The Einhell GC-WW 6538 Domestic Water Supply Plant is designed to efficiently draw purified water from various sources such as reservoirs, wells, and fountains. It is ideal for supplying service water to irrigation systems, cleaning equipment, toilet cisterns, and other domestic applications. This robust unit features a 650W motor capable of pumping up to 3800 liters of water per hour.
The system includes a 20-liter pressure boiler, which minimizes pump activation by storing a reserve of water. An integrated pressure switch automatically turns the pump on when pressure drops and off once the maximum pressure is reached. A built-in pressure gauge allows for easy monitoring of the system's pressure.

Figure 1.1: The Einhell GC-WW 6538 Domestic Water Supply Plant, showcasing its red tank and black pump housing.
2. Opsætning og installation
Proper setup is crucial for the optimal performance and longevity of your domestic water supply plant. Ensure the unit is placed on a stable, level surface in a dry, well-ventilated area, protected from frost and direct sunlight.
2.1. Placering
Position the unit as close as possible to the water source to minimize suction lift. Ensure there is adequate space around the unit for ventilation and maintenance access.

Figur 2.1: Eksample installation of the Einhell GC-WW 6538 in a utility area, demonstrating typical placement near a washing machine.
2.2. Forbindelser
Connect the suction line from your water source to the pump's inlet. Ensure all connections are airtight to prevent air from entering the system, which can affect performance. Connect the pressure line from the pump's outlet to your domestic water supply system (e.g., irrigation, toilet cisterns).

Figure 2.2: Schematic diagram illustrating the connections for the water supply plant, including the 20-liter tank and pipe fittings.
2.3. Initial Filling
Before first use, the pump must be filled with water. Locate the water filling screw on the pump housing. Unscrew it and fill the pump completely with water until it overflows. Replace the screw tightly.

Figure 2.3: Detail of the water filling screw, located on the top of the pump housing, used for priming the unit.
3. Betjeningsvejledning
Once properly installed and filled, the Einhell GC-WW 6538 operates largely automatically.
3.1. Tænder
Connect the power cord to a suitable electrical outlet (240 Volts). The integrated pressure switch will monitor the system pressure.
3.2. Automatisk drift
The pump will automatically activate when the pressure in the system drops below a preset minimum (e.g., when a tap is opened). It will then pump water until the maximum pressure is reached, at which point it will automatically shut off. This ensures efficient operation and reduces wear on the pump.

Figur 3.1: Nærbillede view of the integrated pressure switch and the pressure gauge, key components for automatic operation.
3.3. Monitoring Pressure
The built-in pressure gauge provides a real-time reading of the system pressure. This allows you to quickly assess the operational status of the unit.

Figur 3.2: Detaljeret view of the pressure gauge, indicating pressure in both PSI and Bar units.
4. Vedligeholdelse
Regular maintenance ensures the long-term reliability and performance of your Einhell GC-WW 6538.
4.1. Vandafledning
For periods of non-use, especially during freezing temperatures, it is essential to completely drain the water from the pump and tank to prevent damage. Use the water bleed screw for convenient emptying of residual water.

Figure 4.1: Symbolic representation of the water drain plug, indicating the point for complete water removal.
4.2. Rensning
Hold enhedens yderside ren og fri for støv og snavs. Brug ikke skrappe kemikalier eller slibende rengøringsmidler.
4.3. Frostbeskyttelse
If the unit is installed in an area prone to freezing, ensure it is either drained completely or adequately protected from frost to prevent internal damage.
5. Fejlfinding
This section provides guidance for common issues you might encounter with your domestic water supply plant.
5.1. No Water Flow / Low Pressure
- Check Water Source: Ensure the water source (well, reservoir) has sufficient water.
- Check Suction Line: Verify that the suction line is not blocked, kinked, or leaking air. An airtight connection is crucial.
- Forbered pumpen: If the pump was recently drained or installed, ensure it is properly filled with water (primed) as described in Section 2.3.
- Check Pressure Gauge: Observe the pressure gauge. If it reads zero or very low, the pump may not be engaging or there's an issue with water intake.
5.2. Pump Runs Continuously
- Tjek for lækager: Inspect all connections and pipes for leaks in your domestic water system. Even small leaks can cause pressure drops, leading the pump to run constantly.
- Pressure Switch Malfunction: The integrated pressure switch might be faulty or incorrectly set. Consult a qualified technician if you suspect this.
- Insufficient Water Supply: If the water source is running low, the pump may struggle to build pressure and run continuously.
5.3. Usædvanlige lyde
- Luft i systemet: Gurgling or rattling noises often indicate air in the pump or suction line. Re-prime the pump and check for airtight connections.
- Affald: Foreign objects in the pump impeller can cause noise and damage. Disconnect power and inspect if safe to do so, or consult a professional.
For issues not covered here or if troubleshooting steps do not resolve the problem, please contact qualified service personnel.
6. Specifikationer
Detailed technical specifications for the Einhell GC-WW 6538 Domestic Water Supply Plant.
| Feature | Specifikation |
|---|---|
| Modelnummer | 4173190 |
| Strøm (Wattage) | 650 watt |
| Voltage | 240 volt |
| Maksimal flowhastighed | 3800 liter i timen |
| Maksimalt tryk | 3.6 bar |
| Tankvolumen | 20 liter |
| Maksimalt hoved | 36 meter |
| Maksimal sugehøjde | 8 meter |
| Produktmål (L x B x H) | 19.49 cm x 10.63 cm x 19.88 cm |
| Varens vægt | 22.8 pund (10.38 kilo) |
| Materiale | Metall |
| Farve | Sort Rød |

Figure 6.1: Performance curve illustrating the relationship between head (H) and flow rate (Q) for the pump.
7. Garanti og support
For information regarding warranty coverage, terms, and conditions, please refer to the documentation provided with your purchase or contact the authorized Einhell dealer or customer support directly. Keep your proof of purchase for warranty claims.
For teknisk support, reservedele eller serviceforespørgsler, besøg venligst den officielle Einhell website or contact their customer service department. Always provide the model number (GC-WW 6538) and serial number (if applicable) when seeking support.