Schneider Electric HOM125

Brugermanual til Schneider Electric Square D HOM125 Plug-in-afbryder

Model: HOM125 | Mærke: Schneider Electric

1. Sikkerhedsoplysninger

ADVARSEL: Risk of electric shock, explosion, or arc flash. Installation and maintenance must be performed by qualified personnel only. Read these instructions carefully and look at the equipment to become familiar with the device before trying to install, operate, service, or maintain it.

  • Always turn off power at the main disconnect before working on electrical equipment.
  • Brug en voltagen tester for at bekræfte, at strømmen er slukket, før du rører ved nogen ledninger.
  • Brug passende personlige værnemidler (PPE).
  • Følg alle lokale og nationale elektriske regler.
  • This circuit breaker is designed for use in Square D Homeline load centers only.

2. Produktet er slutview

The Schneider Electric Square D HOM125 is a 25 Amp, single-pole, thermal-magnetic plug-in circuit breaker designed for use in Homeline load centers. It provides overcurrent protection for electrical circuits, safeguarding wiring and equipment from damage due to overloads and short circuits. This breaker has a 10 kA interrupting rating and is rated for 120/240 VAC at 50/60 Hz.

Nøglefunktioner:

  • Type: Thermal-Magnetic Branch Circuit Breaker
  • Nuværende vurdering: 25 Amperes
  • polakker: 1-Pole
  • Voltage Bedømmelse: 120 / 240 VAC
  • Afbrydelse af bedømmelse: 10 kA
  • Montering: Plug-in
  • Terminal type: Skrue Clamp
  • Kompatibilitet: Square D Homeline Load Centers
Square D HOM125 Circuit Breaker, top-down view

Figur 1: Top-down view of the Square D HOM125 circuit breaker, showing the toggle switch and rating labels.

3. Installation

VIGTIG: Installation must be performed by a qualified electrician in accordance with all applicable electrical codes.

  1. Forbered læssecentret:
    • Ensure all power to the load center is OFF at the main disconnect. Verify with a voltage tester.
    • Remove the load center cover.
  2. Connect the Circuit Wire:
    • Strip approximately 1/2 inch (12.7 mm) of insulation from the circuit wire (14 to 8 AWG aluminum/copper, or two 14 to 10 AWG copper wires).
    • Insert the stripped end of the circuit wire into the screw clamp terminal on the breaker.
    • Tighten the terminal screw firmly to the specified torque (refer to load center instructions for exact torque specifications). Ensure the wire is securely fastened and no bare strands are exposed outside the terminal.
    Square D HOM125 Circuit Breaker, rear view viser skrueterminaler

    Figur 2: Bag view of the HOM125 circuit breaker, highlighting the screw clamp terminals for wire connection.

  3. Installer afbryderen:
    • Position the breaker so that the clip on the back engages with the mounting rail in the load center.
    • Align the plug-on connector with the bus bar stab.
    • Firmly press the breaker onto the bus bar until it is fully seated and clicks into place.
    Square D HOM125 Circuit Breaker, side view showing plug-in connector

    Figur 3: Side view of the HOM125 circuit breaker, illustrating the plug-in connection mechanism.

  4. Gendan strøm:
    • Replace the load center cover.
    • Turn the main disconnect power back ON.
    • Switch the newly installed circuit breaker to the "ON" position.

4. Betjening

The HOM125 circuit breaker operates as a protective device for your electrical circuit. It has two primary states: ON and OFF, and a tripped state.

  • ON position: When the toggle handle is in the "ON" position, power is supplied to the connected circuit.
  • OFF position: When the toggle handle is manually moved to the "OFF" position, power to the connected circuit is interrupted.
  • UDLØST position: If an overload or short circuit occurs, the breaker will automatically move to a central, "TRIPPED" position (often indicated by the handle being between ON and OFF, or slightly past OFF). This indicates that the breaker has interrupted the circuit to prevent damage.
Square D HOM125 Circuit Breaker, showing the toggle switch

Figur 4: Nærbillede view of the HOM125 circuit breaker's toggle switch, which indicates the ON, OFF, or TRIPPED status.

Resetting a Tripped Breaker

If the circuit breaker trips, follow these steps:

  1. Identificér årsagen: Unplug or turn off any appliances or devices on the affected circuit that may have caused the overload or short circuit.
  2. Reset the Breaker:
    • First, firmly push the breaker handle completely to the "OFF" position. You may feel a click.
    • Tryk derefter håndtaget fast til "ON"-positionen.
  3. Overvåge: If the breaker trips again immediately, there may be a persistent issue (e.g., a short circuit or a faulty appliance). Do not repeatedly reset the breaker without addressing the underlying problem. Consult a qualified electrician.

5. Vedligeholdelse

The Square D HOM125 circuit breaker is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection is recommended.

