The True 842132 Overload Protector is a critical safety component designed for use in True refrigeration systems. Its primary function is to protect the compressor motor from damage caused by excessive current draw, which can occur due to various operational issues such as low voltage, high head pressure, or mechanical binding. By automatically disconnecting power when an overload condition is detected, this device helps to prevent costly repairs and extend the lifespan of the refrigeration unit. This manual provides essential information for the proper handling, installation, and understanding of this component.

Sikkerhedsoplysninger

Always prioritize safety when working with electrical components and refrigeration equipment. Failure to follow these safety guidelines can result in electric shock, personal injury, or damage to equipment.

  • Afbryd strømmen: Always ensure that the main power supply to the refrigeration unit is disconnected and locked out before attempting any installation, maintenance, or inspection.
  • Kvalificeret personale: Installation and servicing should only be performed by qualified and certified refrigeration technicians or electricians.
  • Korrekt værktøj: Brug passende isoleret værktøj til elektrisk arbejde.
  • Komponentkompatibilitet: Ensure that the replacement overload protector is the correct part number (842132) and is compatible with your specific True refrigeration model.
  • Undgå kontakt: Do not touch electrical terminals or wiring with bare hands when power is connected.

Produkt overview

True 842132 Overload Protector with electrical connections

Figure 1: True 842132 Overload Protector

This image displays the True 842132 Overload Protector, a black cylindrical component with a curved black wire connecting two terminals. One terminal features a screw and nut for secure attachment, while the other is a spade connector. The component is designed to protect refrigeration compressors from electrical overloads.

Installation

The True 842132 Overload Protector is typically installed directly onto the compressor's electrical terminals. The following steps outline a general installation procedure. Always refer to the specific service manual for your True refrigeration unit for detailed, model-specific instructions.

  1. Strømafbrydelse: Ensure the refrigeration unit is completely disconnected from its power source. Verify with a voltmeter.
  2. Adgangskompressor: Locate and access the compressor compartment, typically at the bottom or rear of the unit.
  3. Identify Overload: Identify the existing overload protector, usually a small, round or rectangular component attached to one of the compressor's electrical terminals.
  4. Fjern gammel komponent: Carefully disconnect the wiring from the old overload protector and remove it from the compressor terminal. Note the orientation and connection points.
  5. Install New Overload: Attach the new True 842132 Overload Protector to the correct compressor terminal. Ensure a secure and proper fit.
  6. Tilslut ledningerne igen: Reconnect the electrical wiring to the new overload protector, ensuring all connections are tight and correct according to the original configuration.
  7. Sikre komponenter: Ensure all components are securely mounted and wiring is routed to prevent pinching or damage.
  8. Gendan strøm: Once installation is complete and verified, restore power to the refrigeration unit. Monitor the unit's operation for proper function.

Vigtig: If you are unsure about any step, consult a qualified technician. Incorrect installation can lead to equipment failure or safety hazards.

Funktion og betjening

The True 842132 Overload Protector operates as a thermal-sensitive switch. It is designed to monitor the current flowing to the compressor motor. If the current exceeds a safe operating limit for a sustained period, the internal bimetallic strip or heating element in the overload protector will heat up and trip, opening the electrical circuit to the compressor. This action prevents the compressor motor from overheating and sustaining permanent damage. Once the overload protector cools down, it will automatically reset, allowing the compressor to attempt to restart. Repeated tripping indicates an underlying issue that requires investigation and repair.

Opretholdelse

The True 842132 Overload Protector is a sealed component and does not require routine maintenance or lubrication. However, periodic visual inspection is recommended as part of a comprehensive refrigeration system maintenance schedule.

  • Visuel inspektion: During routine service, inspect the overload protector for any signs of physical damage, such as cracks, discoloration from overheating, or loose connections.
  • Renhed: Ensure the area around the overload protector is free from dust, debris, or moisture that could impede its function or cause electrical issues.
  • Forbindelsesintegritet: Verify that all electrical connections to the overload protector are secure and free from corrosion.

