KING HWP120

KING HWP120 Elektronisk Linjevolumentage Programmable Hydronic System Thermostat

Model: HWP120

Indledning

The KING HWP120 is an advanced electronic line voltage programmable thermostat designed specifically for hydronic heating systems. This thermostat offers precise temperature control and energy savings through its 7-day independent programming capabilities, allowing for up to four time and temperature settings per day. Its user-friendly design features an illuminated LCD display and simple two-button operation for setting temperature and navigating menus. The HWP120 is equipped with memory backup to retain settings during power outages, ensuring consistent comfort.

KING HWP120 Thermostat angled view

Figur 1: Vinklet view of the KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat, showing its white casing and green illuminated LCD display.

Sikkerhedsoplysninger

ADVARSEL: To prevent electric shock or damage to the thermostat, disconnect power to the heating system at the main fuse or circuit breaker box before installation or servicing. This thermostat operates on line voltage (120V/240V) and requires careful handling. Installation should only be performed by a qualified electrician in accordance with local electrical codes.

Installation og opsætning

Proper installation is crucial for the safe and efficient operation of your HWP120 thermostat. It is recommended that a licensed electrician perform the installation.

Monteringssted

Choose a location on an interior wall, approximately 5 feet (1.5 meters) above the floor, away from direct sunlight, drafts, or heat sources (e.g., lamps, appliances, fireplaces). These factors can affect the thermostat's temperature readings.

Ledningsinstruktioner

  1. Afbryd strømmen: Turn off the power to your heating system at the main circuit breaker. Verify power is off before proceeding.
  2. Fjern gammel termostat: Fjern forsigtigt din eksisterende termostat fra væggen. Bemærk ledningsforbindelserne.
  3. Tilslut ledninger: Connect the wires from your heating system to the appropriate terminals on the HWP120 thermostat. Refer to the wiring diagram provided with your thermostat's packaging for specific connections. Ensure all connections are tight.
  4. Monter termostat: Secure the HWP120 thermostat to the wall using the provided mounting screws.
  5. Gendan strøm: Når installationen er færdig, og alle forbindelser er sikre, skal strømmen genoprettes ved afbryderen.
Front view of KING HWP120 Thermostat

Figur 2: Forside view of the KING HWP120 Thermostat, highlighting the LCD display and the two control buttons below it.

Betjeningsvejledning

The HWP120 thermostat is designed for straightforward operation using its two primary buttons and illuminated LCD display.

Display overview

The LCD display shows the current room temperature, the set temperature, the time, day of the week, and the active program period (P1, P2, P3, P4). When the heating system is active, a "HEAT" indicator will typically be visible.

Sidevinklet view of KING HWP120 Thermostat

Figur 3: Sidevinklet view of the KING HWP120 Thermostat, showing the ventilation grilles on the side and the clear display.

Adjusting Temperature Manually

To temporarily adjust the temperature, press the Up () eller Ned () buttons. The display will show the new set temperature. This manual override will typically remain active until the next programmed period begins.

Indstilling af tid og dag

Refer to the detailed programming section for initial setup of time and day, as these are integral to the programming functions.

Programmeringsinstruktioner

The HWP120 allows for 7 independent day programming with 4 times and temperature settings (P1, P2, P3, P4) per day. This feature helps optimize energy consumption by adjusting heating based on your schedule.

Går ind i programmeringstilstand

To enter programming mode, press and hold both the Up () og Ned () buttons simultaneously for a few seconds until the display changes to indicate programming mode (e.g., flashing time or day).

Indstilling af tid og dag

  1. In programming mode, the hour will typically flash. Use the Up or Ned knapper for at justere timen.
  2. Press one of the buttons (e.g., Up or Ned, depending on the model's specific navigation) to advance to minutes, then adjust.
  3. Continue to advance to set the day of the week.

Setting Program Periods (P1-P4)

For each day of the week, you can set four distinct periods:

  1. While in programming mode, navigate to the desired day (e.g., Monday).
  2. Select P1. Set the desired start time and temperature for P1 using the Up or Ned knapper.
  3. Advance to P2 and repeat the process for its start time and temperature.
  4. Continue for P3 and P4.
  5. Repeat this process for each day of the week (Tuesday through Sunday).
  6. Afslutter programmeringstilstand: Once all settings are complete, the thermostat will typically exit programming mode automatically after a period of inactivity, or you may need to press and hold the buttons again to save and exit. Consult the full manual for specific exit procedures.

Vigtig bemærkning: The HWP120 thermostat initiates heating at the programmed time to reach the set temperature. It does not anticipate heating. Therefore, if you desire a room to be at a specific temperature by a certain time, set the program to begin heating approximately 15-30 minutes prior to that desired time, depending on your system's response time.

Opretholdelse

The KING HWP120 thermostat requires minimal maintenance to ensure optimal performance.

