1. Introduktion
The AL-KO HW 6000 FMS Premium Domestic Water Pump is a high-performance system designed for reliable water supply and pressure boosting. It is ideal for drawing rainwater from wells, cisterns, and rainwater tanks, and for enhancing water pressure in domestic, yard, and garden applications. This manual provides essential information for safe installation, operation, and maintenance of your pump.
2. Sikkerhedsoplysninger
Overhold altid følgende sikkerhedsforanstaltninger for at forhindre personskade og skade på udstyret:
- Elektrisk sikkerhed: Ensure the power supply matches the pump's specifications (230V). Always disconnect power before performing any maintenance or installation. Use a ground fault circuit interrupter (GFCI) for outdoor use.
- Vandsikkerhed: Do not pump flammable or corrosive liquids. Ensure all connections are watertight to prevent leaks and electrical hazards.
- Installation: The pump must be installed in a location protected from rain and splashes. Ensure stable placement on a level surface.
- Operation: Never operate the pump dry. The integrated dry-run protection helps, but manual checks are crucial during initial setup.
- Børn og kæledyr: Hold børn og kæledyr væk fra den pumpe, der er i drift.
- Opretholdelse: Only perform maintenance tasks described in this manual. For complex repairs, contact qualified service personnel.
3. Opsætning og installation
Proper installation is crucial for the optimal performance and longevity of your AL-KO HW 6000 FMS Premium pump.
3.1 Udpakning og inspektion
Carefully remove the pump from its packaging. Inspect for any signs of damage during transit. Ensure all components listed in the packing contents are present, including the instruction manual, corner connection, and filter wrench.
3.2 Placering
Place the pump on a firm, level surface. It must be protected from direct weather exposure (rain, splashes). Ensure adequate ventilation around the unit.

Figur 1: Eksample installation of the AL-KO HW 6000 FMS Premium pump in a utility room, demonstrating connections to the household water system.
3.3 Connecting Water Lines
- Sugeledning: Connect a robust, non-kinking suction hose to the pump's suction inlet. Ensure the suction line is completely airtight to prevent air ingress, which can impair pump performance. For optimal self-priming, the suction height should not exceed 8 meters.
- Pressure Line: Connect the pressure line to the pump's outlet. The included corner connection and check valve should be used to prevent backflow and maintain pressure.
- Spædning af pumpen: Before initial operation, fill the pump housing completely with water through the designated filling opening until no more air bubbles emerge. This is essential for self-priming.
3.4 Elektrisk tilslutning
Connect the pump to a properly grounded 230V power outlet. Ensure the electrical circuit is protected by a residual current device (RCD/GFCI) for safety, especially in damp environments or outdoor installations.
4. Betjening
The AL-KO HW 6000 FMS Premium pump features intelligent electronic control for efficient and safe operation.
4.1 Start af pumpen
- Ensure the pump is properly primed (see Section 3.3).
- Connect the pump to the power supply. The pump will perform a self-check.
- The Flow-Measurement System (FMS) display will show the current operating status.
- Open a water tap in your system. The pump will automatically start to deliver water.

Figure 2: The control panel of the AL-KO HW 6000 FMS Premium, highlighting the FMS display and mode selection buttons.
4.2 Eco-tilstand
To save energy, switch the pump to Eco mode. This mode can reduce energy consumption by approximately 15% compared to normal operation. Refer to the pump's display and controls for activating Eco mode.
4.3 Dry-Run Protection
The integrated dry-run protection system automatically shuts off the pump if no water is detected in the suction line, preventing damage. If the pump stops due to dry-run protection, check your water source and suction line for issues before restarting.
5. Vedligeholdelse
Regular maintenance ensures the long-term performance and reliability of your pump.
5.1 Rengøring af forfilteret
The pump is equipped with a large, easy-to-clean pre-filter that protects the pump's interior from dirt and debris. Regularly check and clean the filter, especially if you notice a decrease in pump performance.
- Afbryd pumpen fra strømforsyningen.
- Close any valves on the suction and pressure lines.
- Use the provided filter wrench to carefully open the filter housing.
- Remove the filter element and rinse it thoroughly under clean running water.
- Inspect the filter element for damage and replace if necessary.
- Reinsert the clean filter element and securely close the filter housing using the wrench.
- Reconnect power and prime the pump if necessary before restarting.

Figure 3: Using the filter wrench to access and clean the pre-filter.
5.2 Vinterisering
If the pump is exposed to freezing temperatures, it must be drained completely to prevent frost damage. Disconnect all water lines and open the drain plug to allow all water to escape. Store the pump in a frost-free location.
6. Fejlfinding
This section provides solutions to common issues you might encounter with your AL-KO HW 6000 FMS Premium pump.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Pump does not start or deliver water. | No power supply; pump not primed; air in suction line; dry-run protection activated; clogged filter. | Check power connection; prime the pump; check suction line for leaks; check water source; clean pre-filter. |
| Reduced water flow or pressure. | Clogged pre-filter; air in suction line; low water level in source; partially closed valves. | Clean pre-filter; check suction line for leaks; ensure adequate water supply; open all valves fully. |
| Pump runs continuously or cycles frequently. | Leak in pressure system; check valve faulty; insufficient air in pressure tank. | Inspect all connections for leaks; check/replace check valve; ensure proper air charge in the pressure tank (refer to specific instructions for pressure tank maintenance). |
| Usædvanlig støj under drift. | Air in pump/lines; foreign object in pump; motor bearing issue. | Bleed air from the system; disconnect power and inspect pump impeller for obstructions (if safe to do so); if noise persists, contact service. |
If you are unable to resolve the issue using the troubleshooting guide, please contact AL-KO customer support or a qualified service technician.
7. Tekniske specifikationer
| Feature | Specifikation |
|---|---|
| Model | HW 6000 FMS Premium |
| Varenummer | 112852 |
| Fabrikant | AL-KO |
| Motorkraft | 1400 W |
| Maks. Strømningshastighed | 6000 liter i timen |
| Maks. Leveringshoved | 60 meter |
| Maks. Sugehøjde | 8 Meters (typical for self-priming pumps) |
| Pressure Tank Volume | 20 Liters (Stainless Steel) |
| Voltage | 230.01 volt |
| Støjniveau | 73 dB |
| Dimensioner (L x B x H) | 51.6 x 28.4 x 64.7 cm |
| Vægt | 20 kg |
| Materiale | Rustfrit stål |
| Inkluderede komponenter | Instruction manual, corner connection, filter wrench |
8. Garanti og support
AL-KO provides a manufacturer's warranty for this product. Please refer to the warranty card included with your purchase or visit the official AL-KO webwebstedet for detaljerede garantivilkår og -betingelser, der er specifikke for din region.
For technical assistance, spare parts, or service inquiries, please contact AL-KO customer support:
- AL-KO Officiel Webwebsted: www.al-ko.com (Se lokale kontaktoplysninger)
- Kundeservice: Refer to your purchase documentation or the AL-KO webwebsted for regionale kontaktnumre og e-mailadresser.
When contacting support, please have your model number (HW 6000 FMS Premium) and part number (112852) ready.





