Drayton ZA5

Drayton ZA5 Aktuator Brugermanual

Model: ZA5 (Part No. 27650)

Mærke: Drayton

1. Produktet er slutview

The Drayton ZA5 replacement actuator is designed for compatibility with the Drayton 22mm 2-port motorised valve, specifically part number 27100. This actuator is a critical component in central heating systems, responsible for controlling the flow of water to a specific heating zone by opening and closing the associated valve.

Drayton ZA5 Zone Valve Actuator with 5-wire cable

An image showing the Drayton ZA5 Zone Valve Actuator, a white rectangular unit with a label detailing its specifications, connected to a black cable with five colored wires (red, orange, green, blue, grey) at the end.

2. Sikkerhedsoplysninger

Always prioritize safety when working with electrical and heating systems. Failure to follow these instructions could result in electric shock, fire, or personal injury.

  • WARNING: DISCONNECT SUPPLY BEFORE REMOVING COVER. Ensure the main electrical supply to the heating system is completely switched off at the consumer unit/fuse box before attempting any installation, maintenance, or removal of the actuator cover.
  • Installation should only be performed by a qualified electrician or heating engineer.
  • Betjen ikke aktuatoren, hvis den ser ud til at være beskadiget.
  • Sørg for, at alle ledningsforbindelser er sikre og overholder lokale el-forskrifter.
  • Keep the actuator dry and away from excessive moisture.

3. Nøglefunktioner

  • Drayton Part Number: 27650
  • 5-Wire configuration for comprehensive control.
  • Direct replacement for the Drayton 27100 Motorised Valve actuator.
  • Designed for zone valve applications in central heating systems.

4. Tekniske specifikationer

SpecifikationVærdi
MærkeDrayton
Modelnummer27650
Produktdimensioner9.5 x 6 x 6 cm
Varens vægt535 g
Voltage230 volt
Frekvens50 Hz
Strømforbrug6 watt
Maks. Omgivelsestemperatur52°C
Max. System Pressure125 psi
Skift vurdering3(1)A

5. Installationsvejledning

This section provides general guidance for replacing a Drayton ZA5 actuator. Always refer to the specific wiring diagrams provided with your heating system and consult a qualified professional if unsure.

Nødvendige værktøjer:

  • Skruetrækker sæt
  • Trådstrippere/skærere
  • Voltage tester

Installationstrin:

  1. Sluk: Locate the main electrical supply to your central heating system and switch it off at the consumer unit/fuse box. Verify that power is off using a voltage tester.
  2. Access Actuator: Identify the existing actuator on your 2-port motorised valve. It is typically secured by screws or clips.
  3. Afbryd ledninger: Carefully note or photograph the existing wiring connections. Disconnect the five wires from the terminal block.
  4. Fjern den gamle aktuator: Unscrew or unclip the old actuator from the valve body. The valve body itself usually remains in place.
  5. Installer ny aktuator: Position the new Drayton ZA5 actuator onto the valve body, ensuring it aligns correctly. Secure it with the provided screws or clips.
  6. Tilslut ledninger: Connect the five wires of the new actuator to the terminal block, matching the connections noted in step 3. The typical wire colors and functions are:
    • Brown: Live (Switched Live from programmer/thermostat)
    • Blå: Neutral
    • Grøn/Gul: Jord
    • Orange: Switched Live (to boiler/pump)
    • Grey: Return (from valve microswitch)
  7. Sikker dækning: Ensure all wires are neatly tucked away and secure the actuator cover.
  8. Gendan strøm: Switch the main electrical supply back on.
  9. Test system: Test the heating system to ensure the actuator operates correctly, opening and closing the zone valve as commanded by the thermostat or programmer.

6. Betjeningsvejledning

The Drayton ZA5 actuator operates automatically as part of your central heating system. It does not require manual intervention for its primary function.

