VOLTCRAFT VC-55 LCD

VOLTCRAFT VC-55 LCD 2-polet voluminiumtage Testerens instruktionsmanual

Brand: VOLTCRAFT | Model: VC-55 LCD

1. Introduktion

This manual provides essential information for the safe and effective use of your VOLTCRAFT VC-55 LCD 2-Pole Voltage Tester. This device is designed for reliable voltage testing, continuity checks, unipolar phase testing, and rotating field testing. It features both an LCD and LED display for clear readings and is built to meet EN 61243-3 and VDE0682 standards, ensuring high safety and performance.

2. Sikkerhedsoplysninger

WARNING: Electrical testing can be hazardous. Always follow safety precautions to prevent injury or damage.

  • Always inspect the tester for damage before use. Do not use if the housing, test leads, or probes are damaged.
  • Sørg for, at enheden er klassificeret til lydstyrkentage and current levels you intend to measure. This tester is rated CAT III 1000 V and CAT IV 600 V.
  • Never touch live conductors with bare hands. Use appropriate personal protective equipment (PPE).
  • Do not use the tester in wet conditions or in explosive atmospheres.
  • Verify the tester's functionality on a known live source before and after each use.
  • If you are unsure about any procedure, consult a qualified electrician.

3. Produktet er slutview

Nøglefunktioner

  • CAT III 1000 V, CAT IV 600 V sikkerhedsklassificering
  • LCD and LED voltage display (12 V to 690 V)
  • Continuity test with acoustic and visual indication
  • Unipolar phase test
  • Rotating field test
  • Integrated measurement point illumination (flashlight)
VOLTCRAFT VC-55 LCD 2-polet voluminiumtage tester

Figure 1: The VOLTCRAFT VC-55 LCD 2-Pole Voltage Tester, showing its main body, test leads, and display.

4. Opsætning

4.1 Batteriinstallation

The VC-55 LCD requires 2 AAA batteries (included) for operation. To install or replace batteries:

  1. Find batteridækslet på bagsiden af ​​enheden.
  2. Use a suitable tool (e.g., a small screwdriver) to open the cover.
  3. Isæt de 2 AAA-batterier, og sørg for at polerne vender korrekt (+/-).
  4. Luk dækslet til batterirummet forsvarligt.

4.2 Probe Preparation

The test probes come with protective caps and interchangeable tips. For most applications, the standard tips are suitable. For testing in sockets with child protection, screw-on round tips are provided.

Close-up of VOLTCRAFT VC-55 LCD probes and interchangeable tips

Figur 2: Nærbillede view of the test probes and the included interchangeable tips for various testing scenarios.

5. Betjeningsvejledning

5.1 bindtage-måling (AC/DC)

At måle voltage:

  1. Connect both test probes to the circuit or component you wish to measure.
  2. Voltage value will be displayed on the LCD screen.
  3. Corresponding LEDs will illuminate to indicate the voltage range (12V, 24V, 50V, 120V, 230V, 400V, 690V).
  4. The device automatically detects AC or DC voltage.
VOLTCRAFT VC-55 LCD in use measuring voltage i et elektrisk panel

Figure 3: The VC-55 LCD tester actively measuring voltage within an electrical control panel, displaying readings on its screen.

5.2 Kontinuitetstest

Sådan udføres en kontinuitetstest:

  1. Ensure the circuit is de-energized before testing for continuity.
  2. Touch the two test probes to the ends of the circuit or component you want to test.
  3. If continuity exists (low resistance), an acoustic signal will sound, and a dedicated LED will illuminate.

5.3 Unipolar Phase Test

To test for phase (live wire) in AC circuits:

  1. Hold the main body of the tester firmly.
  2. Touch only one test probe to the conductor you suspect is live.
  3. If the conductor is live, the phase indicator (usually an 'R' or similar symbol) on the display will light up.

5.4 Rotating Field Test

To determine the phase sequence in three-phase systems:

  1. Connect the test probes to two phases of the three-phase system.
  2. The tester will indicate the direction of the rotating field (e.g., 'L' for left, 'R' for right, or arrows).
VOLTCRAFT VC-55 LCD in use testing a wall socket

Figure 4: The VC-55 LCD tester being used to safely check the voltage and presence of live wires in a standard wall socket.