If any damage or signs of overheating are observed, the overload protector should be replaced by a qualified technician.

Fejlfinding

If your refrigeration unit is experiencing issues related to the compressor, the overload protector may be involved. Here are some common scenarios and potential causes:

  • Compressor Not Starting / Frequent Tripping:
    • Overload Protector Failure: The overload protector itself may be faulty and tripping prematurely or failing to reset.
    • Kompressorproblemer: The compressor motor may be drawing excessive current due to internal mechanical problems (e.g., worn bearings, seized components) or electrical winding issues.
    • Refrigeration System Problems: High head pressure, low refrigerant charge, or restricted airflow over the condenser can cause the compressor to work harder and draw more current.
    • Electrical Supply Issues: Lav voltage or unstable power supply can cause the compressor to draw higher current.
    • Starting Components: Faulty start relay or start capacitor can prevent the compressor from starting correctly, leading to overload tripping.
  • Kompressor kører kontinuerligt: While less common for an overload protector issue, if the overload protector is bypassed or faulty and not tripping when it should, it could lead to compressor overheating and damage.

Note: Troubleshooting refrigeration systems requires specialized knowledge and tools. It is strongly recommended to contact a qualified refrigeration technician for diagnosis and repair.

Specifikationer

AttributVærdi
Mærkeægte
Modelnummer842132
Varenummer842132
Varens vægtCirka 0.16 ounce
OprindelseslandSlovakiet
Produktmål (omtrentlige)6 x 4 x 4 tommer (emballagemål)

Garanti og support

For information regarding the warranty of your True 842132 Overload Protector, please refer to the documentation provided with your True refrigeration unit or contact True Refrigeration directly. Warranty terms typically cover manufacturing defects for a specified period.

For technical support, replacement parts, or service inquiries, please contact True Refrigeration's customer service or an authorized True service provider. When contacting support, have your refrigeration unit's model and serial number, along with the part number (842132) of the overload protector, readily available.

True Refrigeration Contact Information:
Please visit the official True Refrigeration website for the most current contact details, service locator, and support resources.

Relaterede dokumenter - 842132

Preview Installationsmanual til True TH-modeller med varmeskabe
Omfattende installations-, betjenings- og vedligeholdelsesvejledning til True TH-modeller af varmeskabe. Dækker sikkerheds-, elektriske, opsætnings-, vedligeholdelses- og garantioplysninger fra True Manufacturing Co., Inc.
Preview Ægte Kommerzielle Kühltechnik: Allgemeiner Regelungsleitfaden
Umfassender Leitfaden zur Bedienung, Einstellung und Fehlerbehebung von Temperaturregelungen in True kommerziellen Kühl- und Gefriergeräten. Enthält Anleitungen für mechanische und elektroniske Steuerungen sowie speciel modelinformationen.
Preview TRUE Manufacturing Installation Manual Quick Start Guide
This document provides essential installation, operation, and maintenance guidelines for TRUE Manufacturing commercial refrigeration and heating appliances. It includes safety warnings, specifications, setup procedures, and care instructions.
Preview Installationsmanual for True CVM-serien
Omfattende installations-, betjenings- og vedligeholdelsesmanual til True CVM-serien af ​​køleenheder. Dækker sikkerhedsforanstaltninger, elektriske krav, installationsprocedurer, nivellering, forsegling, hyldemontering og generel vedligeholdelse.
Preview Manuel d'Installation et de Démarrage Rapide True
Guide complet pour l'installation, l'utilisation et l'entretien des appareils de réfrigération et de congélation True Manufacturing Co., Inc. Inclut des informations de sécurité essentielles et des ressources pour le support.
Preview Installations- og betjeningsmanual til True T-23DF-HC kommercielt køleskab/fryser
Omfattende installations-, betjenings-, vedligeholdelses- og sikkerhedsvejledning til True T-23DF-HC kommercielt køleskab/fryser med dobbeltkammer. Indeholder fejlfindings-, rengøringsvejledninger og garantioplysninger.