Intermatic IW700K

Intermatic IW700K Heavy-Duty Mechanical In-Wall Timer

Instruktionsmanual

Brand: Intermatic | Model: IW700K

Produkt overview

The Intermatic IW700K is a robust mechanical in-wall timer engineered to replace a standard wall switch, offering automated control for a variety of electrical loads. This includes indoor and outdoor lighting, fans, pumps, and office equipment. Its design incorporates 72 captive trippers, facilitating up to 36 ON/OFF events within a 24-hour cycle, with precise 20-minute switching intervals. The unit also features a convenient 3-position override switch (ON/AUTO/OFF) for flexible control. It is suitable for single-pole applications and requires a neutral wire for proper operation. A wall plate is included for a complete installation.

Nøglefunktioner

  • 72 Trippers for Maximum Control: Provides 36 ON/OFF events per 24-hour period, allowing precise control over your electrical devices. The 72 trippers enable fine-tuned scheduling with 20-minute switching intervals, perfect for managing lighting, appliances, and other equipment efficiently.
  • Captive Trippers: Features captive trippers with 20-minute switching intervals, ensuring reliable and consistent operation. The trippers are built into the timer, eliminating the risk of losing them and ensuring long-term reliability.
  • 3-Way Switch Available: Equipped with a 3-way (SPDT) switch, offering flexible installation options and compatibility with various wiring setups. This allows the timer to be used in different configurations, enhancing its versatility for various applications.
  • 3-Position Override: Includes a 3-position ON/OFF/AUTO override, enabling continuous ON or OFF operation as well as automatic control. This feature provides convenience and flexibility, allowing you to override the timer settings when needed for uninterrupted power.
  • Heavy-Duty Rating & Easy Installation: Boasts a heavy-duty 20 A rating for robust performance, suitable for high-power devices. Designed for easy wiring and installation, the timer includes multiple wall plates to fit different decors and setups. Requires a neutral connection for proper operation, ensuring safety and reliability in your electrical system.

Opsætning og installation

The IW700K timer is designed for straightforward installation, replacing a standard wall switch. It is crucial to ensure a neutral wire is available in your electrical box for the timer's clock motor to operate correctly. If you are unsure about your home's wiring, it is highly recommended to consult a qualified electrician or Intermatic Technical Support for assistance.

Kabelføringview:

The timer comes with color-coded lead wires for connection:

  • Hot: Black wire
  • Switched: Red wire
  • Neutral: White wire

For detailed, step-by-step installation instructions, including wiring diagrams and safety precautions, please refer to the official Installation Manual (PDF) provided by Intermatic. This document contains critical information for safe and correct setup.

Side view of the Intermatic IW700K timer showing the internal components and wiring.

Billede: Side view of the IW700K timer, illustrating the wiring connections (black, red, white) and the internal mechanism. This view helps in understanding the physical layout for installation.

Dimensions of the Intermatic IW700K in-wall timer.

Image: Diagram showing the dimensions of the Intermatic IW700K timer, indicating its depth and width for proper fitting into a standard electrical box.

Betjeningsvejledning

The IW700K timer allows for precise scheduling of electrical devices with its mechanical dial and trippers.

Indstilling af timeren

  1. Indstil aktuel tid: Rotate the outer dial clockwise until the current time aligns with the small arrow indicator on the timer face.
  2. Program ON/OFF Events: The dial has 72 captive trippers around its circumference, each representing a 20-minute interval. To set an ON event, push the tripper(s) corresponding to the desired ON time towards the center of the dial. To set an OFF event, leave the tripper(s) at the desired OFF time in their outward position. The timer will activate or deactivate the connected device as the dial rotates past these set trippers.

Using the Override Switch

The timer features a 3-position slide switch located below the dial, providing manual control over the connected load:

  • OFF: Slides the switch to the 'OFF' position to keep the connected device continuously off, overriding any programmed ON events.
  • PÅ: Slides the switch to the 'ON' position to keep the connected device continuously on, overriding any programmed OFF events.
  • BIL: Slides the switch to the 'AUTO' position for the timer to follow the programmed ON/OFF schedule set by the trippers.
Front view of the Intermatic IW700K mechanical in-wall timer with the dial and override switch clearly visible.

Billede: Forside view of the IW700K timer, showing the 24-hour dial with its captive trippers and the three-position (OFF/ON/AUTO) override switch at the bottom. This is the primary interface for setting and controlling the timer.

Opretholdelse

The Intermatic IW700K mechanical timer is designed for durability and requires minimal maintenance.

