The KING HWP120 is an advanced electronic line voltage programmable thermostat designed specifically for hydronic heating systems. This thermostat offers precise temperature control and energy savings through its 7-day independent programming capabilities, allowing for up to four time and temperature settings per day. Its user-friendly design features an illuminated LCD display and simple two-button operation for setting temperature and navigating menus. The HWP120 is equipped with memory backup to retain settings during power outages, ensuring consistent comfort.

Figur 1: Vinklet view of the KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat, showing its white casing and green illuminated LCD display.
Sikkerhedsoplysninger
ADVARSEL: To prevent electric shock or damage to the thermostat, disconnect power to the heating system at the main fuse or circuit breaker box before installation or servicing. This thermostat operates on line voltage (120V/240V) and requires careful handling. Installation should only be performed by a qualified electrician in accordance with local electrical codes.
- Always turn off power at the circuit breaker before working with electrical wiring.
- Sørg for, at alle ledningsforbindelser er sikre og korrekt isolerede.
- Do not exceed the specified electrical ratings of the thermostat (12.5 amps / 120 volts, 3000 watts / 240 volts).
- Keep the thermostat away from water and excessive humidity.
Installation og opsætning
Proper installation is crucial for the safe and efficient operation of your HWP120 thermostat. It is recommended that a licensed electrician perform the installation.
Monteringssted
Choose a location on an interior wall, approximately 5 feet (1.5 meters) above the floor, away from direct sunlight, drafts, or heat sources (e.g., lamps, appliances, fireplaces). These factors can affect the thermostat's temperature readings.
Ledningsinstruktioner
- Afbryd strømmen: Turn off the power to your heating system at the main circuit breaker. Verify power is off before proceeding.
- Fjern gammel termostat: Fjern forsigtigt din eksisterende termostat fra væggen. Bemærk ledningsforbindelserne.
- Tilslut ledninger: Connect the wires from your heating system to the appropriate terminals on the HWP120 thermostat. Refer to the wiring diagram provided with your thermostat's packaging for specific connections. Ensure all connections are tight.
- Monter termostat: Secure the HWP120 thermostat to the wall using the provided mounting screws.
- Gendan strøm: Når installationen er færdig, og alle forbindelser er sikre, skal strømmen genoprettes ved afbryderen.

Figur 2: Forside view of the KING HWP120 Thermostat, highlighting the LCD display and the two control buttons below it.
Betjeningsvejledning
The HWP120 thermostat is designed for straightforward operation using its two primary buttons and illuminated LCD display.
Display overview
The LCD display shows the current room temperature, the set temperature, the time, day of the week, and the active program period (P1, P2, P3, P4). When the heating system is active, a "HEAT" indicator will typically be visible.

Figur 3: Sidevinklet view of the KING HWP120 Thermostat, showing the ventilation grilles on the side and the clear display.
Adjusting Temperature Manually
To temporarily adjust the temperature, press the Up (▲) eller Ned (▼) buttons. The display will show the new set temperature. This manual override will typically remain active until the next programmed period begins.
Indstilling af tid og dag
Refer to the detailed programming section for initial setup of time and day, as these are integral to the programming functions.
Programmeringsinstruktioner
The HWP120 allows for 7 independent day programming with 4 times and temperature settings (P1, P2, P3, P4) per day. This feature helps optimize energy consumption by adjusting heating based on your schedule.
Går ind i programmeringstilstand
To enter programming mode, press and hold both the Up (▲) og Ned (▼) buttons simultaneously for a few seconds until the display changes to indicate programming mode (e.g., flashing time or day).
Indstilling af tid og dag
- In programming mode, the hour will typically flash. Use the Up or Ned knapper for at justere timen.
- Press one of the buttons (e.g., Up or Ned, depending on the model's specific navigation) to advance to minutes, then adjust.
- Continue to advance to set the day of the week.
Setting Program Periods (P1-P4)
For each day of the week, you can set four distinct periods:
- P1 (Wake): Typically for morning, when you wake up.
- P2 (Leave): For when you leave home.
- P3 (Return): For when you return home.
- P4 (Sleep): For nighttime.
- While in programming mode, navigate to the desired day (e.g., Monday).
- Select P1. Set the desired start time and temperature for P1 using the Up or Ned knapper.
- Advance to P2 and repeat the process for its start time and temperature.
- Continue for P3 and P4.
- Repeat this process for each day of the week (Tuesday through Sunday).
- Afslutter programmeringstilstand: Once all settings are complete, the thermostat will typically exit programming mode automatically after a period of inactivity, or you may need to press and hold the buttons again to save and exit. Consult the full manual for specific exit procedures.
Vigtig bemærkning: The HWP120 thermostat initiates heating at the programmed time to reach the set temperature. It does not anticipate heating. Therefore, if you desire a room to be at a specific temperature by a certain time, set the program to begin heating approximately 15-30 minutes prior to that desired time, depending on your system's response time.
Opretholdelse
The KING HWP120 thermostat requires minimal maintenance to ensure optimal performance.
- Rensning: Tør termostatens yderside regelmæssigt af med en blød klud.amp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or internal components.
- Fjernelse af støv: Ensure the ventilation slots on the thermostat casing remain clear of dust and debris to allow for proper air circulation and accurate temperature sensing.
- Power Outage: The thermostat features memory backup for power outages, retaining your programmed settings. No action is typically required after a power restoration.
Fejlfinding
If you encounter issues with your HWP120 thermostat, refer to the following common problems and solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Termostatdisplayet er tomt. | Ingen strøm til termostaten. | Check the circuit breaker for your heating system. Ensure it is in the "ON" position. Verify wiring connections. |
| Heating system not turning on/off as programmed. | Incorrect programming; manual override active; system malfunction. | Review your program settings carefully. Ensure no manual override is active. Check your heating system for other issues. |
| Room temperature inaccurate. | Termostatens placering påvirkes af træk eller varmekilder. | Ensure the thermostat is not exposed to direct sunlight, drafts from windows/doors, or heat from appliances. |
| Vanskeligheder med programmering. | Unfamiliarity with programming sequence. | Carefully re-read the "Programming Instructions" section. Practice the steps without making permanent changes. |
If problems persist after attempting these solutions, contact a qualified electrician or KING customer support for assistance.
Specifikationer
| Feature | Detalje |
|---|---|
| Modelnavn | HWP120 |
| Mærke | KONGE |
| Voltage | 120 volt / 240 volt |
| Ampslette | 12.5 amps (120V) / 12.5 amps (240V) |
| Wattage | 1500 watts (120V) / 3000 watts (240V) |
| Temperaturområde | 44°F til 95°F (7°C til 35°C) |
| Nøjagtighed | ± 1.2°F @ 10 amps, ± .9°F @ 4.2 amps |
| Programmering | 7 independent day programming with 4 times and temperature settings per day |
| Display Type | Digital, Illuminated LCD |
| Kontroltype | Tryk knap |
| Materiale | Plast |
| Dimensioner (L x B x H) | 4.88 x 3.13 x 2 tommer |
| Varens vægt | 10.4 ounce |
Garanti og support
Garantioplysninger
The KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat comes with a 1 års begrænset garanti from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the warranty documentation included with your product or visit the manufacturer's official webwebsted.
Kundesupport
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact KING customer support. You can typically find contact information (phone number, email, or support portal) on the manufacturer's webwebsted eller i produktemballagen.