OWON SDS5032E

OWON SDS5032E 30MHz Digital Storage Oscilloscope User Manual

Model: SDS5032E

1. Introduktion

This manual provides comprehensive instructions for the safe and effective operation of your OWON SDS5032E Digital Storage Oscilloscope. The SDS5032E is a 2-channel, 30MHz bandwidth oscilloscope designed for accurate signal measurement and analysis. It features an 8-inch TFT color LCD display, a 10k point memory depth, and various connectivity options including USB, LAN, and VGA ports.

Læs venligst denne manual grundigt, inden du bruger enheden, for at sikre korrekt opsætning, betjening og vedligeholdelse.

2. Sikkerhedsoplysninger

To prevent electric shock or personal injury, and to avoid damage to the oscilloscope or connected equipment, observe the following safety precautions:

  • Strømkilde: Connect the oscilloscope only to a power source within the specified voltage range (100-240Vac RMS, 50/60Hz, CAT II).
  • Jording: Ensure the oscilloscope is properly grounded. The power cord supplied with the instrument has a protective grounding conductor.
  • Probe sikkerhed: Use only probes supplied or recommended by OWON. Do not connect the probe ground lead to a point where a voltage greater than 300V RMS exists between ground and the point.
  • Miljøforhold: Operate the oscilloscope in a well-ventilated area. Do not operate in explosive atmospheres or in the presence of flammable gases or fumes. Avoid operating in damp eller våde forhold.
  • Opretholdelse: Refer all servicing to qualified service personnel. Do not attempt to service the instrument yourself.
  • Rensning: Afbryd strømmen før rengøring. Brug en blød, tør klud. Brug ikke flydende rengøringsmidler eller aerosolrengøringsmidler.

3. Opsætning

3.1 Udpakning og indholdsverifikation

Carefully unpack the oscilloscope and all accessories. Verify that all items listed below are present and undamaged. If any items are missing or damaged, contact your supplier.

OWON SDS5032E Digital Storage Oscilloscope with included accessories: two probes, USB cable, power cable, user manual, and software CD.

This image displays the OWON SDS5032E Digital Storage Oscilloscope alongside its standard accessories. These include two oscilloscope probes for signal input, a USB cable for PC connectivity, a power cable for operation, a printed user manual, and a CD containing software and drivers.

Standard package contents include:

  • OWON SDS5032E Digital Storage Oscilloscope
  • Two Oscilloscope Probes (1:1 and 10:1 switchable)
  • Strømkabel
  • USB kabel
  • Brugermanual
  • CD with Software and Drivers

3.2 Strømtilslutning

Connect the supplied power cable to the AC power input on the rear panel of the oscilloscope and then to a grounded AC power outlet. The oscilloscope supports 100-240Vac RMS, 50/60Hz power sources.

3.3 Tilslutning af sonder

Connect the BNC connector of an oscilloscope probe to either the CH1 or CH2 input on the front panel. Ensure the connector is securely twisted into place. Attach the probe ground clip to the circuit's ground point. Set the probe attenuation switch (if available) to the desired setting (e.g., 1X or 10X) and match this setting on the oscilloscope's input channel menu.

3.4 Indledende tænding

Press the power button located on the front panel to turn on the oscilloscope. The device will perform a self-test and display the main waveform interface.

4. Betjeningsvejledning

4.1 Frontpanel overview

Front view of the OWON SDS5032E Digital Storage Oscilloscope, showing the 8-inch LCD screen and control panel.

En fremadvendt view of the OWON SDS5032E oscilloscope, highlighting the large 8-inch LCD display and the array of control buttons and rotary knobs used for adjusting settings and navigating menus.

The front panel features the 8-inch TFT LCD display, various function buttons, and rotary knobs for controlling vertical, horizontal, and trigger settings. Key controls include:

  • Vertikale kontroller: VOLTS/DIV knobs for adjusting vertical scale and POSITION knobs for vertical waveform positioning for each channel (CH1, CH2).
  • Horisontale kontroller: SEC/DIV knob for adjusting the time base and HORIZONTAL POSITION knob for horizontal waveform positioning.
  • Trigger Controls: TRIG LEVEL knob for setting the trigger threshold and various trigger mode buttons.
  • Funktionsknapper: Buttons for Measure, Acquire, Cursor, Utility, Save, Display, Help, Auto Setup, Run/Stop, Single, and Math functions.
  • Menu Buttons (F1-F5): Context-sensitive buttons along the left side of the display for menu navigation.

4.2 Grundlæggende måling

  1. Forbind signal: Connect the probe to the signal source you wish to measure.
  2. Automatisk opsætning: Tryk på Automatisk opsætning button. The oscilloscope will automatically adjust the vertical, horizontal, and trigger settings to display a stable waveform.
  3. Adjust Vertical Scale: Brug VOLT/DIV knob for the active channel (CH1 or CH2) to adjust the vertical scale, making the waveform fill the screen appropriately.
  4. Adjust Horizontal Scale: Brug SEC/DIV knob to adjust the time base, allowing you to view more or less of the waveform horizontally.
  5. Juster udløser: Brug TRIG-NIVEAU knob to stabilize the waveform. The trigger level indicator on the screen shows the current trigger point.
  6. Mål: Tryk på Måle button to access automatic measurement functions (e.g., frequency, peak-to-peak voltage, RMS).

4.3 Connectivity (USB, LAN, VGA)

Side view of the OWON SDS5032E Digital Storage Oscilloscope, illustrating the various input/output ports.

