Dwyer WMT2-B-C-11-1

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output User Manual

1. Produktet er slutview

The Dwyer Series WMT2 Multi-Jet Water Meter is engineered for commercial and industrial applications requiring accurate water flow measurement. Its multi-jet design ensures reliable performance and accuracy across a broad range of flow rates, including low-flow conditions. The meter is built for durability and minimal maintenance, even in challenging environments. It features a magnetically driven, hermetically sealed register that prevents leaks and fogging, completely isolating it from the water flow. A reed switch, activated by a magnet on the dial, generates a pulsed output directly proportional to the flow rate. This output is suitable for remote monitoring of flow rate or totalization and can be integrated with PLCs, counters, data loggers, and SCADA systems.

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output

Image 1.1: The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter, showing its brass body, blue casing, and the meter face with a pulsed output connection.

2. Sikkerhedsoplysninger

WARNING: This product is NOT FOR POTABLE WATER USE. The brass construction contains lead in excess of low-lead limits. Do not use this meter in applications where water will be consumed by humans or animals.

Always ensure proper installation by qualified personnel to prevent leaks and ensure accurate operation. Adhere to all local codes and regulations regarding plumbing and electrical connections.

3. Produktfunktioner

  • Multi-Jet Design: Provides high accuracy and wide flow range capabilities.
  • Pulsed Output: Equipped with a reed switch for remote monitoring and integration with control systems.
  • Hermetically Sealed Register: Magnetically driven, preventing leaks and fogging for clear readings.
  • Holdbar konstruktion: Designed for long service life in commercial and industrial settings.
  • Messinghus: Robust construction for demanding applications.

4. Specifikationer

SpecifikationVærdi
ModelWMT2-B-C-11-1
Koblingsstørrelse1" BSPT
Maksimal flowhastighed7 m³/t
Nominel flowhastighed0.25 til 3.5 m³ / h
Transitional Flow Rate0.07 m³/t
Pulsfrekvens1 gallon per pulse
Maksimal temperatur104°F (40°C)
Maksimalt tryk232 psi (16 bar)
Elektriske forbindelserColor-coded lead wires, 4.5' (1.5 m) long
Varens vægt13.52 pund
FabrikantDwyer Instruments, Inc.

5. Opsætning og installation

Installation of the Dwyer WMT2-B-C-11-1 water meter should be performed by a qualified professional in accordance with all applicable local and national plumbing and electrical codes.

  1. Valg af sted: Choose a location that is easily accessible for reading and maintenance, protected from freezing temperatures, and where the meter can be installed horizontally with the flow arrow pointing in the direction of water flow.
  2. Rørforberedelse: Ensure the piping is clean and free of debris before installation. Use appropriate pipe thread sealant on the 1" BSPT couplings.
  3. Mekanisk installation: Install the meter into the pipeline, ensuring a tight, leak-free connection. The meter should be installed in a straight run of pipe, ideally with at least 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream for optimal accuracy.
  4. Elektrisk tilslutning: Connect the color-coded lead wires from the pulsed output to your remote monitoring system (PLC, counter, data logger, SCADA). Refer to your system's documentation for specific wiring requirements. Ensure all electrical connections are secure and properly insulated.
  5. Lækagetjek: After installation, slowly open the water supply to the meter and check for any leaks at the connections.

6. Betjeningsvejledning

Once installed and the water supply is restored, the Dwyer WMT2-B-C-11-1 meter will begin measuring water flow. The meter's register displays the totalized volume of water that has passed through it. The pulsed output provides an electrical signal (1 pulse per gallon) that can be used by external devices for remote monitoring and data logging.

  • Reading the Meter: The main display on the meter face shows the total accumulated volume. Smaller dials may indicate fractional units for more precise readings.
  • Pulsed Output: The reed switch generates a pulse for every gallon of water that flows through the meter. Connect the lead wires to a compatible device (e.g., PLC, counter) to record these pulses and calculate flow rate or total volume remotely.
  • Strømningsretning: Ensure water flows in the direction indicated by the arrow on the meter body for accurate measurement.

