Armstrong ovnblæserstyringskredsløb R40403-003 brugsanvisning

Model: R40403-003

Produkt overview

The Armstrong R40403-003 blower control circuit board is designed to replace previous versions R40403-001, R40403-002, and ST9120A, B, or C blower controls. This board manages a 2-speed indoor blower motor and a single-speed inducer motor. It processes inputs from the thermostat (W, Y, and G terminals), pressure switch, and high-temperature limit switches. The control also features user-selectable blower delays via DIP switch settings. A 5-amp replaceable automotive-type fuse protects the 24-volt circuit.

Armstrong R40403-003 Blower Control Circuit Board

Image 1: The Armstrong R40403-003 Blower Control Circuit Board. This image displays the front view of the circuit board, showing various electronic components, relays, terminals, and DIP switches.

Sikkerhedsoplysninger

Always disconnect power to the furnace at the main breaker before attempting any installation, maintenance, or troubleshooting. Failure to do so can result in electrical shock, personal injury, or death. Installation should only be performed by qualified personnel. Ensure all wiring connections comply with local and national electrical codes.

  • Strømafbrydelse: Turn off power at the circuit breaker before handling the board.
  • Statisk udladning: Handle the circuit board by its edges to avoid damage from static electricity.
  • Sikringsbeskyttelse: The 24-volt circuit is protected by a 5-amp automotive-type fuse. Replace only with a fuse of the same rating.

Opsætning og installation

This section provides general guidelines for replacing the Armstrong R40403-003 blower control board. Refer to your furnace's specific wiring diagram for detailed instructions.

  1. Sluk: Ensure all power to the furnace unit is disconnected at the main electrical breaker. Verify with a voltage tester.
  2. Adgang til gammelt opslagstavle: Locate and access the existing blower control board within your furnace.
  3. Dokumentledningsføring: Before disconnecting any wires, take clear photographs of all connections to the old board. Label each wire if necessary.
  4. Frakobl ledninger: Frakobl forsigtigt alle ledninger fra det gamle styrekort.
  5. Fjern gammelt bræt: Skru eller klips det gamle bræt af dets montering.
  6. Monter nyt bræt: Secure the new Armstrong R40403-003 board in the same location using the existing mounting hardware.
  7. Tilslut ledninger: Reconnect all wires to the new board, matching them precisely to the documented connections from the old board. Pay close attention to the transformer leads (C and X terminals). The X lead from the old board typically connects to the XFRMR terminal on the new board.
  8. DIP-switchindstillinger: Adjust the DIP switches on the new board to match the settings of your previous board or according to your furnace's specifications for blower delays.
  9. Undersøg forbindelser: Double-check all wiring connections for security and correctness.
  10. Gendan strøm: Once all connections are verified, restore power to the furnace at the main breaker.
  11. Test drift: Initiate a heating or cooling cycle to confirm proper operation of the furnace and blower.
Armstrong R40403-003 Blower Control Circuit Board Packaging

Image 2: The Armstrong R40403-003 Blower Control Circuit Board in its packaging. This image shows the brown cardboard box with a product label indicating "BLOWER CONTROL" and the model number R40403-003.

Driftsprincipper

The R40403-003 board functions as the central control for the furnace's blower and inducer motors. It receives signals from the thermostat to initiate heating or cooling cycles. The board then activates the appropriate motors and monitors safety limits such as the pressure switch and high-temperature limit switches to ensure safe operation. User-selectable DIP switch settings allow for customization of blower delays, which control how long the blower runs after the heating or cooling call ends, helping to maximize system efficiency and comfort.

Blower Delay Settings

The board features DIP switches to adjust blower delays. Consult your furnace manual or the wiring diagram provided with the board for specific delay settings and their corresponding switch configurations. Typical settings include delays for fan off after heating, and fan on/off for cooling cycles.

Opretholdelse

The Armstrong R40403-003 blower control board is designed for reliable operation and generally requires minimal maintenance. However, periodic checks of the furnace system are recommended.

  • Sikringsinspektion: Periodically inspect the 5-amp automotive-type fuse on the board. If the fuse is blown, replace it only with a fuse of the exact same rating (5 amp). A blown fuse often indicates an underlying electrical issue that should be investigated.
  • Ledningsforbindelser: Annually, or during routine furnace maintenance, inspect all wiring connections to the board to ensure they are secure and free from corrosion.
  • Renhed: Keep the area around the circuit board clean and free from dust and debris, which can impede proper function or lead to overheating.

