Aiphone LEF-10S

Aiphone Call Audio Master Station LEF-10S User Manual

Model: LEF-10S

Produkt overview

The Aiphone LEF-10S is a Call Audio Master Station designed for indoor use. It functions as a central communication unit, capable of connecting to multiple door stations or other sub-stations. This model supports 20 conductors, making it suitable for complex intercom systems. It operates on 12VDC power and is compatible with the Aiphone LE Series.

Aiphone LEF-10S Call Audio Master Station, front view

Figur 1: Forside view of the Aiphone LEF-10S Call Audio Master Station, showing the speaker grille, control buttons, and indicator lights.

Opsætning og installation

Proper installation is crucial for optimal performance. This unit requires a 12VDC power source and appropriate wiring for connection to door stations or other LE Series components.

Montering

The LEF-10S includes mounting hardware. Select a suitable indoor location, preferably near the central wiring point for your intercom system. Ensure the mounting surface is stable and can support the unit's weight.

Ledningsføring

The LEF-10S supports 20 conductors. Use shielded wire for best performance, especially over longer distances. Refer to the wiring diagram specific to your LE Series system configuration.

Betjeningsvejledning

The LEF-10S provides clear audio communication and call management for your intercom system.

Foretag et opkald

  1. Identify the button corresponding to the desired door station or sub-station.
  2. Press the call button. The station will ring, and an indicator light may illuminate.
  3. Tal tydeligt ind i mikrofonen.
  4. To end the call, press the "OFF" button or wait for the call to terminate automatically.

Modtagelse af et opkald

  1. When a call is received, the unit will chime, and the corresponding station's indicator light will flash.
  2. Press the "TALK" button to answer the call.
  3. Speak into the microphone to communicate.
  4. To end the call, press the "OFF" button.

Lydstyrkejustering

Adjust the speaker volume using the dedicated volume control knob or buttons on the unit. Test the volume to ensure clear audio without distortion.

Opretholdelse

The Aiphone LEF-10S requires minimal maintenance to ensure long-term reliable operation.

Fejlfinding

If you encounter issues with your LEF-10S master station, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Ingen lyd fra højttalerenVolume too low; Loose wiring; Faulty speakerIncrease volume; Check all wiring connections; Contact support if speaker is faulty.
Kan ikke foretage eller modtage opkaldNo power; Incorrect wiring; Faulty stationVerify 12VDC power supply; Check all wiring connections for correct polarity and security; Test with another station if possible.
Forvrænget lydVolume too high; Interference; Damaged wiringDecrease volume; Ensure shielded wire is used and properly grounded; Inspect wiring for damage.

If the problem persists after attempting these solutions, please contact Aiphone technical support.

Specifikationer

Garanti og support

Aiphone products are designed for reliability and durability. For specific warranty information, please refer to the documentation included with your purchase or visit the official Aiphone webGarantibetingelserne dækker typisk fabrikationsfejl i en bestemt periode fra købsdatoen.

For technical assistance, troubleshooting beyond this manual, or to inquire about replacement parts, please contact Aiphone customer support. You can usually find contact information on the manufacturer's webwebsted eller i produktemballagen.

Aiphone Officiel Webwebsted: www.aiphone.com

Relaterede dokumenter - LEF-10S

Preview Aiphone LEF-LD Højttaler Intercom System: Instruktioner og ledningsføring
Detaljerede instruktioner og ledningsdiagrammer til Aiphone LEF-LD langdistancehøjttaler-intercomsystemet, der dækker modellerne LEF-3-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD, LEF-3C-LD, LEF-5C-LD og LEF-10C-LD.
Preview Aiphone MY-serien PanTilt dørstation MY-DC/A, MY-DG/A installations- og betjeningsmanual
Omfattende installations- og betjeningsmanual til Aiphone MY-serien PanTilt-dørstationer, modellerne MY-DC/A og MY-DG/A. Dækker system overview, funktioner, komponenter, ledningsføring, montering, betjening, tekniske specifikationer og garanti.
Preview Aiphone IC-1AD(U) Intercom-system med dørklokke og tone: Installations- og betjeningsvejledning
Omfattende guide til Aiphone IC-1AD(U) intercom-systemet med 1 dør og 1 rum, der dækker funktioner, specifikationer, installation, ledningsføring, betjening og garanti.
Preview Installationsmanual til Aiphone EL-12S elektrisk dørslag
Comprehensive installation manual for the Aiphone EL-12S electric door strike, detailing safety precautions, package contents, wiring diagrams, step-by-step installation guides for built-in and surface mount applications, technical specifications, and warranty information.
Preview Aiphone TW-TA-SP & TW-TE-SP Installationsvejledning: Opsætning af nødopkaldstårn
Omfattende installationsvejledning til Aiphone TW-TA-SP og TW-TE-SP nødopkaldstårne. Dækker opsætning, ledningsføring og IXG Support Tool-konfiguration til nødstationer.
Preview Aiphone LEM-1DLC Master Station Installation and Operation Guide
Detailed installation and operation guide for the Aiphone LEM-1DLC master station, designed for multiple master use with occupied lamp functionality, including wiring diagrams and specifications.