Dette billede viser en sideprofile of the oscilloscope, detailing the connectivity options such as the LAN port, VGA output, and USB host/device ports, which enable data transfer and external display connections.

  • USB-port: Connect a USB flash drive to the USB Host port for saving waveforms, screenshots, or settings. Use the USB Device port to connect the oscilloscope to a PC for data transfer and remote control via the provided software.
  • LAN-port: Connect an Ethernet cable to the LAN port for network connectivity, enabling remote control and data sharing over a local area network. Refer to the software manual for detailed LAN setup.
  • VGA port: Connect an external monitor or projector to the VGA port to display the oscilloscope screen on a larger display, useful for demonstrations or collaborative work.

5. Vedligeholdelse

  • Rensning: Regularly clean the exterior of the oscilloscope with a soft, dry cloth. For stubborn dirt, use a cloth lightly dampened with water and a mild detergent. Ensure no liquid enters the device. Do not use abrasive cleaners or solvents.
  • Skærmpleje: Clean the LCD screen gently with a soft, lint-free cloth. Avoid pressing hard on the screen.
  • Opbevaring: When not in use for extended periods, store the oscilloscope in a dry, dust-free environment, away from direct sunlight and extreme temperatures.
  • Sondekalibrering: Periodically check and calibrate your probes according to the instructions in the full user manual to ensure accurate measurements.

6. Fejlfinding

This section provides solutions to common issues. For more complex problems, refer to the detailed user manual or contact technical support.

  • Ingen strøm:
    • Check if the power cable is securely connected to both the oscilloscope and the power outlet.
    • Kontroller, at stikkontakten fungerer.
    • Sørg for, at tænd/sluk-knappen er i 'ON'-positionen.
  • Ingen skærm/tom skærm:
    • Adjust the intensity/brightness settings if available.
    • Perform an Automatisk opsætning to reset display parameters.
    • If connected to an external VGA display, ensure the external display is powered on and correctly configured.
  • Ustabil bølgeform:
    • Juster TRIG-NIVEAU knob to stabilize the waveform.
    • Check the trigger mode (e.g., Edge, Video) and source settings to ensure they match the input signal.
    • Verify probe connections and ensure the ground clip is properly attached.
  • Intet signal vist:
    • Ensure the probe is correctly connected to the signal source and the oscilloscope input channel.
    • Tjek VOLT/DIV setting; the signal might be too small to be visible.
    • Tjek SEC/DIV setting; the signal might be too fast or too slow.
    • Perform an Automatisk opsætning.

7. Specifikationer

FeatureSpecifikation
Modelnummer01SDS5032E
Båndbredde30 MHz
Kanaler2
Sampling RateUp to 250 MSa/s
Hukommelsesdybde10k points per channel
Vise8-inch TFT 65K color LCD, 800x600 pixel resolution
GrænsefladerUSB (Host & Device), LAN, VGA
Strømforsyning100~240Vac RMS, 50/60Hz, CAT II
Produktdimensioner14 x 3 x 7 tommer
Vægt4.5 pund
FabrikantOwon
Dato først tilgængelig13. september 2012

8. Garanti og support

For warranty information and technical support, please refer to the documentation included with your product or visit the official OWON webwebsted. Du kan også besøge OWON Store on Amazon for yderligere produktinformation og ressourcer.

Relaterede dokumenter - SDS5032E

Preview Brugermanual til OWON PDS-seriens bærbare LCD-oscilloskop med digital lagring
Omfattende brugermanual til OWON PDS-seriens bærbare LCD digitale lagringsoscilloskop, der dækker funktioner, betjening, sikkerhed, fejlfinding og tekniske specifikationer.
Preview OWON PDS Series Digital Storage Oscilloscope User Manual
Comprehensive user manual for the OWON PDS Series Portable Colour Digital Storage Oscilloscopes, detailing operation, features, safety, and technical specifications for models PDS5022S, PDS6042S, PDS6062S, PDS6062T, PDS7062T, and PDS7102T.
Preview OWON PDS5022S Digitalt Lagringsoscilloskop Brugermanual
Omfattende brugermanual til OWON PDS5022S bærbart digitalt farveoscilloskop, der dækker betjening, sikkerhed, funktioner og tekniske specifikationer.
Preview Brugermanual til OWON TAO3000-serien af ​​håndholdte oscilloskoper
Brugermanual til OWON TAO3000 håndholdte oscilloskoper i firekanalers serien, med detaljer om betjening, funktioner, tekniske specifikationer og fejlfinding.
Preview OWON HDS200-seriens 2-kanals bærbare oscilloskop – hurtigstartguide
Denne hurtigstartvejledning indeholder vigtige oplysninger om betjening af OWON HDS200-serien af ​​2-kanals bærbare oscilloskoper, inklusive modellerne HDS272, HDS242, HDS2102 og HDS2202. Den dækker sikkerhedsforanstaltninger, generel inspektion, brug af oscilloskop og multimeter, signalgeneratorfunktioner, softwaretilslutning, fejlfinding og vedligeholdelse.
Preview Brugermanual til OWON HDS200-seriens håndholdte oscilloskop - Betjening og specifikationer
Denne omfattende brugermanual indeholder detaljerede instruktioner til betjening af OWON HDS200 Dual Channel-serien af ​​håndholdte oscilloskoper, inklusive modellerne HDS272(S) og HDS242(S). Den dækker sikkerhedsoplysninger, generel inspektion, oscilloskop, multimeter og valgfrie bølgeformgeneratorfunktioner, sammen med tekniske specifikationer og vedligeholdelsesretningslinjer.