1. Introduktion

This manual provides essential information for the safe and proper installation, operation, and maintenance of the Armstrong R47582-001 OEM Replacement Furnace Control Board. This component is designed to replace original equipment manufacturer (OEM) control boards in compatible Armstrong furnace models, ensuring reliable performance of your heating system.

Please read this manual thoroughly before attempting any installation or service. Retain this document for future reference.

2. Sikkerhedsoplysninger

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

  • Always disconnect electrical power to the furnace at the main service panel before installing or servicing the control board. Failure to do so can result in electrical shock, personal injury, or death.
  • Sørg for, at alle ledningsforbindelser er sikre og overholder lokale og nationale elektriske forskrifter.
  • Wear appropriate personal protective equipment (PPE), including safety glasses and gloves, during installation and service.
  • Omgå ikke nogen sikkerhedsanordninger.
  • Kontroller, at udskiftningskortet er kompatibelt med din specifikke ovnmodel, før du installerer det.

3. Produktet er slutview

The Armstrong R47582-001 is an OEM replacement furnace control board responsible for managing the various functions of a furnace, including ignition, fan operation, and safety monitoring. It integrates with other furnace components to ensure efficient and safe heating.

Armstrong R47582-001 OEM Replacement Furnace Control Board

Figur 1: Armstrong R47582-001 OEM Replacement Furnace Control Board. This image displays the top-down view of the circuit board, showing various relays, resistors, capacitors, and terminal blocks for electrical connections. Key components include multiple black relays, a yellow fuse, and screw terminals labeled for common furnace wiring (R, W, Y, G, C).

4. Opsætning og installation

Installation of this control board should only be performed by a qualified HVAC technician. The following steps are general guidelines and may vary based on your specific furnace model.

  1. Strømafbrydelse: Turn off all electrical power to the furnace at the main circuit breaker or fuse box. Verify power is off using a voltage tester.
  2. Adgangskontroltavle: Åbn ovnens adgangspanel for at finde det eksisterende kontrolkort.
  3. Dokumentledningsføring: Before disconnecting any wires, take clear photographs of all wiring connections to the old board. Label each wire with its corresponding terminal designation (e.g., R, W, Y, G, C, fan, limit, igniter, etc.).
  4. Frakobl ledninger: Frakobl forsigtigt alle ledninger fra det gamle styrekort.
  5. Fjern gammelt bræt: Unmount the old control board from its housing. Note its orientation.
  6. Installer nyt kort: Mount the new Armstrong R47582-001 control board in the same location and orientation as the old board.
  7. Tilslut ledningerne igen: Using your photographs and labels, reconnect all wires to their correct terminals on the new board. Ensure all connections are tight and secure.
  8. Luk adgangspanel: Luk adgangspanelet til ovnen forsvarligt.
  9. Gendan strøm: Restore electrical power to the furnace at the main circuit breaker.
  10. Test drift: Initiate a heating cycle to verify proper furnace operation. Observe for any unusual noises, smells, or error codes.

5. Betjeningsvejledning

The Armstrong R47582-001 control board operates automatically as part of your furnace system. Once correctly installed, it will manage the furnace's heating cycles based on thermostat demands and internal safety protocols. There are no direct user operating controls on the board itself.

Ensure your thermostat is set to the desired temperature and mode (Heat/Cool/Auto) for the furnace to respond appropriately. The control board will then initiate the ignition sequence, monitor flame presence, control the blower motor, and manage other system functions.

6. Vedligeholdelse

The control board itself requires no routine maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and efficient operation. This includes:

  • Filterudskiftning: Regularly replace or clean the furnace air filter as recommended by your furnace manufacturer. A dirty filter can restrict airflow and strain the system.
  • Årlige inspektioner: Schedule annual professional inspections and tune-ups for your furnace. A qualified technician can identify potential issues before they lead to component failure.
  • Hold området ryddet: Ensure the area around the furnace is free from obstructions and combustible materials.