7. Vedligeholdelse

The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter is designed for relatively maintenance-free operation. However, periodic checks are recommended to ensure continued accuracy and performance:

  • Visuel inspektion: Regularly inspect the meter for any signs of physical damage, leaks, or corrosion.
  • Register Clarity: Ensure the hermetically sealed register remains clear and free of fogging, allowing for easy reading.
  • Forbindelsesintegritet: Verify that all plumbing and electrical connections remain secure and free of corrosion.
  • Rensning: If the exterior of the meter becomes dirty, wipe it with a damp klæde. Brug ikke skrappe kemikalier eller slibende rengøringsmidler.

No internal user-serviceable parts are present. Do not attempt to disassemble the meter, as this will void the warranty and may damage the device.

8. Fejlfinding

If you encounter issues with your Dwyer WMT2-B-C-11-1 water meter, consider the following troubleshooting steps:

  • No Flow Reading:
    • Check if water is actually flowing through the pipe.
    • Verify the meter is installed with the flow arrow in the correct direction.
    • Inspect for any blockages upstream or downstream of the meter.
  • Upræcise læsninger:
    • Ensure the meter is installed horizontally.
    • Check for air in the pipeline, which can affect accuracy.
    • Verify that the flow rate is within the meter's specified nominal flow range.
  • No Pulsed Output:
    • Confirm that water is flowing through the meter and the mechanical register is advancing.
    • Check the electrical connections of the lead wires to your monitoring device.
    • Ensure the monitoring device is correctly configured to receive pulses.
  • Lækager ved tilslutninger:
    • Spænd forbindelserne omhyggeligt, og sørg for ikke at overspænde.
    • If necessary, drain the system, reapply pipe thread sealant, and reassemble.

If problems persist after performing these checks, contact Dwyer Instruments, Inc. technical support for assistance.

9. Garanti og support

For information regarding the product warranty, technical support, or replacement parts, please contact Dwyer Instruments, Inc. directly or visit their official website. Keep your purchase receipt and product model number (WMT2-B-C-11-1) readily available when seeking support.

Relaterede dokumenter - WMT2-B-C-11-1

Preview Dwyer Series 477AV Håndholdt Digitalt Manometer: Specifikationer, installations- og betjeningsvejledning
Omfattende guide til Dwyer Series 477AV håndholdt digitalt manometer, der dækker specifikationer, installation, betjeningsvejledning, funktioner og vedligeholdelse af tryk-, flow- og hastighedsmålinger.
Preview Dwyer-seriens IEF-indsætningselektromagnetiske flowtransmitter: Installations- og driftsvejledning
Dette dokument indeholder omfattende specifikationer, installationsvejledninger og betjeningsvejledninger til Dwyer-seriens IEF-indsætningselektromagnetiske flowtransmitter, der beskriver dens funktioner, anvendelser og kommunikationsprotokoller til måling af industriel væskehastighed.
Preview Dwyer Flow Measurement and Control Products: A Comprehensive Selection Guide
Explore Dwyer Instruments' extensive range of flowmeters, flow switches, and flow transmitters. This guide provides detailed specifications and selection criteria to help identify the optimal product for your industrial or commercial application.
Preview Dwyer-serien VFC Visi-Float flowmålere – hurtigstartguide
En hurtigstartguide til Dwyer-serien af ​​VFC Visi-Float-flowmålere, der indeholder vigtige installations-, monterings- og aflæsningsinstruktioner samt vigtige driftsforholdsregler.
Preview Dwyer-serien TUF ultralydsenergimålere: Flow- og temperaturovervågning
Detaljerede specifikationer, funktioner, anvendelser og bestillingsoplysninger for Dwyer-serien af ​​TUF ultralydsenergimålere, designet til præcis flow- og temperaturovervågning med Modbus®- eller BACnet-kommunikation.
Preview Dwyer Process Automation Produktapplikationer og udvælgelsesvejledninger
Udforsk Dwyer Instruments' omfattende guide til procesautomation, der dækker produktanvendelser og -valg til HVAC, vandbehandling, olie og gas og meget mere. Opdag instrumentløsninger til tryk, flow, niveau, temperatur og luftkvalitet.