Fluke FLUKE-325

Fluke 325 True-RMS Clamp Måler: Brugervejledning

1. Produktet er slutview

The Fluke 325 True-RMS Clamp Meter is a versatile and reliable tool designed for general electrical troubleshooting. It accurately measures AC current, AC and DC voltage, resistance, frequency, temperature, and capacitance. Its compact design and robust construction make it suitable for various industrial and residential applications.

Fluke 325 True-RMS Clamp Måler

Billede: Forside view of the Fluke 325 True-RMS Clamp Meter, displaying its digital screen and function dial.

Nøglefunktioner:

  • Digital clamp meter measures AC current up to 400 A, AC and DC voltage up to 600 V, and resistance up to 4 kΩ.
  • True-RMS sensing provides accurate readings for linear and non-linear loads.
  • Jaw opening of 30 mm allows current measurement without interrupting the circuit.
  • Audible continuity sensor for quick circuit checks.
  • Meets IEC safety standard 61010-1, rated for CAT IV installations to 300 V and CAT III installations to 600 V.
  • Includes frequency, temperature, and capacitance measurement capabilities.

2. Vigtige sikkerhedsoplysninger

Always read and understand the safety instructions before using the Fluke 325 Clamp Meter. Failure to follow safety warnings can result in serious injury or death.

  • Brug ikke måleren, hvis den er beskadiget eller fungerer unormalt.
  • Verify the meter's operation on a known voltage source before use.
  • Vær forsigtig, når du arbejder med voltages above 30 V AC RMS, 42 V AC peak, or 60 V DC. These voltages udgør en stødfare.
  • Always use the proper terminals, function, and range for your measurements.
  • Keep fingers behind the finger guards on the test probes.
  • The Fluke 325 is rated for CAT IV 300 V and CAT III 600 V. Ensure the meter's rating is appropriate for the environment where it will be used.

3. Kom godt i gang: Opsætning

Installation af batteri

The Fluke 325 requires two AA batteries (included). To install or replace batteries:

  1. Sørg for, at måleren er slukket.
  2. Find batterirummet på bagsiden af ​​måleren.
  3. Brug en skruetrækker til at åbne batteridækslet.
  4. Insert two AA batteries, observing correct polarity.
  5. Sæt batterirummets dæksel på igen og fastgør det med skruen.

Tilslutning af prøveledninger

For bdtage, resistance, continuity, frequency, temperature, and capacitance measurements, connect the test leads to the appropriate input jacks:

  • Insert the black test lead into the COM (common) jack.
  • Insert the red test lead into the VΩHz jack for most measurements.
Fluke 325 Clamp Meter with included test leads and carrying case

Image: The Fluke 325 Clamp Meter displayed with its test leads, temperature probe, and soft carrying case.

4. Operating Your Fluke 325

Funktionsvælger

The large yellow rotary dial on the front of the meter is used to select the desired measurement function. Turn the dial to the appropriate setting for your task.

AC/DC Current Measurement (Clamp)

Sådan måler du AC- eller DC-strøm:

  1. Turn the function dial to the ∼A (AC current) or =A (DC current) position.
  2. Åbn clamp jaws by pressing the lever.
  3. Place the jaws around a single conductor. Ensure the jaws are fully closed.
  4. Aflæs den aktuelle værdi på displayet.
Electrician using Fluke 325 Clamp Meter to measure current in an electrical panel

Image: A gloved hand using the Fluke 325 Clamp Meter to measure current on a wire within an electrical panel, showing a reading of 38.7 A.

Voltage-måling (AC/DC)

Til at måle AC eller DC voltage:

  1. Connect the test leads as described in the 'Connecting Test Leads' section.
  2. Turn the function dial to the ∼V (AC voltage) or =V (DC voltage) stilling.
  3. Berør testproberne ved de kredsløbspunkter, hvor vol.tage skal måles.
  4. Læs bindtage -værdi på displayet.

Modstand og kontinuitet

To measure resistance or check continuity:

  1. Connect the test leads.
  2. Turn the function dial to the Ω (resistance/continuity) position.
  3. Touch the test probes across the component or circuit path.
  4. For resistance, read the value on the display. For continuity, the meter will beep if a continuous path is detected.

Frequency, Temperature, and Capacitance

The Fluke 325 also offers specialized measurements:

  • Frekvens (Hz): Select the Hz function to measure the frequency of AC signals.
  • Temperatur (°C/°F): Use the included temperature probe and select the temperature function to measure temperature.
  • Kapacitans: Select the capacitance function to measure the capacitance of components.

True-RMS Accuracy

The True-RMS feature ensures accurate measurements of AC voltage and current, even when waveforms are distorted or non-sinusoidal. This is crucial for modern electrical systems with non-linear loads.

Baggrundsbelyst display

The Fluke 325 features a backlit display for improved visibility in dimly lit environments. Press the backlight button to activate or deactivate the backlight.

Video: Official Fluke overview of the 32X series True-RMS Clamp Meters, highlighting features like compact design, safety ratings, True-RMS accuracy, backlit display, temperature measurements, and DC current measurement (for 325 model).

5. Vedligeholdelse og pleje

Rensning

To clean the meter, wipe it with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.

Udskiftning af batteri

When the battery indicator appears on the display, replace the batteries as described in the 'Battery Installation' section.

Opbevaring

Opbevar måleren et køligt og tørt sted, væk fra direkte sollys og ekstreme temperaturer. Fjern batterierne, hvis den opbevares i længere perioder, for at forhindre lækage.

6. Fejlfinding af almindelige problemer

  • Ingen skærm/strøm: Kontroller batteriinstallationen, og sørg for, at batterierne ikke er afladede.
  • Upræcise læsninger: Verify correct function and range selection. Ensure test leads are properly connected and not damaged. For current measurements, ensure the clamp jaws are fully closed around a single conductor.
  • Continuity Beeper Not Working: Check if the function dial is set to continuity and test leads are making good contact.
  • 'OL' on Display: This indicates an overload or out-of-range measurement. Select a higher range or ensure the measured value is within the meter's specifications.

7. Tekniske specifikationer

SpecifikationVærdi
ModelnummerFLUKE-325
AC strøm400 A
DC-strøm400 A
AC Voltage600 V
DC bindtage600 V
Modstand4 kΩ
FrekvensJa
TemperaturJa
KapacitansJa
SikkerhedsvurderingCAT IV 300 V, CAT III 600 V
Strømkilde2 AA batterier
Varens vægt295 gram (10.41 ounce)
Dimensioner9.45 x 11 x 3.15 tommer

8. Garanti og kundesupport

Fluke products are known for their quality and reliability. For specific warranty details and terms, please refer to the warranty card included with your product or visit the official Fluke website. For technical assistance, troubleshooting, or service, please contact Fluke customer support directly.

Online ressourcer: www.fluke.com

Relaterede dokumenter - FLUKE-325

Preview Fluke 323/324/325 Clamp Brugermanual til måleren - Specifikationer og sikkerhed
Omfattende brugermanual til Fluke 323, 324 og 325 Clamp Målere. Indeholder sikkerhedsoplysninger, elektriske og mekaniske specifikationer og betjeningsvejledninger.
Preview Fluke 323/324/325 Clamp Brugervejledning til måler
Brugermanual til Fluke 323, 324 og 325 True-RMS Clamp Målere, der dækker sikkerhedsoplysninger, specifikationer, drift og vedligeholdelse.
Preview Fluke 323/324/325 Clamp Brugervejledning til måler
Omfattende brugermanual til Fluke 323, 324 og 325 clamp målere, detaljerede funktioner, sikkerhedsforanstaltninger, specifikationer og driftsvejledning til nøjagtige elektriske målinger.
Preview Fluke 381 fjerndisplay True-RMS Clamp Brugervejledning til måler
Omfattende brugermanual til Fluke 381 fjerndisplay True-rms Clamp Måler. Dækker produktfunktioner, måleprocedurer for AC/DC strøm, volumtage, modstand, frekvens, indkoblingsstrøm, vedligeholdelse, specifikationer og sikkerhedsoplysninger. Indeholder detaljerede beskrivelser af diagrammer og tabeller.
Preview Fluke 373 True-RMS AC Clamp Måler - Tekniske specifikationer og deroverview
Detailed technical data, key features, product overview, specifications, and ordering information for the Fluke 373 True-RMS AC Clamp Meter, designed for AC-only current measurements up to 600 A.
Preview Fluke 110 True-RMS multimeter: Tekniske specifikationer og funktioner
Detaljerede specifikationer og funktioner for Fluke 110 kompakte True-RMS multimeter, designet til præcis elektrisk installation og fejlfinding. Inkluderer nøjagtighed, sikkerhedsklassificeringer og medfølgende tilbehør.