7. Fejlfinding

If your furnace is not operating correctly after installing the new control board, consider the following basic troubleshooting steps. For complex issues, contact a qualified HVAC technician.

SymptomMulig årsagHandling
Ovnen starter ikkeNo power, thermostat issue, loose wiring, blown fuse on board.Check circuit breaker. Verify thermostat settings. Inspect all wiring connections. Check the fuse on the control board (refer to Figure 1 for fuse location).
Blower fan not runningIncorrect wiring, fan motor issue, control board fault.Ensure fan wires are correctly connected. If the fan runs in manual mode but not auto, the board might be faulty or miswired.
Ovnen tænder og slukker hurtigt (korte cyklusser)Restricted airflow, dirty filter, faulty limit switch, thermostat issue.Check and replace air filter. Ensure vents are open. Consult a technician for limit switch diagnosis.
Ingen varmeIgnition failure, gas supply issue, flame sensor dirty, control board fault.Verify gas supply. Clean flame sensor. If the board has diagnostic lights, consult your furnace manual for error codes.

Many control boards include diagnostic LED lights that flash specific codes to indicate system status or errors. Refer to your furnace's original manual for a list of these codes and their meanings.

8. Specifikationer

  • Modelnummer: R47582-001 (also CECOMINOD048151)
  • Fabrikant: Armstrong (OEM Replacement)
  • Produktdimensioner: Approximately 6 x 6 x 6 inches (as packaged)
  • Varens vægt: Approximately 0.01 ounces (board only)
  • Form: Rektangulær
  • Varepakkemængde: 1
  • Batterier påkrævet: Ingen

9. Garanti og support

As an OEM replacement part, the warranty for the Armstrong R47582-001 control board typically aligns with the seller's policy or the original equipment manufacturer's terms for replacement parts. Please refer to your purchase documentation or contact the seller directly for specific warranty details.

For technical support or assistance with installation and troubleshooting beyond the scope of this manual, it is recommended to contact a certified HVAC professional.

Relaterede dokumenter - R47582-001

Preview Armstrong HVAC Tekniske Tips og Servicebulletiner
Samling af tekniske tips og servicebulletiner fra Armstrong Air Conditioning, der dækker forbedringer af tændingsstyring, kontinuerlig blæserdrift, kompressordetaljer, filterdimensionering, ledningsføring, tagkanter og fejlfinding for PGE-, PHP-, PCE- og SHP HVAC-enheder.
Preview L83BR1D84/95E16 reservedelsliste og komponentguide
Dette dokument indeholder en omfattende liste over dele til L83BR1D84/95E16-modellen med detaljerede oplysninger om komponentnavne, delnumre og beskrivelser, der hjælper med identifikation og udskiftning.
Preview Armstrong GFCI Receptacle Installation and Testing Guide
A comprehensive guide for installing and testing Armstrong GFCI receptacles, including wiring instructions, troubleshooting tips, and warranty information.
Preview Montering af Armstrong-lofter overviewEn trin-for-trin guide
Lær hvordan du installerer et Armstrong-loft med denne korte vejledningviewDækker væglister, bjælker, tværprofiler og montering af loftspaneler til boligbrug. Har QuickHang™-beslag.
Preview Monterings- og driftsvejledning til Armstrong E.2-seriens højeffektive cirkulator
Omfattende installations- og betjeningsvejledning til Armstrong E.2-seriens højeffektive cirkulationspumpe, der dækker driftsgrænser, elektrisk ledningsføring, opstartsprocedurer, vedligeholdelse, udskiftning af pumpe og udskiftning af mekaniske tætninger.
Preview WoodWorks® monteringsvejledning til skjulte lister | Armstrong
Omfattende installationsvejledning til Armstrongs WoodWorks® skjulte loftlister. Lær, hvordan du korrekt installerer denne arkitektoniske loftlister til WoodWorks® skjulte og lineære finerede paneler.