BENETECH GM900

BENETECH GM-900 Infrared Thermometer User Manual

Model: GM-900 | Brand: BENETECH

Indledning

This user manual provides comprehensive instructions for the safe and effective operation of the BENETECH GM-900 Infrared Thermometer. This device is designed for non-contact temperature measurement, offering a wide temperature range and various advanced features for accurate readings.

The GM-900 is suitable for measuring surface temperatures of objects that are hazardous to approach or inaccessible, such as high-voltage parts or moving machinery. Its precise laser targeting ensures accurate measurement.

Produkt overview

BENETECH GM-900 Infrared Thermometer, main view with display inset

Figur 1: Hoved view of the BENETECH GM-900 Infrared Thermometer, showing the full device and a detailed inset of its LCD display.

Close-up of the BENETECH GM-900 LCD display

Figur 2: Nærbillede view of the GM-900's LCD display, showing temperature readings, emissivity setting, battery indicator, and hold function.

Side view of the BENETECH GM-900 Infrared Thermometer

Figur 3: Side view of the GM-900, highlighting its ergonomic design and trigger.

The BENETECH GM-900 features a clear LCD display with backlight, intuitive button controls for settings like emissivity and unit selection, and a comfortable ergonomic grip. It includes a laser pointer for precise targeting of measurement areas.

Opsætning

1. Batteriinstallation

  1. Find batterirummet på termometerets håndtag.
  2. Gently pull the handle cover downwards to open the compartment.
  3. BENETECH GM-900 with battery compartment open

    Figur 4: Battery compartment opened, showing terminals for 9V battery.

  4. Insert one 9V battery (not included) into the compartment, ensuring correct polarity (+/-).
  5. Luk batterirummet forsvarligt.

2. Første opstart

After battery installation, press the trigger to power on the device. The LCD display will illuminate.

Betjeningsvejledning

1. At foretage en måling

  1. Point the thermometer at the target object. Ensure the target fills the measurement spot as much as possible. Refer to the Distance to Spot Ratio (D:S) in the Specifications section.
  2. Press and hold the trigger. The temperature reading will appear on the LCD display instantly.
  3. Release the trigger to hold the reading on the display (Data Hold Function). The "HOLD" icon will appear.

2. Unit Selection (°C/°F)

Tryk på ° C / ° F button (usually located near the display) to switch between Celsius and Fahrenheit temperature units.

3. Justering af emissivitet

Emissivity (EMS) is crucial for accurate infrared temperature measurement. The GM-900 allows adjustment from 0.10 to 1.00 (default is 0.95).

  1. Tryk på SÆT button to enter emissivity adjustment mode.
  2. Use the Up/Down arrow buttons to increase or decrease the emissivity value.
  3. Trykke SÆT igen for at bekræfte og afslutte.

4. Laserpointer

The laser pointer assists in targeting the measurement area. Press the laser button (often depicted with a laser icon) to toggle the laser on or off.

5. Baggrundsbelysning

Press the backlight button (often depicted with a light bulb icon) to toggle the LCD backlight on or off for better visibility in different lighting conditions.

6. Advanced Functions (MODE Button)

De MODE button cycles through various measurement functions:

  • MAKS: Viser den maksimale temperatur, der er registreret under en kontinuerlig scanning.
  • MIN: Viser den minimumstemperatur, der er registreret under en kontinuerlig scanning.
  • AVG: Viser den gennemsnitlige temperatur, der er registreret under en kontinuerlig scanning.
  • DIF: Viser forskellen mellem de registrerede maksimum- og minimumtemperaturer.
  • HAL (High Alarm): Set a high temperature alarm. If the measured temperature exceeds this value, an alarm will sound.
  • LAL (Low Alarm): Set a low temperature alarm. If the measured temperature falls below this value, an alarm will sound.
  • STO (Storage): Access memory storage (up to 12 data points).

To set alarm values, select HAL or LAL mode, then use the Up/Down arrow buttons to adjust the threshold. Press SÆT for at bekræfte.

