1. Introduktion
The GIMA OXY 6 Finger Pulse Oximeter is a portable device designed for non-invasive spot-checking of arterial oxygen saturation (SpO2) and pulse rate. It is suitable for use in medical and hospital environments, as well as for personal use under medical guidance. This manual provides essential information for the safe and effective operation of the device.
2. Sikkerhedsoplysninger
Please read all safety warnings and precautions before using the device. Failure to do so may result in inaccurate readings or device malfunction.
- This device is intended for spot-checking and not for continuous monitoring.
- Brug ikke oximeteret i et MR- eller CT-miljø.
- Hold enheden væk fra vand og fugt.
- Consult a medical professional for interpretation of readings. This device is not a substitute for professional medical advice.
- Ensure the finger is clean and free of nail polish or artificial nails, as these can affect accuracy.
- Avoid excessive movement during measurement to ensure stable readings.
3. Produktet er slutview
The GIMA OXY 6 features a high-resolution OLED color display showing SpO2, pulse rate, pulse bar graph, perfusion index (PI), and battery level. It is designed for ease of use with a compact form factor.

Figur 1: Front view of the GIMA OXY 6 Pulse Oximeter, displaying SpO2 and pulse rate values on its screen.
3.1. Pakkens indhold

Figur 2: The package includes the GIMA OXY 6 Pulse Oximeter, a plastic case, AAA batteries, and a lanyard.
- GIMA OXY 6 Pulse Oximeter
- 2 x AAA batterier
- Plast bæretaske
- Snor
- Instruktionsmanual

Figur 3: The GIMA OXY 6 Pulse Oximeter attached to a lanyard, demonstrating its portability and ease of carrying.
4. Opsætning
4.1. Batteriinstallation
- Åbn batteridækslet, der er placeret på bagsiden af enheden.
- Insert two AAA batteries according to the polarity indicators (+/-) inside the compartment.
- Luk batterirummets dæksel forsvarligt.

Figur 4: Open battery compartment showing placement for two AAA batteries.
5. Betjeningsvejledning
5.1. At foretage en måling
- Sørg for, at enheden har nye batterier isat.
- Åbn clamp of the oximeter.
- Insert one finger (preferably the index, middle, or ring finger) into the rubber opening of the oximeter, ensuring the finger is fully inserted and resting on the sensor. The recommended finger thickness for this model is 1-22 mm.
- Slip clamp. The device will automatically turn on and begin measurement.
- Keep your hand still during the measurement. Avoid bending your finger or making hand movements.
- Readings for SpO2, Pulse Rate, and Perfusion Index (PI) will appear on the display within a few seconds.

Figur 5: The GIMA OXY 6 Pulse Oximeter correctly placed on a finger for measurement.
5.2. Forståelse af displayet
- SpO2: Peripheral Oxygen Saturation, displayed as a percentage.
- PR: Pulse Rate, displayed in beats per minute (bpm).
- PI: Perfusion Index, a numerical value indicating the strength of the pulse signal at the sensor site.
- Pulse Bar Graph: Visual representation of pulse strength.
- Batteriindikator: Viser det aktuelle batteriniveau.
5.3. Automatisk slukning
The device will automatically power off after approximately 8 seconds of inactivity or when the finger is removed.
5.4. Lav Voltage Alarm
Når batteriet voltage is low, a low voltage alarm will be indicated on the display. Replace the batteries promptly to ensure accurate operation.
5.5. Stemmeguide
The GIMA OXY 6 features an 8-language voice guide (English, French, Italian, Spanish, Greek, Portuguese, Arabic) for enhanced usability. Refer to the full manual for specific instructions on activating and changing voice guide settings.
6. Vedligeholdelse
6.1. Rensning
- Rengør oximeterets overflade med en blød kludampenet med medicinsk alkohol (70% ethanol eller isopropanol).
- Enheden må ikke nedsænkes i vand eller andre rengøringsopløsninger.
- Sørg for, at enheden er helt tør, før den bruges igen.
6.2. Udskiftning af batteri
Udskift batterierne, når den lave voltage indicator appears. Always use two new AAA alkaline batteries. Dispose of used batteries according to local regulations.
6.3. Opbevaring
Store the oximeter in its plastic carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
7. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Intet display efter tænding | Batterierne er døde eller forkert installeret. | Udskift batterierne, eller sæt dem korrekt i igen, og overhold polariteten. |
| Unøjagtige aflæsninger | Finger not properly inserted; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm the finger. |
| "Finger ud" eller lignende fejlmeddelelse | Fingeren er ikke registreret eller placeret forkert. | Ensure finger is fully inserted and resting on the sensor. |
| Enheden slukker uventet | Low battery; automatic power-off due to inactivity. | Replace batteries; ensure finger is inserted for measurement. |
8. Specifikationer
| Modelnummer | 34285 (OXY 6) |
| Display Type | OLED Color Display |
| Måleparametre | SpO2, Pulse Rate, Perfusion Index (PI) |
| SpO2 Measurement Range | (Typical range, refer to device for exact range) |
| Måleområde for pulsfrekvens | (Typical range, refer to device for exact range) |
| Nøjagtighed | High precision and repeatability with noise suppression |
| Strømkrav | 2 x AAA 1.5V Alkaline Batteries |
| Batterilevetid | Approximately 3 hours of continuous operation with full batteries |
| Dimensioner (L x B x H) | 16 x 5.5 x 10 cm |
| Vægt | 200 gram (inklusive batterier) |
| Finger Thickness Range | 1-22 mm |
| Stemmeguide | 8 languages (GB, FR, IT, ES, GR, PT, Arabic) |
9. Garanti og support
Information regarding specific warranty terms and customer support for the GIMA OXY 6 Pulse Oximeter is not provided in this document. Please refer to the product packaging or contact GIMA customer service for details.