An image showing the Field Controls MG-1 Gas Draft Control Regulator, a circular metal device with a clear cover and a chain for adjustment.
This manual provides essential information for the safe and effective use of your Field Controls 6-inch MG-1 Gas Draft Control/Regulator. This device is designed to provide precise and accurate control of drafts in gas-fired heating systems, particularly in applications where higher draft levels are required than those managed by standard draft diverters.
Sikkerhed først: Installation of gas appliances and their components should only be performed by qualified and licensed professionals. Improper installation can lead to serious injury, property damage, or death. Always consult local codes and regulations.
The Field Controls MG-1 is designed for installation on the flue pipe of a gas appliance. Key dimensions for this model include:
Ensure the installation location provides adequate clearance for the regulator's operation and future maintenance. The device should be securely mounted to prevent movement or vibration.
The MG-1 Gas Draft Control/Regulator automatically adjusts to maintain a consistent draft in the flue, optimizing combustion efficiency and safety. It operates by opening or closing a damper to regulate the flow of combustion gases. This precise control is crucial for gas appliances that require specific draft conditions for optimal performance and to prevent issues such as incomplete combustion or excessive heat loss.
The regulator's design allows for fine-tuning of the draft, ensuring that the appliance operates within its specified parameters, even when external conditions (like wind or atmospheric pressure) fluctuate.
Regular inspection and maintenance are essential to ensure the continued safe and efficient operation of your Field Controls MG-1 Gas Draft Control/Regulator. It is recommended that a qualified technician perform annual inspections as part of your heating system's routine maintenance.
Do not attempt to lubricate or modify the internal components of the regulator unless specifically instructed by the manufacturer.
If you suspect an issue with your gas draft control, it is crucial to contact a qualified HVAC technician immediately. Attempting to diagnose or repair gas appliance components without proper training and tools can be dangerous.
Common indicators of a potential issue might include:
A technician can assess the draft conditions, inspect the regulator, and perform any necessary adjustments or replacements.
| Specifikation | Detalje |
|---|---|
| Fabrikant | Feltkontrol |
| Varenummer | 02724001 |
| Varemodelnummer | 6MG1 |
| Varens vægt | 2.2 pund |
| Produktdimensioner | 6 x 3 x 6 tommer |
| Inkluderede komponenter | Gas Draft Control |
| ASIN | B00ICS1GUA |
| Dato først tilgængelig | 10. februar 2014 |
Specific warranty details for the Field Controls 6-inch MG-1 Gas Draft Control/Regulator are not provided in this document. Please refer to the product packaging or the official Field Controls webwebstedet for de seneste garantioplysninger.
For technical assistance, installation questions, or service inquiries, please contact Field Controls directly or consult a qualified HVAC professional.
You can find more information about Field Controls products and support on their official website or by visiting their Amazon Brand Store.
![]() |
Feltstyringer CK-61, 62, 63 Ledningsdiagrammer til oliefyrede systemer Detaljerede ledningsdiagrammer for Field Controls CK-61, 62 og 63 oliefyrede enkeltstående systemer, inklusive tilslutninger til effektventilator, trækdæmper, primærstyring og tændingstransformator. |
![]() |
Feltstyringer Power Venter PVG-100, PVG-300, PVG-600 Installationsmanual This installation manual provides detailed instructions for the Field Controls Power Venter models PVG-100, PVG-300, and PVG-600. It covers unit specifications, sizing calculations, safety precautions, installation procedures, wiring diagrams, system checks, maintenance, and troubleshooting for HVAC applications. |
![]() |
Feltstyring SWG/CV Power Venter: Installation, dimensionering og specifikationer Omfattende guide til feltstyrings-SWG- og ComboVent (CV)-ventilatorer, der dækker produktfunktioner, dimensionering, installation, systemplanlægning, afstande, kontrolsæt, systemopsætning og vedligeholdelse. Indeholder detaljerede specifikationer og råd om fejlfinding. |
![]() |
Flue Sentinel Millivolt Pejs DampInstallationsmanual | Feltkontroller Installationsvejledning til Flue Sentinel Millivolt Pejs Damper (FSM-serien) fra Field Controls. Dækker specifikationer, dimensioner, installationsprocedurer, ledningsdiagrammer, betjeningsrækkefølge, fejlfinding og vedligeholdelse af gaspejse. |
![]() |
Field Controls S2000 & S2020 luftfugter: Installations- og brugermanual Comprehensive installation instructions and owner's manual for Field Controls S2000 (120VAC) and S2020 (240VAC) electronic steam power humidifiers. Learn how to install, operate, and maintain your unit for optimal performance in forced air systems. |
![]() |
Brugermanual til Trio Plus luftrenser | Feltkontroller Omfattende brugermanual til Field Controls Trio Plus luftrenser, der dækker sikkerhed, betjening, vedligeholdelse, filterudskiftning, fejlfinding og specifikationer. |