Indledning
This user manual provides comprehensive instructions for the proper use, maintenance, and care of your Rossmax EB100 Stethoscope. Designed for medical professionals, nurses, and students, this device offers high acoustic sensitivity for accurate auscultation of heart and lung sounds. Please read this manual thoroughly before first use to ensure optimal performance and longevity of your stethoscope.
Produkt overview
The Rossmax EB100 Stethoscope is a professional-grade diagnostic instrument featuring a single-head design and high acoustic sensitivity. Its ergonomic construction ensures comfort during extended use.

Figure 1: Rossmax EB100 Stethoscope, showcasing its black tubing and silver chest piece.

Figure 2: The EB100 Stethoscope, designed for proficient practitioners.
Nøglekomponenter:
- Bryststykke: Single-head design, typically made of aluminum, for sound collection.
- Rør: High-quality, flexible tubing for sound transmission.
- Headset: Includes binaurals and ear tips for comfortable listening.
- Ørespidser: Soft, ergonomic ear tips for a comfortable and secure fit, ensuring acoustic seal.
Opsætning
Before using your Rossmax EB100 Stethoscope, ensure all components are securely assembled and clean.
- Efterse komponenter: Carefully unbox the stethoscope and inspect all parts for any visible damage or defects. Ensure the chest piece, tubing, and headset are intact.
- Fastgør ørepropper: If not already attached, firmly push the soft ear tips onto the binaural tubes. Ensure they are seated correctly to provide an acoustic seal and comfort.
- Adjust Headset Tension: The headset should fit comfortably in your ears. Gently adjust the binaural tubes to achieve a snug but not overly tight fit. The ear tips should point forward, aligning with your ear canals.

Figure 3: Stethoscope and its packaging, indicating initial setup components.

Figure 4: Key features including aluminum chest piece and soft ear tips, important for setup and comfort.
Betjeningsvejledning
The Rossmax EB100 Stethoscope is designed for effective auscultation. Follow these steps for optimal performance:
- Positioning the Headset: Place the ear tips into your ears, ensuring a comfortable and snug fit. The ear tips should point slightly forward to align with the natural angle of your ear canals.
- Using the Chest Piece: The EB100 features a single-sided chest piece (diaphragm). Place the diaphragm firmly against the patient's skin over the area you wish to auscultate (e.g., heart, lungs, abdomen).
- Auscultation: Listen carefully to the sounds transmitted through the stethoscope. Apply appropriate pressure to the chest piece to ensure good skin contact and minimize ambient noise interference.
- Lydklarhed: The high acoustic sensitivity of the EB100 allows for clear detection of subtle body sounds. Practice in a quiet environment to familiarize yourself with normal and abnormal sounds.

Figure 5: Proper technique for using a stethoscope during examination.

Figure 6: The chest piece designed for achieving perfect results in sound detection.
Vedligeholdelse og pleje
Proper maintenance ensures the longevity and hygienic use of your stethoscope.
- Rensning: After each use, wipe the chest piece, tubing, and ear tips with a 70% isopropyl alcohol solution or a mild soap and water solution. Do not immerse the stethoscope in any liquid.
- Desinfektion: For more thorough disinfection, follow your institution's guidelines for medical equipment. Ensure the stethoscope is completely dry before storage.
- Opbevaring: Store your stethoscope in a clean, dry place, away from extreme temperatures, direct sunlight, and sharp objects that could damage the tubing. Avoid tightly coiling the tubing to prevent kinks.
- Inspektion: Regularly check the ear tips for wear and tear, and the tubing for cracks or hardening. Replace components as needed to maintain acoustic performance.
Fejlfinding
If you experience issues with your Rossmax EB100 Stethoscope, refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Dårlig eller ingen lyd | Ear tips not sealed; tubing blocked or cracked; chest piece not making good contact. | Ensure ear tips are snug and correctly oriented. Check tubing for obstructions or damage. Apply firm, even pressure to the chest piece. |
| Ambient Noise Interference | Loose ear tips; noisy environment. | Adjust ear tips for a tighter seal. Perform auscultation in a quiet environment. |
| Discomfort from Ear Tips | Incorrect size or positioning of ear tips. | Ensure ear tips are correctly angled and not too tight. Consider alternative ear tip sizes if available. |
Specifikationer
The following are the technical specifications for the Rossmax EB100 Stethoscope:
- Modelnavn: EB100
- Varemodelnummer: RXEB100
- Farve: Sort
- Materiale: Aluminium (Chest Piece)
- Varens vægt: 1.73 kilogram (1 kg 730 g)
- Produktdimensioner: 9 x 2 x 9 cm
- Anbefalede anvendelser: Heart Beat, Lung Sound Auscultation
- Global Trade Identification Number (GTIN): 04715139000369
- Fabrikant: Rossmax International Ltd.
- Oprindelsesland: Kina
Garanti og support
Rossmax products are designed for durability and reliability. For specific warranty information, please refer to the warranty card included with your product or contact Rossmax customer support.
Kundesupport:
For technical assistance, replacement parts, or warranty claims, please contact the manufacturer directly:
- Fabrikant: Rossmax International Ltd.
- Adresse: 12F, nr. 189, Kang Chien Road, Taipei, 114, Taiwan
- Telefon: 9972528266