1. Introduktion
This manual provides essential information for the proper installation, operation, and maintenance of the Hach Filter Assembly, Model 1187R27EA. This assembly is specifically designed for use with the Hach 2100AN Laboratory Turbidimeter to ensure accurate and reliable turbidity measurements, particularly when adhering to USEPA Method 180.1 reporting requirements. Proper use of this filter assembly contributes to the precision and longevity of your turbidimeter system.
2. Sikkerhedsoplysninger
Always observe standard laboratory safety practices when handling the filter assembly and operating the turbidimeter. Refer to the Hach 2100AN Laboratory Turbidimeter user manual for comprehensive safety guidelines.
- Brug passende personlige værnemidler (PPE) såsom handsker og øjenbeskyttelse.
- Ensure the turbidimeter is powered off and disconnected from the power source before installing or removing the filter assembly.
- Handle components carefully to avoid damage or contamination.
3. komponenter
The Hach Filter Assembly typically includes the filter housing and the replaceable filter element. Verify all components are present and undamaged upon receipt.

Figure 1: Hach Filter Assemblies. These units are designed for precise filtration within laboratory turbidimeters.
4. Opsætning og installation
Follow these steps to properly install the filter assembly into your Hach 2100AN Laboratory Turbidimeter:
- Sluk: Ensure the Hach 2100AN Turbidimeter is turned off and unplugged from the power source.
- Find filterrummet: Refer to your turbidimeter's manual to identify the specific location for the filter assembly. This is typically a dedicated slot or chamber.
- Insert Filter Assembly: Carefully align the filter assembly with the designated slot. Gently push the assembly into place until it is securely seated. Avoid forcing the assembly.
- Bekræft forbindelsen: Ensure the assembly is fully inserted and any locking mechanisms (if present) are engaged. A loose connection can lead to inaccurate readings or leaks.
- Tænd: Once the filter assembly is securely installed, reconnect the turbidimeter to power and turn it on.
5. Betjening
The filter assembly plays a crucial role in preparing samples for turbidity measurement. Its primary function is to remove particulate matter that could interfere with accurate readings or damage the turbidimeter's optical system. Once installed, the filter assembly operates passively as part of the sampstrømningsvejen.
- SampForberedelse: Sørg for samples are prepared according to USEPA Method 180.1 guidelines and any specific instructions for your turbidimeter.
- Måling: Proceed with turbidity measurements as outlined in the Hach 2100AN Turbidimeter manual. The filter assembly will condition the sample as it passes through.
- Overvågning: Regularly monitor the performance of the turbidimeter. A decrease in flow rate or inconsistent readings may indicate a clogged filter.
6. Vedligeholdelse
Regular maintenance of the filter assembly is essential for optimal performance and accurate results.
6.1. Rensning
- Frekvens: Clean the filter assembly as needed, or at recommended intervals specified by Hach for your application.
- Procedure: Disconnect the turbidimeter from power. Carefully remove the filter assembly. Rinse the exterior with deionized water. For internal cleaning, follow specific instructions provided by Hach for the filter element type. Avoid abrasive cleaners.
6.2. Udskiftning af filter
- Indikatorer: Replace the filter element when there is a noticeable decrease in sample flow, persistent inconsistent readings, or if the filter appears visibly clogged or damaged.
- Procedure: Power off and unplug the turbidimeter. Remove the filter assembly. Disassemble the housing (if applicable) to access the filter element. Replace with a genuine Hach replacement filter. Reassemble and reinstall the filter assembly.
7. Fejlfinding
If you encounter issues with your Hach Filter Assembly, consider the following:
- Lav Sample Flow: Check for blockages in the sample lines or a clogged filter element. Replace the filter if necessary.
- Inkonsekvente læsninger: Ensure the filter assembly is correctly installed and not leaking. Verify the filter element is clean and not expired.
- Lækage: Confirm all connections are tight and O-rings (if present) are properly seated and undamaged.
For persistent issues, refer to the Hach 2100AN Turbidimeter manual or contact Hach technical support.
8. Specifikationer
| Attribut | Detalje |
|---|---|
| Produkttype | Lab Supply |
| Modelnummer | 1187R27EA |
| Kompatibilitet | Hach 2100AN Laboratory Turbidimeter |
| Method Compliance | USEPA Method 180.1 |
| Pakkemængde | 1 |
| Oprindelsesland | USA |
| Pakkevægt | 0.04 ounce (ca.) |
| Pakkedimensioner | 1 x 1 x 1 tommer (ca.) |
9. Garantioplysninger
For detailed warranty information regarding the Hach Filter Assembly, please refer to the documentation provided with your purchase or visit the official Hach Company webwebsted. Garantivilkår og -betingelser kan variere.
10. Kundesupport
If you require technical assistance, have questions about the Hach Filter Assembly, or need to order replacement parts, please contact Hach Company customer support: