Madison M5000

Instruktionsmanual

Madison M5000 væskeniveausensor

Produkt overview

The Madison M5000 is a miniature float switch designed for reliable liquid level detection. Constructed from 316 stainless steel, it is suitable for a wide range of applications, including those requiring superior corrosion resistance, high temperatures, or use in medical, petrochemical, and food processing environments. This sensor detects high or low liquid levels within a container.

Madison M5000 væskeniveausensor

Figur 1: Madison M5000 Liquid Level Sensor. This image shows the stainless steel float switch with its threaded stem and electrical lead wires extending from the top. The main body is cylindrical, designed to float or sink with liquid levels.

Sikkerhedsoplysninger

Before installation and operation, read and understand all instructions. Failure to do so may result in product damage, property damage, or personal injury. Ensure all electrical connections comply with local and national electrical codes. Disconnect power before installing or servicing the sensor.

  • Do not exceed the maximum pressure and temperature ratings of 300 PSI and 392°F (200°C).
  • Ensure the sensor is rated for the specific liquid and environment it will be used in.
  • Afbrydere er klassificeret til ohmske belastninger. Se UL-retningslinjerne for strømstyrke (Amperes resistiv) ved forskellige voltages.

Opsætning og installation

The M5000 sensor is designed for vertical mounting using its 1/8" NPT thread. It can be installed to detect either high or low liquid levels depending on its orientation.

Monteringsretning:

  • Normally Open (NO) Operation: For high-level detection, mount the sensor so the float is at the bottom and rises with the liquid. The switch will close when the liquid reaches the float.
  • Normally Closed (NC) Operation: For low-level detection, mount the sensor so the float is at the top and falls with the liquid. The switch will open when the liquid drops below the float.

Installationstrin:

  1. Identify the desired mounting location in the container, ensuring it is clean and free of debris.
  2. Thread the 1/8" NPT stem into the appropriate port. Use a suitable sealant (e.g., PTFE tape) on the threads to ensure a leak-proof seal. Do not overtighten.
  3. Connect the 24", 22 AWG Teflon insulated lead wires to your control circuit. Refer to the electrical specifications for appropriate voltage og aktuelle vurderinger.
  4. Verify the float moves freely without obstruction within the container.

Driftsprincipper

The Madison M5000 operates on a simple magnetic principle. Inside the stainless steel stem, there is a hermetically sealed reed switch. The float, which contains a magnet, moves along the stem as the liquid level changes. When the magnet in the float comes into proximity with the reed switch, it causes the switch contacts to open or close, signaling the liquid level status to the connected control system.

The float has a specific gravity (SG) of 0.70, meaning it will float in liquids with an SG greater than 0.70. For liquids with an SG less than 0.70, the float will sink, and the sensor's operation will be inverted.

Opretholdelse

The Madison M5000 liquid level sensor is designed for minimal maintenance due to its robust stainless steel construction. However, periodic inspection is recommended to ensure optimal performance.

  • Rensning: If the sensor is used in applications with viscous or particulate-laden liquids, the float and stem may accumulate residue. Periodically clean the float and stem to ensure free movement. Use cleaning agents compatible with 316 stainless steel.
  • Inspektion: Check the lead wires for any signs of damage or wear. Ensure the NPT connection remains secure and leak-free.
  • Funktionstest: If possible, periodically test the sensor's operation by manually raising or lowering the liquid level (or simulating it) to confirm the switch activates correctly.

Fejlfinding

ProblemMulig årsagLøsning
Sensoren aktiveres ikke
  • Forkert ledningsføring
  • Float obstructed or stuck
  • Liquid specific gravity too low
  • Damaged reed switch
  • Verify wiring against electrical diagram.
  • Inspect and clean float/stem for obstructions.
  • Ensure liquid SG is > 0.70 for standard operation.
  • Test switch continuity; replace if faulty.
Intermitterende aflæsninger
  • Løse elektriske forbindelser
  • Vibration
  • Flyder klæber
  • Kontroller og fastgør alle ledningsforbindelser.
  • Ensure stable mounting; consider anti-vibration measures.
  • Clean float and stem.
Leakage at mounting point
  • Improper thread sealant
  • Insufficient tightening
  • Beskadigede gevind
  • Reapply appropriate thread sealant.
  • Tighten connection to recommended torque (without overtightening).
  • Inspect threads for damage; replace sensor or fitting if necessary.

Specifikationer

ParameterVærdi
ModelnummerM5000
Stængelmateriale316 rustfrit stål
Float Materiale316 rustfrit stål
Flydespecifik tyngdekraft (SG)0.70
Monteringsgevind1/8" NPT-gevind
Max tryk300 PSI
Max temperatur392°F (200°C)
Skift vurdering30 watt, SPST (enkeltpolet, enkeltkast)
Elektriske vurderinger
  • 240 VAC, 0.14A
  • 120 VAC, 0.28A
  • 120 VDC, 0.07A
  • 24 VDC, 0.28A
Lead ledninger24", 22 AWG, teflonisoleret
GodkendelserCE, UL, NSF
Produktdimensioner9.06 x 6.3 x 7.09 tommer; 1.6 ounce

Note: Switches are rated for resistive loads. Refer to UL guidelines for current (Amperes resistiv) ved forskellige voltages.

Garantioplysninger

Specific warranty details for the Madison M5000 Liquid Level Sensor are typically provided at the point of purchase or can be obtained directly from Madison Company. Please retain your proof of purchase for warranty claims.

Support og kontakt

For technical assistance, troubleshooting beyond this manual, or inquiries regarding parts and service, please contact Madison Company directly. Contact information can typically be found on the manufacturer's official webwebsted eller produktemballage.

Manufacturer: Madison Company

Relaterede dokumenter - M5000

Preview Madison brugerdefineret trykt informationsguide: Logografik, stolpemåling og farvematchning
Lær hvordan du leverer logo-grafik, måler stolper til specialtryk og matcher farver med Madisons omfattende guide. Vigtig information om specialtrykt sportsudstyr og -tøj.
Preview Madison MAD-MUSICA50 Bluetooth Partyhøjttaler Brugermanual
Oplev funktionerne og betjeningen af ​​Madison MAD-MUSICA50 Bluetooth Party Speaker med denne omfattende brugermanual. Den indeholder detaljerede instruktioner, betjeningsforklaringer og tekniske specifikationer på flere sprog for optimal brug.
Preview Madison FREESOUND-VR40 Vintage Brugervejledning til Bluetooth FM-radio
Omfattende brugermanual til Madison FREESOUND-VR40 vintage-radio, med detaljerede funktioner som Bluetooth, USB-afspilning, FM-radio, sikkerhedsinstruktioner, betjening og specifikationer.
Preview Madison FREESOUND-VR40 genopladelig vintage Radio med Bluetooth, USB og FM-radio 30W brugsanvisning
Brugermanual til Madison FREESOUND-VR40 genopladeligt vintage-radio. Denne enhed har Bluetooth-forbindelse, USB-afspilning, FM-radioindstilling og en AUX-indgang. Manualen indeholder detaljerede sikkerhedsinstruktioner, betjeningsprocedurer for parring, kabelforbindelse, USB-afspilning, valg af tilstand og brug af FM-radio samt tekniske specifikationer og retningslinjer for bortskaffelse.
Preview Madison beskyttende polstring: Skræddersyede løsninger til sport og leg
Madison Sport, en australsk producent siden 1985, leverer skræddersyet beskyttende polstring til sportsklubber, skoler og virksomheder. Vi tilbyder landsdækkende forsendelse, 12 måneders garanti og skræddersyede designs til sikkerhed og leg.
Preview Installationsvejledning til Swiss Madison fritstående linnedskab
Omfattende installationsvejledning til Swiss Madison fritstående linnedskab (model SM-BC51C), der dækker dele, monteringstrin og garantioplysninger. Sørg for korrekt installation ved at følge disse retningslinjer.