This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4098-9733 Heat Detector. Adherence to these instructions is crucial for ensuring the detector's optimal performance and compliance with safety standards.

1.1 Formålet med denne manual

The purpose of this document is to guide qualified personnel through the necessary steps for deploying and managing the Simplex 4098-9733 Heat Detector within a fire alarm system. It covers technical specifications, installation procedures, operational guidelines, and maintenance recommendations.

1.2 Vigtige sikkerhedsoplysninger

Overhold altid følgende sikkerhedsforanstaltninger:

2. Produktet er slutview

The Simplex 4098-9733 is a fixed-temperature heat detector designed to provide reliable fire detection by responding to a specific temperature threshold. It is typically integrated into a larger fire alarm system.

2.1 Nøglefunktioner

2.2 Produktkomponenter

The Simplex 4098-9733 Heat Detector consists of the main detector head and typically requires a compatible mounting base (sold separately) for installation into a fire alarm circuit.

A box filled with multiple red Simplex 4098-9733 heat detectors, each individually packaged in clear plastic.

This image displays a cardboard box containing numerous Simplex 4098-9733 heat detectors. Each detector is red, circular, and encased in clear plastic packaging, indicating new, unused units ready for installation.

3. Opsætning og installation

3.1 Før installation

3.2 Montering af detektoren

The 4098-9733 detector requires a compatible mounting base (e.g., Simplex 4098-9792, 4098-9789, or similar, sold separately) for proper installation.

  1. Turn off all power to the fire alarm control panel and associated circuits.
  2. Mount the detector base securely to a standard electrical box or directly to the ceiling/wall according to local codes.
  3. Connect the wiring from the fire alarm control panel to the appropriate terminals on the detector base (refer to the wiring diagram below).
  4. Align the detector head with the mounting base and rotate clockwise until it locks into place.
  5. Restore power to the fire alarm control panel and test the detector.

3.3 Ledningsføring

Proper wiring is critical for the detector's functionality. Refer to the specific wiring diagram provided with your detector base and fire alarm control panel documentation. A typical wiring configuration for a two-wire system is as follows:

Typical Wiring Connections (Consult Base Manual for Specifics)
TerminalBeskrivelse
1Signal Line In (+)
2Signal Line Out (+)
3Signal Line In/Out (-)
4Remote Annunciator (if applicable)

4. Betjeningsvejledning

4.1 Normal drift

Under normal conditions, the Simplex 4098-9733 Heat Detector continuously monitors the ambient temperature. It draws minimal current from the fire alarm control panel and typically has an indicator LED that may flash periodically to confirm normal operation (check your specific base and panel documentation for LED behavior).

4.2 Alarmtilstand

When the ambient temperature at the detector reaches or exceeds 135°F (57°C), the detector will activate. This activation sends a signal to the fire alarm control panel, initiating the alarm sequence (e.g., sounding alarms, notifying monitoring stations). The detector's LED will typically illuminate steadily to indicate its alarm state.

Upon an alarm, follow your facility's emergency procedures immediately. Do not attempt to reset the detector until the cause of the alarm has been identified and resolved.

5. Vedligeholdelse

Regular maintenance is essential to ensure the continued reliability and proper functioning of your heat detector.

5.1 Regelmæssig inspektion

5.2 Rengøring

If dust or debris is visible, clean the exterior of the detector using a soft, dry cloth. Do not use cleaning sprays or solvents directly on the detector. For more thorough cleaning, consult a qualified fire alarm technician.

5.3 Afprøvning

Heat detectors should be tested periodically by qualified personnel in accordance with NFPA 72 and local fire codes. Testing typically involves applying a controlled heat source to the detector to verify its activation at the rated temperature. Never use an open flame for testing.

6. Fejlfinding

This section addresses common issues that may arise with the Simplex 4098-9733 Heat Detector. For complex problems, contact a qualified fire alarm technician.