Fejlfinding

If you encounter issues with your HWP120 thermostat, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Termostatdisplayet er tomt.Ingen strøm til termostaten.Check the circuit breaker for your heating system. Ensure it is in the "ON" position. Verify wiring connections.
Heating system not turning on/off as programmed.Incorrect programming; manual override active; system malfunction.Review your program settings carefully. Ensure no manual override is active. Check your heating system for other issues.
Room temperature inaccurate.Termostatens placering påvirkes af træk eller varmekilder.Ensure the thermostat is not exposed to direct sunlight, drafts from windows/doors, or heat from appliances.
Vanskeligheder med programmering.Unfamiliarity with programming sequence.Carefully re-read the "Programming Instructions" section. Practice the steps without making permanent changes.

If problems persist after attempting these solutions, contact a qualified electrician or KING customer support for assistance.

Specifikationer

FeatureDetalje
ModelnavnHWP120
MærkeKONGE
Voltage120 volt / 240 volt
Ampslette12.5 amps (120V) / 12.5 amps (240V)
Wattage1500 watts (120V) / 3000 watts (240V)
Temperaturområde44°F til 95°F (7°C til 35°C)
Nøjagtighed± 1.2°F @ 10 amps, ± .9°F @ 4.2 amps
Programmering7 independent day programming with 4 times and temperature settings per day
Display TypeDigital, Illuminated LCD
KontroltypeTryk knap
MaterialePlast
Dimensioner (L x B x H)4.88 x 3.13 x 2 tommer
Varens vægt10.4 ounce

Garanti og support

Garantioplysninger

The KING HWP120 Electronic Line Voltage Programmable Hydronic System Thermostat comes with a 1 års begrænset garanti from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms and conditions, please refer to the warranty documentation included with your product or visit the manufacturer's official webwebsted.

Kundesupport

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact KING customer support. You can typically find contact information (phone number, email, or support portal) on the manufacturer's webwebsted eller i produktemballagen.

It is recommended to have your product model number (HWP120) and date of purchase available when contacting support.

Relaterede dokumenter - HWP120

Preview King H-seriens vandbaserede vægvarmere: Installationsvejledning og specifikationer
Omfattende installationsvejledning, sikkerhedsadvarsler, monteringsvejledninger, ledningsdiagrammer og produktspecifikationer for King H-seriens hydroniske vægvarmere. Indeholder modeloplysninger, BTU-klassificeringer og termostatkompatibilitet.
Preview King KRF-HEAT-KIT trådløs 24V RF termostatsæt til elektrisk varmestyring
Omfattende guide til King KRF-HEAT-KIT, et trådløst 24V RF-termostatsystem designet til netvolumen.tage elektrisk varmestyring. Funktionerne omfatter den programmerbare KRFTP-B termostat og KRFLR-120/240V relæet, med detaljerede specifikationer, bestillingsoplysninger og valgfrit tilbehør for forbedret styring og energibesparelser.
Preview King Electric termostater og styringskatalog
Omfattende katalog over King Electrics linjevolumentage og lav voltage-termostater, programmerbare og ikke-programmerbare modeller, inklusive ATMOZ WIFI, Clear Touch, SIMPLSTAT, ES, ESP, WR, HP, K101, K102, K101-C, EP3, TF115, HW, HWP, HWPT, HB, HBP, F912GFCI, F902GFCI, CWR IceFree, SnowFree, PYRO og FPC-serien. Funktionerne omfatter energibesparelse, avanceret sensorering og smart home-integration.
Preview Installations-, ledningsførings- og programmeringsvejledning til King HW-FS-, HWP-FS- og HWPT-FS-termostater i 120V-serien
Omfattende vejledning til King Electrics termostater i HW-FS-, HWP-FS- og HWPT-FS 120V-serien. Dækker generelle oplysninger, sikkerhed, specifikationer, ledningsføringsinstruktioner, programmering til HWP/HWPT-modeller, installation og vedligeholdelse. Indeholder detaljer om temperaturstyring til varmesystemer til private og erhvervsejendomme.
Preview King trådløst 24V RF termostatsæt KRF-24V-KIT til HVAC-systemer
Information om King Wireless 24V RF-termostatsættet (KRF-24V-KIT), der inkluderer KRFTP-B-termostaten og KRFR-24V HVAC-relæet. Detaljerne omfatter trådløs kommunikation, programmering og valgfrit tilbehør til forbedret HVAC-styring.
Preview Installations- og vedligeholdelsesvejledning til King LPW-ECO-serien af ​​varmeapparat
Omfattende vejledning til installation, drift og vedligeholdelse af elektroniske varmeapparater i King LPW-ECO-serien, inklusive sikkerhedsinstruktioner, ledningsdiagrammer, opsætning af fjernsensorer og fejlfinding.