Allied Telesis AT-GS950/24-10

Allied Telesis AT-GS950/24-10 WebSmart Switch brugermanual

Model: AT-GS950/24-10

Produkt overview

The Allied Telesis AT-GS950/24 is a 24-port Gigabit WebSmart Switch designed for small to medium-sized networks. It features 24 x 10/100/1000Base-T ports and 2 x SFP ports, offering flexible connectivity options. This managed switch provides essential features for network control and monitoring, making it suitable for various desktop and rack-mount installations.

Front view of the Allied Telesis AT-GS950/24-10 WebSmart Switch, showing 24 Ethernet ports, 2 SFP ports, LED indicators, and a console port.

Figure 1: Front panel of the AT-GS950/24-10 WebSmart Switch, illustrating the Ethernet ports, SFP slots, and status indicators.

Opsætningsvejledning

Follow these steps to properly set up your AT-GS950/24-10 WebSmart Switch:

  1. Udpakning og inspektion: Carefully remove the switch from its packaging. Verify that all components are present and undamaged.
  2. Monteringsmuligheder:
    • Desktopplacering: Place the switch on a flat, stable surface with adequate ventilation.
    • Rack montering: Use the provided wall and 19-inch rack mount brackets to secure the switch in a standard equipment rack. Ensure proper airflow around the unit.
  3. Strømtilslutning: Tilslut netledningen til afbryderens strømindgang og derefter til en jordet stikkontakt.
  4. Netværksforbindelser:
    • Connect Ethernet cables from your network devices (computers, servers, other switches) to the 10/100/1000Base-T ports (ports 1-24) on the front panel.
    • For fiber optic connections, insert compatible SFP transceivers into the SFP ports (ports 23-24) and connect fiber optic cables.
  5. Initial Configuration (Optional): For initial management access, connect a computer to any Ethernet port or use the console port with a serial cable. Refer to the detailed configuration guide for WebSmart interface setup.

Betjeningsvejledning

Once the switch is powered on and connected, it will begin operating. Here are key aspects of its operation:

  • Tænd: After connecting the power, the switch will automatically power on. The MAGT LED indicator on the front panel should illuminate.
  • LED-indikatorer: Observe the LED indicators for each port:
    • Link/Act LED: Indicates a valid network link (solid green) and network activity (blinking green).
    • Hastighed LED: Indicates the connection speed (e.g., green for Gigabit, amber for 100Mbps, off for 10Mbps - consult the full manual for exact color codes).
  • WebSmart styring: Switchen kan styres via en web-based interface. Access this interface by typing the switch's IP address into a web browser. This allows for configuration of VLANs, QoS, port mirroring, and other advanced features.
  • Plug-and-Play-funktionalitet: For basic network connectivity, the switch operates as a plug-and-play device, automatically detecting connected devices and negotiating speeds.

Opretholdelse

Proper maintenance ensures the longevity and optimal performance of your switch:

  • Rensning: Rengør regelmæssigt ydersiden af ​​kontakten med en blød, tør klud. Brug ikke flydende rengøringsmidler eller rengøringsmidler på sprayform. Sørg for, at ventilationsåbningerne er fri for støv og blokeringer.
  • Firmwareopdateringer: Periodically check the Allied Telesis webwebsted for firmwareopdateringer. At holde firmwaren opdateret kan forbedre ydeevnen, tilføje nye funktioner og afhjælpe sikkerhedssårbarheder.
  • Miljøforhold: Ensure the switch operates within its specified temperature and humidity ranges. Avoid placing it near heat sources or in direct sunlight.
  • Kabelstyring: Organize network cables to prevent tangles and ensure proper airflow.

Fejlfinding

If you encounter issues with your switch, consider the following troubleshooting steps:

ProblemMulig årsagLøsning
Ingen Power LEDPower cord disconnected; Power outlet issue; Switch malfunction.Check power cord connection; Try a different power outlet; Contact support if issue persists.
No Link/Act LED on portCable not connected; Faulty cable; Device not powered on; Incorrect port settings.Ensure cable is securely connected; Replace cable; Power on connected device; Check switch port configuration via WebSmart interface.
Langsom netværkshastighedCable issue; Port speed mismatch; Network congestion; Duplex mismatch.Verify cable quality (use Cat5e/6 for Gigabit); Check port speed settings on both switch and device; Monitor network traffic; Ensure duplex settings match.
Kan ikke få adgang WebSmart interfaceIncorrect IP address; Network configuration issue; Browser problem.Verify switch IP address; Ensure your computer is on the same subnet; Try a different web browser; Reset switch to factory defaults if necessary (consult full manual).