ProblemMulig årsagLøsning
Detector not responding to heat testIncorrect wiring, faulty detector, insufficient heat applied, incompatible base.Verify wiring connections. Ensure adequate heat is applied during testing. Check detector compatibility with base and panel. Replace detector if faulty.
Falske alarmerDetector located near heat source (e.g., furnace, oven), environmental factors.Relocate detector away from heat sources. Ensure proper ventilation. Consult installation guidelines for appropriate placement.
System trouble signalWiring fault, detector not seated correctly, power issue.Check all wiring connections. Ensure detector is securely twisted onto its base. Verify power supply to the fire alarm control panel.

7. Tekniske specifikationer

The following table outlines the technical specifications for the Simplex 4098-9733 Heat Detector:

SpecifikationDetalje
Modelnummer4098-9733
SensortypeFixed Temperature Heat Detector
Aktiveringstemperatur135°F (57°C)
AlarmtypeAudible (via control panel)
DriftsfugtighedOp til 90 % ikke-kondenserende
StrømkildePowered by Fire Alarm Control Panel (not battery operated)
MaterialeMetal, Plast
FarveRød, hvid
Varens vægt3.2 ounce (ca.)
Produktdimensioner5 x 5 x 3 tommer (ca.)
UPC643485652892

8. Garanti og support

8.1 Garantioplysninger

Simplex products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the official warranty statement provided with your purchase or contact Simplex customer service. Keep your proof of purchase for warranty claims.

8.2 Teknisk support

For technical assistance, troubleshooting beyond this manual, or to inquire about service, please contact your authorized Simplex distributor or a qualified fire alarm service provider. Ensure you have the model number (4098-9733) and any relevant system information available when seeking support.

Relaterede dokumenter - 4098-9733

Preview Simplex TrueAlarm analoge sensorer: Fotoelektriske og varme datablad
Omfattende datablad for Simplex TrueAlarm analoge sensorer, med detaljerede oplysninger om fotoelektriske og varmemodeller, standardbaser og tilbehør. Indeholder funktioner, intelligent dataevaluering, sensorspecifikationer, monteringsreferencer og produktvalgsdiagrammer til brandalarmsystemer.
Preview Simplex 4098-9019 IDNet adresserbar stråledetektor ledningsføring og FACP programmeringsvejledning
Omfattende vejledning til ledningsføring og programmering af Simplex 4098-9019 IDNet adresserbar stråledetektorsystem med Simplex brandalarmcentraler (FACP'er). Dækker kompatibilitet, elektriske specifikationer, adressering og centralbetjening.
Preview Simplex 4098 Detektorer, Sensorer og Baser Applikationsmanual
Denne applikationsmanual giver omfattende information om korrekt brug og installation af Simplex 4098-seriens detektorer, sensorer og baser i brandalarmsystemer. Den dækker driftsprincipper, placeringsretningslinjer, kompatibilitet, testprocedurer og fejlfinding for disse kritiske brandsikkerhedskomponenter.
Preview Simplex 4008/4006-9801 Expansion Power Supply (EPS) Installation Guide
Installation instructions for the Simplex 4008/4006-9801 Expansion Power Supply (EPS), detailing mounting, panel interconnections, NAC wiring, auxiliary power, and NAC ratings for fire alarm systems.
Preview Simplex 2098-seriens røgdetektorer: Installationsvejledning og specifikationer
Dette dokument indeholder installationsvejledninger, tekniske specifikationer og ledningsdiagrammer for Simplex 2098-9201, 2098-9202, 2098-9203, 2098-9208 og 2098-9576 røgdetektorer, der dækker både fotoelektriske og ioniserende typer. Det beskriver generelle oplysninger, særlige overvejelser ved installation, anvendelser, vedligeholdelse, testprocedurer og begrænsninger ved røgdetektionsteknologi.
Preview Simplex 4010 brandalarm: Installations-, betjenings- og programmeringsvejledning
Omfattende vejledning til installation, betjening og programmering af Simplex 4010 brandalarmsystemet. Dækker systemet overview, ledningsføring, konfiguration, diagnosticering og fejlfinding.