Fejlfinding

This section provides basic troubleshooting steps for common issues related to the blower control board. For complex problems, consult a qualified HVAC technician.

ProblemMulig årsagLøsning
Furnace not starting / No power to boardBlown fuse on board, tripped circuit breaker, loose wiring connection.Check and replace 5-amp fuse. Reset circuit breaker. Inspect and secure all power connections.
Blæsermotor kører ikkeIncorrect thermostat input, faulty pressure switch, high-limit switch tripped, motor issue, board malfunction.Verify thermostat settings. Check pressure switch and high-limit switch for continuity. Consult HVAC technician for motor or board diagnosis.
Blæser kører kontinuerligtThermostat fan setting "ON", stuck relay on board, incorrect DIP switch setting.Set thermostat fan to "AUTO". Check DIP switch settings for blower delays. If issue persists, board may need replacement.
Inducer motor not runningFaulty inducer motor, pressure switch issue, board malfunction.Check inducer motor for power. Verify pressure switch operation. If necessary, consult a professional.

Specifikationer

Key technical specifications for the Armstrong R40403-003 Blower Control Circuit Board:

  • Modelnummer: R40403-003
  • Replaces Models: R40403-001, R40403-002, 20054502, ST9120A, B, C
  • Driftslinje Voltage: 85 til 135 VAC, 50/60 Hz
  • Secondary Control Voltage: 18.0 til 30.0 VAC, 50/60 Hz
  • Maximum Blower Loading: 15FLA, 30LRA @ 120 VAC; 7.5FLA, 15LRA @ 240 VAC
  • Maximum Inducer Loading: 3FLA, 10LRA @ 120 VAC; 1.5FLA, 5LRA @ 240 VAC
  • Sikringsbeskyttelse: 5 Amp replaceable automotive type fuse (24-volt circuit)
  • Dimensioner: Cirka 7.8 x 6.3 x 3 tommer
  • Vægt: Cirka 0.16 ounce
  • Fabrikant: Armstrong

Garanti og support

Specific warranty information for the Armstrong R40403-003 Blower Control Circuit Board is not provided in this manual. For details regarding warranty coverage, terms, and conditions, please refer to the product packaging or contact Armstrong customer support directly. For technical assistance or professional installation, it is recommended to consult a certified HVAC technician.

You may visit the official Armstrong webwebstedet eller kontakt deres kundeservice for yderligere support.

  • Fabrikant: Armstrong
  • Webwebsted: www.armstrongair.com (General Armstrong HVAC site, as no specific product support link is provided)

Relaterede dokumenter - R40403-003

Preview L83BR1D84/95E16 reservedelsliste og komponentguide
Dette dokument indeholder en omfattende liste over dele til L83BR1D84/95E16-modellen med detaljerede oplysninger om komponentnavne, delnumre og beskrivelser, der hjælper med identifikation og udskiftning.
Preview Armstrong HVAC Tekniske Tips og Servicebulletiner
Samling af tekniske tips og servicebulletiner fra Armstrong Air Conditioning, der dækker forbedringer af tændingsstyring, kontinuerlig blæserdrift, kompressordetaljer, filterdimensionering, ledningsføring, tagkanter og fejlfinding for PGE-, PHP-, PCE- og SHP HVAC-enheder.
Preview Armstrong GFCI Receptacle Installation and Testing Guide
A comprehensive guide for installing and testing Armstrong GFCI receptacles, including wiring instructions, troubleshooting tips, and warranty information.
Preview Montering af Armstrong-lofter overviewEn trin-for-trin guide
Lær hvordan du installerer et Armstrong-loft med denne korte vejledningviewDækker væglister, bjælker, tværprofiler og montering af loftspaneler til boligbrug. Har QuickHang™-beslag.
Preview Monterings- og driftsvejledning til Armstrong E.2-seriens højeffektive cirkulator
Omfattende installations- og betjeningsvejledning til Armstrong E.2-seriens højeffektive cirkulationspumpe, der dækker driftsgrænser, elektrisk ledningsføring, opstartsprocedurer, vedligeholdelse, udskiftning af pumpe og udskiftning af mekaniske tætninger.
Preview WoodWorks® monteringsvejledning til skjulte lister | Armstrong
Omfattende installationsvejledning til Armstrongs WoodWorks® skjulte loftlister. Lær, hvordan du korrekt installerer denne arkitektoniske loftlister til WoodWorks® skjulte og lineære finerede paneler.