This manual provides detailed instructions for the installation, operation, and maintenance of your LUX LV11 Line Voltage Heat Only Single Pole Thermostat. The LV11 is designed for use with 120 Volt and 240 Volt heating systems, including baseboard heaters, ceiling cable, and other radiant heat applications. It is a mechanical thermostat intended for controlling heating systems only.
2. Sikkerhedsoplysninger
ADVARSEL: Fare for elektrisk stød
- Always turn off power to the heating system at the main circuit breaker or fuse box before installing or servicing this thermostat. Failure to do so can result in electrical shock, property damage, or death.
- This thermostat is designed for line voltage applications. If you are unfamiliar with electrical wiring, it is recommended to consult a qualified electrician for installation.
- Sørg for, at alle ledningsforbindelser er sikre og overholder lokale el-forskrifter.
- Do not use this thermostat for applications other than those specified.
3. Pakkens indhold
- LUX LV11 Linjevolumentage Termostat
- Installations- og betjeningsvejledning (dette dokument)
- Monteringsskruer
4. Specifikationer
| Model | LV11 |
| Type | Line Voltage, Heat Only, Single Pole |
| Voltage | 120V / 240V AC |
| Ampslette | 22 Amps |
| Hestekræfter vurdering | 1/2 HK @ 120V |
| Dimensioner (H x B x D) | 4.5" x 2.75" x 1.5" (11.43 cm x 6.98 cm x 3.81 cm) |
| Vægt | 8.8 ounce (249 gram) |
| Controller type | Mekanisk knap |
| Certificering | ETL Certified (USA, Canada) |
| Kviksølv indhold | Ingen |
5. Opsætning og installation
The LUX LV11 thermostat is designed for easy installation, replacing most single pole line voltage thermostats. Follow these steps carefully:
- Sluk for strømmen: Locate the circuit breaker or fuse that controls your heating system and turn it off. Verify that the power is off before proceeding.
- Fjern gammel termostat: Carefully remove your existing thermostat from the wall. Disconnect the wires, noting which wire was connected to which terminal if applicable.
- Identificér ledninger: The LV11 is a single pole, 2-wire thermostat. You will typically have two line voltage wires coming from the wall. One is the incoming power (LINE) and the other goes to the heater (LOAD).
- Tilslut ledninger: Connect the two line voltage wires from the wall to the two terminals on the back of the LV11 thermostat. The LV11 is non-polarized, so the order of connection for these two wires does not matter. Ensure connections are tight and secure.
- Monter termostat: Gently push any excess wire back into the wall opening. Mount the LV11 thermostat to the wall using the provided screws. Ensure it is level and securely fastened.
- Gendan strøm: Once the thermostat is securely mounted and all connections are verified, restore power to the heating system at the main circuit breaker or fuse box.

6. Betjening
The LUX LV11 thermostat features a simple mechanical knob for temperature control.
- Justering af temperatur: To adjust the desired room temperature, rotate the central knob.
- Warmer Setting: Turn the knob clockwise towards the 'WARMER' indication to increase the set temperature.
- Cooler Setting: Turn the knob counter-clockwise towards the 'COOLER' indication to decrease the set temperature.
- LO Setting: The 'LO' setting indicates the lowest possible temperature setting, typically used for minimal heat or frost protection.
The thermostat will automatically turn your heating system on or off to maintain the set temperature.
7. Vedligeholdelse
The LUX LV11 thermostat requires minimal maintenance.
- Rensning: For at rengøre termostaten skal du forsigtigt tørre ydersiden af med en blød klud.amp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Ingen kviksølv: This thermostat contains no mercury, making it an environmentally responsible choice.
- Interne komponenter: There are no user-serviceable parts inside the thermostat. Do not attempt to open the unit.
8. Fejlfinding
If you experience issues with your LUX LV11 thermostat, consider the following common solutions:
- Ingen varme:
- Check if the circuit breaker for your heating system is tripped. Reset if necessary.
- Ensure the thermostat knob is set to a temperature higher than the current room temperature.
- Verify that the wiring connections are secure at the thermostat and the heating unit.
- Inkonsekvent temperatur:
- Ensure the thermostat is not located near heat sources (e.g., direct sunlight, lamps, appliances) or drafts (e.g., windows, doors). These can affect its ability to accurately sense room temperature.
- Confirm the thermostat is securely mounted to the wall.
- Termostaten reagerer ikke:
- Turn off power to the thermostat at the circuit breaker for 5 minutes, then restore power.
- Recheck all wiring connections.
Hvis problemerne fortsætter efter at have forsøgt disse løsninger, skal du kontakte kundesupport.