1. Introduktion
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Astralpool Digital Display Anti-Freeze Control Box, model FD-45600. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.
The Astralpool Anti-Freeze Control Box is designed to protect your swimming pool's hydraulic installation from freezing temperatures by automatically activating the filtration pump when the water temperature drops below a set threshold.
2. Sikkerhedsoplysninger
Vigtige sikkerhedsinstruktioner:
- Installation must be performed by a qualified professional electrician in accordance with local electrical codes and regulations.
- Ensure the power supply is disconnected before performing any installation, maintenance, or repair work.
- The control box is rated IP54, providing protection against dust and splashing water. However, it should not be submerged or exposed to direct high-pressure water jets.
- Betjen ikke enheden, hvis en del er beskadiget.
- Keep children away from the control box and pool equipment.
3. Produktfunktioner
The Astralpool Digital Display Anti-Freeze Control Box offers the following key features:
- IP54 Enclosure: Yder beskyttelse mod støv og stænkvand.
- NTC-sonde: High-precision temperature sensor for accurate readings.
- Digital skærm: Clear digital readout for temperature and settings.
- Universal kompatibilitet: Adaptable to existing pool installations.
- Complete Anti-Freeze Kit: Simplifies pool winterization and spring opening.
- Automatic Filtration Activation: Protects against freezing by circulating pool water.
4. Pakkens indhold
Kontroller, at alle komponenter er til stede og ubeskadigede ved udpakning:
- Astralpool Digital Display Anti-Freeze Control Box (FD-45600)
- NTC temperatursonde
- Instruktionsmanual (dette dokument)

Figur 1: Astralpool Digital Display Anti-Freeze Control Box (FD-45600) with its NTC temperature probe. The control box features a digital display and control buttons, while the probe is connected via a cable.
5. Opsætning og installation
Professionel installation påkrævet: This electrical control box must be installed by a qualified professional to ensure safety and compliance with electrical standards.
5.1 Mounting the Control Box
- Choose a suitable location for the control box, protected from direct sunlight and excessive moisture, yet accessible for operation and maintenance.
- Ensure the mounting surface is stable and capable of supporting the weight of the unit.
- Mount the control box securely using appropriate fasteners.
5.2 Elektriske forbindelser
All electrical connections must be made with the main power supply disconnected.
- Connect the main power supply to the designated terminals within the control box.
- Connect the pool filtration pump to the output terminals of the control box.
- Connect the NTC temperature probe to its dedicated input terminals.
- Sørg for, at alle forbindelser er tætte og korrekt isolerede.
5.3 NTC Probe Placement
The NTC probe measures the water temperature. Its correct placement is crucial for accurate readings and effective anti-freeze protection.
- Install the NTC probe in the pool's hydraulic circuit, ideally after the filter and before any heating elements, in a location that accurately reflects the pool water temperature.
- Ensure the probe is fully immersed in the water flow.
6. Betjening
6.1 Tænd
Once installation is complete and verified by a professional, restore power to the control box. The digital display will illuminate, showing the current water temperature.
6.2 Setting the Anti-Freeze Threshold
The anti-freeze threshold is the temperature at which the control box will activate the filtration pump to prevent freezing.
- Press and hold the "SET" button for more than 2 seconds.
- The display will show the current set point temperature (e.g., "C" followed by the temperature in °C).
- Use the "Up" (▲) and "Down" (▼) buttons to adjust the desired anti-freeze temperature. A common setting is between 1°C and 4°C.
- To confirm and save the new set point, press the "SET" button again, or wait for 10 seconds for the setting to automatically save and return to normal operation.
6.3 Automatisk drift
When the water temperature measured by the NTC probe falls below the set anti-freeze threshold, the control box will automatically activate the pool filtration pump. The pump will run until the water temperature rises above the threshold, preventing ice formation in the pipes and equipment.
This system simplifies active winterization, allowing the pool to remain filled without the need to significantly lower the water level.
7. Vedligeholdelse
Regular maintenance ensures the reliable operation and longevity of your anti-freeze control box.
- Årlig inspektion: Have a qualified professional inspect the control box and all electrical connections annually, especially before the winter season.
- Renhed: Keep the exterior of the control box clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Probe Check: Periodically check the NTC temperature probe for any signs of damage or corrosion. Ensure it is securely in place and fully immersed in water.
- Funktionstest: Before winter, test the anti-freeze function by temporarily lowering the set point or using a cold object near the probe (if safely accessible) to verify the pump activates.
8. Fejlfinding
This section provides solutions to common issues. For problems not listed here, or if issues persist, contact a qualified service technician.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Skærmen er slukket / Ingen strøm | Ingen strømforsyning; Sprunget sikring; Løs forbindelse | Check main power supply; Inspect fuses; Verify electrical connections (by a professional). |
| Pump does not activate when temperature is low | Incorrect set point; Faulty NTC probe; Pump issue; Wiring error | Verify anti-freeze set point; Check NTC probe connection/function; Inspect pump operation; Have wiring checked by a professional. |
| Unøjagtig temperaturaflæsning | NTC probe improperly placed; Faulty NTC probe | Ensure probe is fully immersed and in proper location; Replace NTC probe if faulty. |
| Pumpen kører kontinuerligt | Set point too high; Faulty NTC probe; Control box malfunction | Adjust set point to a lower, appropriate temperature; Check NTC probe; Contact service technician. |
9. Specifikationer
- Model: FD-45600
- Mærke: Astralpool
- Beskyttelse af kabinet: IP54
- Temperatursensor: NTC sonde
- Vise: Digital
- Kompatibilitet: Adaptable to existing installations
- Fabrikant: ASTRAL POOL
10. Garanti og support
Dette produkt leveres med en 1 års garanti from the date of purchase, covering manufacturing defects. The warranty does not cover damage resulting from improper installation, misuse, neglect, or unauthorized repairs.
For technical support, warranty claims, or spare parts inquiries, please contact your authorized Astralpool dealer or the manufacturer directly. Please have your model number (FD-45600) and proof of purchase available when contacting support.
Availability of spare parts information is currently unavailable.