6. Vedligeholdelse

  • Rensning: Clean the device regularly with a dry, lint-free cloth. Do not use abrasive cleaners or solvents.
  • Opbevaring: Store the tester in a dry, cool place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
  • Udskiftning af batteri: Udskift batterierne, når indikatoren for lavt batteriniveau vises på LCD-skærmen.

7. Fejlfinding

  • Intet display/Ingen strøm: Kontroller batteriinstallationen, og sørg for, at batterierne ikke er afladede. Udskift om nødvendigt.
  • Upræcise læsninger: Ensure probes are making good contact with the test points. Verify the tester on a known voltage kilde.
  • Ingen kontinuitetsindikation: Ensure the circuit is de-energized. Check for open circuits or high resistance.
  • Tester Not Responding: Remove batteries, wait a few seconds, and reinsert them. If the issue persists, contact customer support.

8. Specifikationer

FeatureSpecifikation
MærkeVOLTCRAFT
ModelnummerVC-55 LCD
Måletype2-Pole Voltage tester
SikkerhedsvurderingCAT III 1000V, CAT IV 600V
Voltage DisplayLCD and LED (12 V to 690 V)
Kompatible specifikationerEN 61243-3/VDE0682
StrømkildeBattery Powered (2 AAA - included)
Min. Driftsvoltage12 volt
Max. Rated Temperature71 grader Celsius
FarveSort og hvid
Emnedimensioner30.7 x 19 x 4.2 cm
Varens vægt9.07 gram
Tilgængelighed af reservedele1 år

9. Garanti og support

This VOLTCRAFT product is designed for durability and reliability. For information regarding warranty coverage, spare parts availability, or technical support, please refer to the documentation included with your purchase or visit the official VOLTCRAFT website. For specific inquiries, you may also contact the seller directly.

Relaterede dokumenter - VC-55 LCD

Preview VOLTCRAFT VC292 Digitalmultimeter Bedienungsanleitung und Technische Daten
Umfassende Bedienungsanleitung für das VOLTCRAFT VC292 Digitalmultimeter og den Stromzangenwandler CLA60, inklusive Sicherheitshinweisen, Messanleitungen og tekniske specifikationer.
Preview VOLTCRAFT Digitale Multimetre VC-7060BT & VC-7200BT Brugermanual
Omfattende brugermanual til VOLTCRAFT VC-7060BT og VC-7200BT digitale multimetre, der dækker sikkerhed, betjening, funktioner, målevejledninger, fejlfinding og tekniske specifikationer.
Preview VOLTCRAFT VC-7060BT & VC-7200BT Digitalt Multimeter Lynguide
Omfattende hurtigguide til VOLTCRAFT VC-7060BT og VC-7200BT digitale multimetre. Lær om sikkerhed, betjening, målinger og fejlfinding.
Preview VOLTCRAFT VC891 Multimetro Digitale: Istruzioni per l'uso e Specifiche Tecniche
Manuale d'uso completo per il multimetro digitale VOLTCRAFT VC891. Include istruzioni dettagliate su utilizzo, misurazioni, funzioni aggiuntive, manutenzione e specifiche tecniche. Ideale per professionisti e hobbisti.
Preview VOLTCRAFT VC-BT300PRO OBDII + Batteriester Bedienungsanleitung
Omfattende Bedienungsanleitung for VOLTCRAFT VC-BT300PRO, en Diagnoseworkzeug for OBD-II og batteritests. Enthält Funktionen, Sicherheitshinweise und technische Daten.
Preview VOLTCRAFT MT-52 5-i-1 digitalt multimeter brugermanual
Dette dokument indeholder omfattende betjeningsvejledninger, sikkerhedsretningslinjer og tekniske specifikationer for VOLTCRAFT MT-52 5-i-1 digitalt multimeter. Lær, hvordan du måler vol.tage, strøm, modstand, temperatur, fugtighed, lys og lydniveauer.