1. Introduktion
Thank you for choosing the Project E Beauty LED+ Radio Frequency Ultrasonic Slimming Therapy Device. This manual provides essential information for the safe and effective use of your device. Please read it thoroughly before operation and retain it for future reference.
This device combines LED light therapy, Radio Frequency (RF), and Ultrasonic (Cavitation) technologies to assist in body shaping, skin tightening, and the reduction of cellulite.
2. Produktegenskaber og fordele

Billede: Overview of the device's five key features.
- Radio Frequency (RF) Technology: Accelerates blood circulation, promotes tissue metabolism, and helps to tighten skin and strengthen elasticity. It stimulates collagen production to reduce the appearance of fine lines and loose skin.
- Ultrasonic (Cavitation) Slimming: Utilizes 330KHz ultrasonic waves to break down fat cells, aiding in body shaping and cellulite reduction.
- Red LED Light (625 nm): Reaches the dermis to stimulate fibrous cells, improve blood circulation, and enhance collagen production for firmer, smoother skin texture.
- Extra Large Probe: Designed for efficient treatment across various body areas.
- Trådløs drift: Offers convenience and flexibility during use.

Image: Visual representation of the device's benefits.

Image: Treatment areas for the device.
3. Pakkens indhold
Når du åbner din pakke, skal du sørge for at alle varer er til stede:
- Main Unit (Project E Beauty LED+ RF Ultrasonic Slimming Therapy Device) x 1
- USB-opladerkabel x 1
- Detailed English Instruction Manual x 1
4. Specifikationer

Image: Technical specifications and device diagram.
| Specifikation | Værdi |
|---|---|
| Modelnummer | AHGRD000940 (PE142) |
| Farve | Hvid |
| Input bindtage | 100-240 V |
| Udgangseffekt | Max 11W |
| Ultralydsfrekvens | 330KHz |
| Radiofrekvens | 500KHz |
| Batterikapacitet | 1400mAh |
| Opladningsvarighed | 6 timer (ca.) |
| Auto-sluk-timer | 10 minutter |
| Enhedens dimensioner | 22.4 x 10.2 x 9.5 cm (ca.) |
| Nettovægt | 292 g (10.3 ounce) |
| Behandlingsområde | Legeme |
5. Sikkerhedsoplysninger
- Må ikke anvendes på beskadiget, irriteret eller inficeret hud.
- Avoid use if pregnant, breastfeeding, or if you have a pacemaker, metal implants, or severe medical conditions. Consult a physician if unsure.
- Opbevares utilgængeligt for børn.
- Nedsænk ikke enheden i vand.
- Always use with a conductive gel or cream.
- Hvis du oplever ubehag, skal du straks afbryde brugen.
6. Opsætning og opladning
Before first use, fully charge the device. Connect the USB charging cable to the device and a suitable power adapter. The charging indicator will illuminate. A full charge typically takes approximately 6 hours.
7. Betjeningsvejledning
Følg disse trin for at få optimale resultater:
- Forbered huden: Cleanse the treatment area thoroughly. Apply a generous layer of conductive slimming cream or gel to the skin. This is crucial for the effective transmission of RF and ultrasonic waves.

Image: Applying conductive gel or cream to the treatment area.
- Power On and Select Functions: Press the Power Button to turn on the device. Select your desired functions (RF, CAVI, LED) and intensity levels (Low, Medium, High) using the respective buttons. It is recommended to start with a low energy level and gradually increase as your skin adapts.

Image: The device with its control panel.
- Udfør behandling: Gently place the device head on the prepared skin. Move the device in slow, circular, and upward motions across the treatment area. Ensure continuous contact with the skin. Do not hold the device stationary in one spot.

Image: Illustration of the four easy steps for using the device.
- Treatment Duration and Frequency: The suggested treatment duration is 10-15 minutes per area. For initial use, begin with 10 minutes per day. Once desired results are achieved, you may reduce usage to 3-4 times per week. The device features an automatic shut-off after 10 minutes.
- Efterbehandling: After each session, turn off the device and clean the treatment head. Remove any remaining gel from your skin.
Video: A short demonstration of the Project E Beauty device, including unboxing and application on the body. This video provides a visual guide to the device's appearance and basic usage.

Image: Scientific explanation of the device's mechanism of action.

Billede: Eksamples of visible results from consistent use.
8. Vedligeholdelse og pleje
- After each use, wipe the device head with a soft, damp klud for at fjerne eventuelle gelrester.
- Brug ikke slibende rengøringsmidler eller stærke kemikalier.
- Opbevar enheden på et køligt, tørt sted, væk fra direkte sollys og fugt.
- Sørg for, at enheden er fuldt opladet inden langtidsopbevaring for at bevare batteriets tilstand.
9. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Enheden tænder ikke | Lavt batteri eller ikke opladet | Oplad enheden helt. Sørg for, at opladningskablet er korrekt tilsluttet. |
| No sensation or heat during treatment | Insufficient conductive gel or low intensity setting | Apply more conductive gel. Increase the intensity level gradually. Ensure continuous contact with skin. |
| Device automatically shuts off | Automatic 10-minute timer or low battery | This is normal operation due to the built-in timer. If it shuts off before 10 minutes, recharge the device. |
| Rødme eller irritation i huden | High intensity setting or sensitive skin | Reduce the intensity level. Ensure the device is constantly moving. If irritation persists, discontinue use. |
10. Garanti og support
All Project E Beauty products come with a comprehensive one-year warranty against manufacturing defects. Our customer service team is available to assist with any inquiries within 12 business hours.
For support, please visit the official Project E Beauty store or contact customer service via the details provided on the product packaging or official webwebsted.