  • Visuel inspektion: Annually, or as needed, inspect the breaker for any signs of physical damage, discoloration, or loose connections. Ensure the toggle handle moves freely.
  • Rensning: If necessary, gently clean the exterior of the breaker with a dry, lint-free cloth. Do not use liquids or abrasive cleaners. Ensure power is off before cleaning.
  • Tilslutningskontrol: Periodically, with power off, verify that the wire terminal screws are tight. Loose connections can cause overheating.

If any issues are observed, consult a qualified electrician for assessment and potential replacement.

6. Fejlfinding

Dette afsnit omhandler almindelige problemer, du kan støde på med din afbryder.

ProblemMulig årsagLøsning
Breaker rejser ofte.Overbelastet kredsløb, kortslutning, jordfejl eller defekt apparat.
  • Reduce the load on the circuit by unplugging devices.
  • Undersøg apparater for fejl.
  • If problem persists, consult an electrician to check for short circuits or ground faults.
Afbryderen nulstilles ikke.Vedvarende overbelastning eller kortslutning eller intern afbryderfejl.
  • Ensure all devices on the circuit are unplugged or off.
  • Attempt to reset by pushing fully to OFF, then to ON.
  • If it still won't reset, the breaker may be faulty or there's a severe electrical issue. Consult an electrician.
Breaker is hot to the touch.Overbelastning, løs forbindelse eller intern fejl.
  • Immediately turn off power to the circuit.
  • Consult an electrician to inspect for loose connections or an overloaded circuit.

7. Specifikationer

SpecifikationDetalje
ModelnummerHOM125
MærkeSchneider Electric (Square D)
Nuværende vurdering25 Amps
Antal poler1
Voltage Bedømmelse120/240 VAC at 50/60 Hz (UL/CSA)
Afbrydende vurdering10 kA
Afbryder typeThermal-Magnetic, Standard
MonteringstypePlug-in montering
TerminaltypeSkrue Clamp
Wire Size Compatibility14 to 8 AWG (Aluminum/Copper), (2) 14 to 10 AWG (Copper)
Dimensioner (ca.)1 inch W x 2.98 inch D x 3.13 inch H
GodkendelserUL, CSA

8. Garanti og support

For specific warranty information, please refer to the documentation provided with your Square D Homeline load center or contact Schneider Electric customer support directly. General product support and technical assistance can be obtained through the official Schneider Electric webhjemmeside eller ved at kontakte deres kundeserviceafdeling.

Schneider Electrics kontaktoplysninger:

Relaterede dokumenter - HOM125

Preview Installationsvejledning til Schneider Electric PowerPacT™ L-ramme afbrydersæt til NQ-paneler
Denne instruktionsbulletin fra Schneider Electric indeholder detaljerede trin til installation af NQMB6PPL-sættet, inklusive PowerPacT™ L-Frame hoved- og underafbrydere, på NQ-tavler. Indeholder sættets indhold, værktøj og sikkerhedsforanstaltninger.
Preview Installations- og testvejledning til Schneider Electric QO/QOB dobbeltfunktionsafbryder
Dette dokument indeholder vigtige oplysninger om installation, test og afmontering af Schneider Electric QO og QOB Dual Function (AFCI/GFCI) afbrydere. Det indeholder detaljerede sikkerhedsadvarsler, trinvise instruktioner og fejlfindingsnoter for korrekt drift og vedligeholdelse.
Preview Installationsvejledning til Homeline™ Kombinationsindgangsenheder til afbrydere
Omfattende vejledning til installation af Homeline™-kombinationsindgangsenheder og HOM/HOMT-afbrydere fra Schneider Electric, der dækker sikkerhedsforanstaltninger, installationstrin og afmonteringsprocedurer.
Preview Schneider Electric I-Line MCCB installations- og produktvælgervejledning
Dette dokument indeholder installationsvejledninger og en produktvælgertabel til Schneider Electrics I-Line støbte afbrydere (MCCB'er), der beskriver enpolede og trepolede modeller med deres specifikationer.
Preview Schneider Electric GV3APN-seriens installations- og sikkerhedsvejledning
Officiel installations- og sikkerhedsvejledning til Schneider Electrics GV3APN-serie motorværnsafbrydere. Dækker modellerne GV3APN01, GV3APN02, GV3APN04 og tilbehør som GVAPK12 og GVAPP1, med detaljerede oplysninger om sikre installationsprocedurer og elektriske sikkerhedsforanstaltninger.
Preview Installationsvejledning til QO® og Homeline® udendørs lastcentre | Schneider Electric
Omfattende installationsvejledning og sikkerhedsforanstaltninger til Schneider Electrics QO® og Homeline® udendørs lastcentre (klasse 1100). Lær, hvordan du monterer, tilslutter og strømforsyner dit lastcenter sikkert.