Pleje og rengøring

  • To clean the timer's surface, gently wipe it with a soft, dry cloth.
  • Avoid using abrasive cleaners, solvents, or harsh chemicals, as these can damage the plastic finish or internal components.
  • Ensure the timer is disconnected from power before any cleaning beyond surface wiping.

No user-serviceable parts are inside the timer mechanism. Do not attempt to disassemble the unit.

Fejlfinding

If you encounter issues with your Intermatic IW700K timer, please review følgende almindelige problemer og deres mulige løsninger:

  • Timer Dial Not Moving:
    • Verify that the timer is receiving continuous power.
    • Confirm that a neutral wire is properly connected. The clock motor requires a neutral connection to operate.
    • Ensure the override switch is not stuck in an intermediate position.
  • Programmed Events Not Activating/Deactivating:
    • Check that the override switch is set to the 'AUTO' position.
    • Ensure the ON/OFF trippers are correctly pushed in or left out according to your desired schedule.
    • Verify the current time is accurately set on the dial.
  • Device Stays ON/OFF Continuously:
    • Confirm the override switch is in the 'AUTO' position if you desire programmed operation. If it's in 'ON' or 'OFF', it will override the schedule.
  • Humming Noise from Timer:
    • A slight hum is normal for mechanical timers due to the synchronous motor. If the hum is excessively loud or accompanied by other issues, contact support.

If these steps do not resolve the issue, or if you suspect a wiring problem, please contact Intermatic Technical Support or a qualified electrician.

Specifikationer

AttributVærdi
ModelnummerIW700K
MærkeIntermatic
FarveHvid
MaterialePlast
Produktmål (D x B x H)3" D x 3" B x 4" H
Varens vægt4.8 ounce
Resistiv vurdering20A, 120 VAC
Motorvurdering1 HP, 120 VAC
Number of ON/OFF Events36 per 24-hour period
Switch Type3-way (SPDT)
MonteringstypeVægmontering
UPC078275143456
CertificeringerCSA certified, UL listed

Garanti og support

Garantioplysninger

This Intermatic product comes with a manufacturer's warranty. For specific details regarding the warranty period, coverage, and terms, please refer to the documentation included with your product or visit the official Intermatic webwebsted.

Kundesupport

For technical assistance, troubleshooting, or any questions regarding the Intermatic IW700K timer, please contact Intermatic Technical Support. You can also find additional resources, including the full installation manual, on the official Intermatic webwebsted.

Officiel installationsmanual (PDF): Download her

Relaterede dokumenter - IW700K

Preview Intermatic TIME-ALL HB114 Kraftig 240V Timer - Opsætnings- og betjeningsvejledning
Omfattende guide til Intermatic TIME-ALL HB114 Heavy Duty 240V plug-in timeren, der dækker opsætning, programmering, manuel betjening, specifikationer og sikkerhedsadvarsler.
Preview Intermatic TN311 Timer Brugermanual og Garanti
Brugervejledning og information om et års begrænset garanti til Intermatic TN311 timeren til kraftig jordet stikkontakt. Lær, hvordan du indstiller programmet, klokkeslættet og den automatiske overstyring.
Preview Intermatic SS7-seriens programmerbare timer: Installations- og betjeningsvejledning
Omfattende vejledning til installation og betjening af Intermatic SS7-seriens elektroniske timer, inklusive funktioner, programmering, ledningsføring, fejlfinding og garantioplysninger.
Preview Installations- og programmeringsvejledning til Intermatic EJ341C/EJ343C belysningstimer
Detaljerede instruktioner til installation og programmering af Intermatic EJ341C (enkeltpolet) og EJ343C (trevejs) belysningstimerkontakter. Dækker opsætning, styring, programmeringsmetoder, fejlfinding og specifikationer.
Preview Intermatic EI500 Series Timer Settings and Programming Guide
Detailed instructions for setting the clock, programming events, clearing events, operating modes (Auto, Random, Manual), and overriding settings for the Intermatic EI500 Series timer.
Preview ET724 Elektronisk vægindbygningstimer: Brugsanvisning og programmeringsvejledning
Detaljeret betjeningsvejledning til ET724 elektronisk vægindbygningstimer, der dækker installation, opstartssekvens, tidsindstilling, programmering af tænd/sluk-hændelser, blokprogrammering,viewprogrammer, manuel overstyring, hukommelsesbackup og deaktiveringsfunktion. Inkluderer elektriske klassificeringer og tips til fejlfinding.