  • When the thermostat calls for heat in the zone controlled by the valve, the actuator receives an electrical signal, causing it to open the valve.
  • Once the thermostat's set temperature is reached, or the heating program ends, the electrical signal is removed, and the actuator closes the valve, typically via a spring return mechanism.
  • A small lever or button may be present on the actuator for manual override or to check valve operation during installation. Refer to your heating system's overall manual for specific instructions on using this feature, if available.

7. Vedligeholdelse

The Drayton ZA5 actuator is designed to be maintenance-free under normal operating conditions. No user-serviceable parts are inside the unit.

  • Keep the exterior of the actuator clean and free from dust and debris. Use a dry cloth for cleaning.
  • Do not attempt to lubricate any internal components.
  • Periodically check the wiring connections for any signs of wear or looseness. Ensure power is off before inspecting connections.
  • If the actuator shows signs of damage or malfunction, it should be replaced by a qualified professional.

8. Fejlfinding

If you experience issues with your heating system that you suspect are related to the zone valve actuator, consider the following common problems and solutions:

ProblemMulig årsagLøsning
No heat in zoneActuator not opening valve; no power to actuator; faulty thermostat/programmer.Check thermostat setting. Verify power to actuator (with power off, check wiring). Replace actuator if it does not respond to power.
Zone always hot (heating won't turn off)Actuator stuck open; faulty microswitch in actuator; wiring fault.Check if actuator returns to closed position when power is off. If not, replace actuator. Check wiring for shorts.
Actuator makes buzzing noise but doesn't moveMotor fault; obstruction in valve.Replace actuator. Check valve for mechanical obstruction (requires draining system).
Actuator feels hot to touchNormal operation (slight warmth); internal fault (excessive heat).Slight warmth is normal. If excessively hot, disconnect power and replace actuator.

For persistent issues, it is recommended to contact a qualified heating engineer.

9. Garanti og support

For information regarding the warranty period and terms for your Drayton ZA5 Actuator, please refer to the documentation provided at the time of purchase or contact your retailer. Drayton products are typically covered by a manufacturer's warranty against defects in materials and workmanship.

For technical support or further assistance, please contact Drayton customer service or visit their official website. Ensure you have your product model number (ZA5) and part number (27650) ready when seeking support.

Relaterede dokumenter - ZA5

Preview Drayton TRV4 termostatisk radiatorventil, brugsanvisning
Betjeningsvejledning og tekniske detaljer til Drayton TRV4 termostatisk radiatorventil med to rør. Dækker installation, betjening, områdebegrænsning, frostbeskyttelse og fejlfinding for optimal regulering af rumtemperatur.
Preview Drayton Installationshåndbog: Omfattende guide til varmestyring
Drayton Installationshåndbogen indeholder detaljerede produktoplysninger, specifikationer og ledningsdiagrammer til en bred vifte af Drayton varmestyringer, herunder termostater, tidsafbrydere, programmeringsenheder og ventiler, hvilket er essentielt for professionelle installatører.
Preview Drayton automatisk afbalancerende TRV installations- og betjeningsvejledning
Omfattende vejledning til installation og betjening af Draytons termostatiske radiatorventiler med to rør og automatisk indregulering, der sikrer effektiv opvarmning af boligen og forbedret kedeleffektivitet.
Preview Installationsvejledning til Drayton automatisk bypassventil
Officiel installationsvejledning til Drayton automatiske bypassventil (ABV). Lær om bygningsreglementer, systemintegration, indstillingsprocedurer, funktioner og tekniske specifikationer for effektiv drift af varmesystemet.
Preview Opsætningsvejledning til Wiser Smart Heating System | Drayton
Trin-for-trin-guide til opsætning af dit Drayton Wiser multizone smart varmesystem, inklusive oprettelse af konto, Hub-forbindelse og funktionerview.
Preview Installationsvejledning og tekniske specifikationer til Drayton RTS-termostat
Omfattende installationsvejledning, tekniske data og ledningsdiagrammer til Drayton RTS-serien af ​​termostater (RTS1, RTS2, RTS3, RTS4, RTS9, RTS10). Indeholder modeloplysninger, placeringsråd, monteringstrin og kompatibilitetsoplysninger.