
- Attach the mounting brackets securely to the gate posts and gate leaves according to the dimensions specified in the detailed manual. Precise positioning is critical for correct gate operation.
- Mount the RotaMatic 2 spindle units onto the installed brackets.
- Ensure the operators are level and aligned correctly with the gate's pivot points.
5.3 Elektriske forbindelser
- Install the electronic control unit in a protected location, ensuring its IP 65 rating is maintained.
- Connect the 24V DC power supply to the control unit.
- Wire the spindle units to the control unit as per the wiring diagram in the detailed manual.
- Connect all safety devices (e.g., photocells, warning light) to the control unit.
- Sørg for, at alle elektriske forbindelser er sikre og isolerede.
5.4 Programming and Commissioning
- Tænd for kontrolenheden.
- Follow the programming steps in the detailed manual to set the gate's opening and closing limits, force settings, and any desired operational modes using the 16 DIL switches.
- Program the BiSecur hand transmitters to the integrated radio receiver.
- Perform several test cycles to ensure smooth operation and proper functioning of all safety features.
6. Betjeningsvejledning
The Hormann RotaMatic 2 SK BiSecur gate operator is designed for user-friendly operation, primarily via the provided hand transmitters.
6.1 Using the Hand Transmitter

Figur 6.1: Hormann BiSecur hand transmitter.
- Åben luk: Press the programmed button on your hand transmitter once to initiate the gate's movement. If the gate is closed, it will open. If it is open, it will close. If it is in motion, it will stop.
- Stop: Pressing the button again while the gate is in motion will stop the gate.
- Partial Opening (if programmed): Some transmitters may have a button programmed for partial opening (e.g., for pedestrian access). Consult your detailed manual for specific programming.
6.2 Manuel udløsning
In case of power failure or operator malfunction, the gate can be operated manually. Locate the manual release mechanism on each spindle unit (refer to the detailed manual for exact location and procedure). Engage the release to disengage the operator, allowing the gate to be opened or closed by hand. Remember to re-engage the operator once power is restored or the issue is resolved.
7. Vedligeholdelse
Regular maintenance ensures the longevity and reliable operation of your Hormann RotaMatic 2 SK BiSecur gate operator. Perform these checks periodically.
- Visuel inspektion (månedlig): Check the gate and operator for any signs of wear, damage, or corrosion. Ensure all mounting hardware is tight.
- Gate Movement (Quarterly): Manually operate the gate to ensure it moves freely without excessive friction or binding. Lubricate hinges if necessary.
- Safety Devices (Quarterly): Test all safety devices, such as photocells and the warning light, to ensure they are functioning correctly.
- Rensning: Keep the operator housing and photocell lenses clean and free from debris.
- Professionel service (årligt): It is recommended to have a qualified technician inspect and service your gate operator system annually.
CAUTION: Always disconnect power to the operator before performing any maintenance or cleaning.
8. Fejlfinding
This section addresses common issues you might encounter with your gate operator. For more complex problems, consult the detailed installation manual or contact customer support.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Porten reagerer ikke på fjernbetjeningen. |
|
|
| Porten stopper uventet under drift. |
|
|
| Porten åbner/lukker delvist. |
|
|
9. Garanti og support
The Hormann RotaMatic 2 SK BiSecur Swing Gate Operator Kit is manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact Hormann customer service directly.
In case of technical issues or if you require professional assistance, please contact your authorized Hormann dealer or the manufacturer's support line. Do not attempt to repair the unit yourself, as this may void your warranty and pose safety risks.
For further information, you may visit the official Hormann website or consult the comprehensive installation manual provided with your kit.