Specifikationer

FeatureDetalje
ModelnummerAT-GS950/24-10
MærkeAllied Telesis
Dataoverførselshastighed1000 megabit pr. sekund (Gigabit Ethernet)
Antal havne24 x 10/100/1000Base-T, 2 x SFP
Switch TypeAdministreret (WebSmart)
Interface TypeEthernet, SFP
Produktdimensioner10 x 17 x 2 tommer
Varens vægt7.2 pund
UPC012302361338, 767035178431
ASINB00PB4VLZI
Dato først tilgængelig6. november 2014

Garantioplysninger

The Allied Telesis AT-GS950/24-10 WebSmart Switch comes with a Livsvarig producentgaranti. This warranty covers defects in materials and workmanship under normal use and service. For specific terms, conditions, and limitations, please refer to the official warranty documentation provided by Allied Telesis or visit their official webwebsted.

Støtte

For technical assistance, product documentation, or further inquiries regarding your Allied Telesis AT-GS950/24-10 WebSmart Switch, please contact Allied Telesis customer support. You can typically find support contact information, FAQs, and additional resources on the official Allied Telesis webwebsted.

It is recommended to have your product model number (AT-GS950/24-10) and serial number ready when contacting support.

Relaterede dokumenter - AT-GS950/24-10

Preview Allied Telesis iGS950-serien Web Brugervejledning til browser
Omfattende brugervejledning til Allied Telesis iGS950-serien Layer 2 Gigabit Ethernet PoE+ WebSmarte afbrydere, detaljering web Browseradministrationsfunktioner, konfiguration og betjening for modellerne AT-iGS950/10PS, AT-iGS950/20PS, AT-iGS950/28PS og AT-iGS950/52PS.
Preview Allied Telesis GS950PS V2 Series Gigabit WebSmart Ethernet-switches – hurtig installationsvejledning
Lyninstallationsvejledning til Allied Telesis GS950PS V2-serien Gigabit WebSmarte Ethernet-switche, der dækker frontpaneler, PoE+ strømbudgetter, installation, porte, tænding, administrationssessioner, LED'er og fejlfinding.
Preview Allied Telesis GS970M-seriens kommandoreference til AlliedWare Plus
Omfattende kommandoreference til Allied Telesis GS970M-serien af ​​administrerede Gigabit Ethernet-switche, der kører AlliedWare Plus-operativsystemet version 5.4.7-1.x. Dækker CLI-navigation, file administration, brugeradgang og avancerede netværksfunktioner.
Preview Installationsvejledning til Allied Telesis x250 & SE250-serien af ​​10 Gbps Layer 2-administrerede switche
This installation guide provides comprehensive instructions for setting up and configuring the Allied Telesis x250 and SE250 Series 10 Gigabit Layer 2 Managed Switches. It covers hardware installation, Virtual Chassis Stacking (VCStack), software configuration, and troubleshooting for models including x250-18XS, x250-28XS, x250-18XTm, x250-28XTm, SE250-18XS, SE250-28XS, SE250-18XTm, and SE250-28XTm, running AlliedWare Plus.
Preview Allied Telesis TQ7403 trådløst adgangspunkt version 10.0.5-0.2 softwareudgivelsesnoter
Dette dokument indeholder udgivelsesnoter til Allied Telesis TQ7403 Wireless Access Point, version 10.0.5-0.2. Det beskriver understøttede platforme, løste problemer, kendte problemer, begrænsninger, specifikationer med Channel Blanket (AWC-CB) og understøttede lande.
Preview CentreCOM GS970M-serien Hurtig installationsvejledning
Lyninstallationsvejledning til Allied Telesis CentreCOM GS970M-serien af ​​Gigabit Ethernet-switche, der dækker frontpaneler, PoE+ strømforbrugsbudgetter, installationsmuligheder, portdetaljer og fejlfinding.