1. Introduktion og overview
The Beckhoff BK5200 DeviceNet Bus Coupler is designed to connect the DeviceNet bus system to electronic terminal blocks, allowing for modular expansion of industrial control systems. This unit serves as a crucial interface for data exchange within a DeviceNet network.
The BK5200, along with its variants BK5210 and BK5220, forms a complete unit comprising the Bus Coupler, up to 64 standard terminals, and an end terminal. The BK5210 "Economy" variant offers a cost-effective solution for peripheral interfacing, supporting up to 64 digital input/output terminals.
For more extensive applications, the BK5220 "Economy plus" utilizes K-bus extension technology, enabling the connection of up to 255 spatially distributed Bus Terminals to a single Bus Coupler. This variant supports all Beckhoff system Bus Terminals and can manage up to 1,020 digital signals and a maximum of 256 analog input and output channels per slave in its full configuration.
Operating on the CAN protocol, the BK52x0 Bus Coupler adheres to the DeviceNet standard, facilitating the integration of various DeviceNet devices into a unified network. DeviceNet's communication object definition is specifically tailored for sensor/actuator data exchange in automation technology.
Configuration and parameterization of the Bus Couplers and Bus Terminals can be performed using the KS2000 configuration set on a PC. Commissioning is also possible without the KS2000, with corresponding EDS data files available for DeviceNet configuration tools.
2. Nøglefunktioner
- DeviceNet Connectivity: Seamlessly integrates with DeviceNet bus systems.
- Modulær udvidelse: Supports up to 64 standard electronic terminal blocks.
- K-bus Extension (BK5220): Connects up to 255 spatially distributed Bus Terminals.
- High I/O Capacity (BK5220): Processes up to 1,020 digital signals and 256 analog I/O channels.
- CAN Protocol Based: Utilizes the robust CAN protocol for communication.
- Fleksibel konfiguration: Parameterizable via KS2000 software or standard DeviceNet configuration tools using EDS files.
- 24Vdc Power Supply: Operates on a standard 24V direct current power source.
3. Opsætning og installation
Proper installation of the BK5200 Bus Coupler is essential for reliable operation. Follow these general guidelines:
3.1 Fysisk installation
Mount the BK5200 on a standard DIN rail. Ensure adequate space for wiring and ventilation. Connect the DeviceNet bus cable to the designated DeviceNet port. Connect the 24Vdc power supply to the power terminals, observing correct polarity.

Figur 1: Vinklet view of the BK5200 DeviceNet Bus Coupler, illustrating its compact design and various connection points.
3.2 Terminal Block Connection
Connect the electronic terminal blocks to the Bus Coupler. The modular design allows for easy addition or removal of terminals as needed. Ensure secure connections for all I/O modules.

Figur 2: Øverst view of the BK5200, highlighting the LED status indicators and the interface for connecting electronic terminal blocks.
3.3 DIP-switchkonfiguration
The BK5200 features DIP switches for setting the DeviceNet MAC ID and baud rate. Refer to the table on the side of the unit for correct switch settings.

Figur 3: Side view of the BK5200, displaying the DIP switches used to configure the DeviceNet MAC ID (DIP 1-6) and baud rate (DIP 7-8). The corresponding baud rate table is also visible.
3.4 Softwarekonfiguration
For advanced parameterization, use the Beckhoff KS2000 configuration software. Alternatively, standard DeviceNet configuration tools can be used with the provided EDS (Electronic Data Sheet) files. Ensure the correct EDS file for the BK5200 is loaded into your configuration software.
4. Betjeningsvejledning
Once installed and configured, the BK5200 operates as a transparent gateway between the DeviceNet network and the connected I/O terminals. Data exchange occurs automatically based on the DeviceNet communication protocol.
4.1 LED-statusindikatorer
Monitor the LED indicators on the top of the unit to ascertain the operational status of the Bus Coupler and the DeviceNet network:
- I/O ERR: Indicates an error with the connected I/O terminals.
- I/O RUN: Indicates normal operation of the I/O terminals.
- FORBINDE: Indicates a successful connection to the DeviceNet network.
- NS (Network Status): Indicates the status of the DeviceNet network.
- BUS OFF: Indicates the DeviceNet bus is off or in an error state.
- MS (Module Status): Indicates the status of the Bus Coupler module itself.
- LØB: Indicates the Bus Coupler is in run mode.
- SAMLET: General status indicator.
Refer to the DeviceNet specification and Beckhoff documentation for detailed interpretations of LED states.
5. Vedligeholdelse
The Beckhoff BK5200 Bus Coupler is designed for robust industrial environments and requires minimal maintenance. However, periodic checks can help ensure long-term reliability:
- Rensning: Keep the unit free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using solvents or abrasive cleaners.
- Forbindelsesintegritet: Periodically inspect all wiring connections (power, DeviceNet, terminal blocks) to ensure they are secure and free from corrosion.
- Miljøforhold: Sørg for, at driftsmiljøet forbliver inden for de angivne temperatur- og fugtighedsområder for at forhindre for tidlig komponentsvigt.
- Firmwareopdateringer: Check the Beckhoff website periodically for any available firmware updates that may improve performance or address known issues. Follow official procedures for any updates.
6. Fejlfinding
If you encounter issues with your BK5200 Bus Coupler, consult the following troubleshooting guide:
6.1 Strømproblemer
- Ingen strøm: Verify the 24Vdc power supply is active and correctly connected to the terminals. Check for blown fuses in the power circuit.
6.2 DeviceNet Communication Issues
- NS/BUS OFF LED: If the Network Status (NS) or Bus Off LED indicates an error, check the DeviceNet cabling for breaks or shorts. Verify proper termination resistors are in place at both ends of the bus.
- CONNECT LED Off: Ensure the MAC ID and baud rate settings on the DIP switches match the DeviceNet network configuration. Check for duplicate MAC IDs on the network.
- No Data Exchange: Confirm that the EDS file used for configuration matches the BK5200. Verify the DeviceNet master is correctly configured to communicate with the BK5200's MAC ID.
6.3 I/O Terminal Issues
- I/O ERR LED: This indicates an issue with one or more connected I/O terminals. Check the individual terminal blocks for power, wiring errors, or module faults.
- Incorrect I/O Readings: Verify the I/O terminal configuration in your software matches the physical modules connected. Check wiring to sensors/actuators.
For persistent issues, consult the detailed Beckhoff documentation or contact technical support.
7. Specifikationer
| Attribut | Værdi |
|---|---|
| Modelnummer | BK5200 |
| Fabrikant | Beckhoff |
| Produktdimensioner | 6 x 5 x 4 tommer |
| Varens vægt | 1 pund |
| Strømforsyning | 24V jævnstrøm |
| Bus system | DeviceNet (CAN protocol) |
| Max Terminals (BK5200/BK5210) | Op til 64 |
| Max Terminals (BK5220) | Up to 255 (spatially distributed) |
| Max Digital Signals (BK5220) | 1,020 |
| Max Analog I/O Channels (BK5220) | 256 |
| Dato først tilgængelig | 20. oktober 2014 |
| ASIN | B00OPHN2BI |

Figur 4: Nederst view of the BK5200, displaying the product label with essential information such as model number, manufacturer, and certifications.
8. Support og garanti
For technical support, detailed documentation, or warranty information regarding your Beckhoff BK5200 DeviceNet Bus Coupler, please contact Beckhoff Automation directly or visit their official webwebsted.
Beckhoff Automation Official Webwebsted: www.beckhoff.com
Always refer to the latest documentation provided by the manufacturer for the most accurate and up-to-date information on installation, operation, and troubleshooting.