Opretholdelse

1. Rengøring af linsen

The infrared lens is the most delicate part of the thermometer. Clean it carefully with a soft cloth or cotton swab and water, or medical alcohol. Do not use abrasive cleaners or solvents.

2. Rengøring af Casing

Clean the thermometer casing med annonceamp cloth and mild soap. Do not immerse the device in water.

3. Opbevaring

Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.

Fejlfinding

ProblemMulig årsagLøsning
Enheden tænder ikke.Lavt eller dødt batteri; forkert batteriinstallation.Replace the 9V battery. Ensure correct polarity.
Upræcise aflæsninger.Incorrect emissivity setting; lens is dirty; target too far or too small.Adjust emissivity for the target material. Clean the lens. Ensure target fills the measurement spot.
Laserpointeren virker ikke.Laser function is turned off.Press the laser button to activate.
Skærmen er svag eller flimrer.Lavt batteri.Udskift 9V batteriet.

Specifikationer

ParameterVærdi
Temperaturområde-50 ~ 950 ° C (-58 ~ 1742 ° F)
Nøjagtighed±1.5 °C or ±1.5% (0°C to 950°C); ±3 °C (-50°C to 0°C)
Opløsning0.1 ° C eller 0.1 ° F
Gentagelighed1 % or 1 °C
Svartid500 ms (0.5 seconds), 95% response
Spektral respons (bølgelængde)8 ~ 14 µm
Afstand til punktforhold (D:S)12:1
emissivitet0.10 ~ 1.00 (Adjustable, Preset at 0.95)
Driftstemperatur0 ~ 40 ° C (32 ~ 104 ° F)
Opbevaringstemperatur-20 ~ 60 °C (-4 til 140 °F)
Relativ luftfugtighed10 ~ 95% R.H. non-condensing, up to 30 °C
Magt1 x 9V batteri (medfølger ikke)
Batterilevetid22 hours (Non-Laser Mode), 12 hours (Laser Mode)
Mål (L x B x D)approx. 175 x 100 x 49 mm (6.89 x 3.94 x 1.93 inch)
Vægt (uden batteri)ca. 226 g (7.97 oz)

Garanti og support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact BENETECH customer service. Keep your purchase receipt as proof of purchase.

For further assistance, please visit the official BENETECH webwebstedet eller kontakt deres autoriserede servicecentre.

Relaterede dokumenter - GM900

Preview Benetech GM 550 Infrared Thermometer User Manual
User manual and specifications for the Benetech GM 550 infrared thermometer, covering its operation, features, safety, and technical details. Includes guidance on measurement distance, emissivity, power, maintenance, and proper disposal.
Preview Benetech GM1651 infrarødt termometer: Brugermanual og specifikationer
Omfattende guide til Benetech GM1651 infrarødt termometer, der dækker sikker betjening, funktioner, tekniske specifikationer og vedligeholdelse for nøjagtig berøringsfri måling af overfladetemperatur.
Preview Benetech GM1150 Infrared Thermometer User Manual
User manual and specifications for the Benetech GM1150 non-contact infrared thermometer, covering introduction, warnings, operation, maintenance, and technical details.
Preview BENETECH GM1651 Infrarødt termometer Instruktionsmanual
Omfattende brugsanvisning til BENETECH GM1651 infrarødt termometer, der dækker introduktion, advarsler, betjening, vedligeholdelse, specifikationer og LCD-displayfunktioner.
Preview BENETECH GM321/GM531 Infrarødt termometer: Brugsanvisning og specifikationer
Omfattende brugsanvisning til BENETECH GM321 og GM531 infrarøde termometre. Dækker produktintroduktion, sikkerhedsadvarsler, betjening, afstand til punktstørrelse, emissivitet, LCD-display, vedligeholdelse og detaljerede specifikationer.
Preview BENETECH GM1150 Infrarødt Termometer - Specifikationer og Funktioner
Detaljeret information om BENETECH GM1150 infrarødt termometer, herunder specifikationer, funktioner og betjeningsvejledning.