1. Introduktion

The Johnson Controls MR4PMUHV-12C Defrost Control is engineered for use in refrigeration and freezer units, supporting both hot gas and electric heat defrost methods. This control unit offers flexible defrost termination options, allowing selection between time-based or temperature-based methods. It integrates essential control functions including compressor management, defrost cycle management, fan operation control, and alarm management, providing a comprehensive solution for HVAC systems.

Johnson Controls MR4PMUHV-12C Defrost Control unit with two coiled temperature sensors

Figur 1: Johnson Controls MR4PMUHV-12C Defrost Control unit and included temperature sensors. The central gray unit features a digital display and control buttons, while two coiled gray cables with metallic tips represent the temperature sensors.

2. Hvad er der i æsken

3. Nøglefunktioner

4. Opsætning og installation

Proper installation is crucial for the safe and efficient operation of the defrost control. Always ensure power is disconnected before beginning any installation or wiring procedures.

  1. Sikkerhed først: Disconnect all power to the refrigeration or freezer unit before proceeding. Follow all local electrical codes and safety guidelines.
  2. Montering: Select a suitable location for mounting the control unit and, if applicable, the separate relay pack. Ensure adequate ventilation and protection from moisture. The flexible design allows for combined or separate mounting.
  3. Ledningsforbindelser:
    • Connect the 24VAC power supply to the designated terminals on the control unit.
    • Wire the compressor, fans, and defrost heaters to the heavy-duty relay terminals as per the wiring diagram provided with the product.
    • Connect any external alarm systems to the dedicated alarm terminals.
  4. Sensor installation: Install the temperature sensors in the appropriate locations within the evaporator or process area as required for accurate temperature monitoring. Ensure sensor cables are routed safely and securely.
  5. Indledende opstart: Once all connections are secure and verified, restore power to the unit. The control unit display should illuminate.

5. Betjening

After successful installation, the MR4PMUHV-12C is ready for configuration and operation.

  1. Display overview: Upon power-up, the digital display will show the current temperature. Pressing the designated button (refer to product-specific labeling) allows toggling between evaporator and process temperature readings.
  2. Setting Defrost Parameters: Access the control unit's menu (typically via dedicated buttons) to configure defrost settings. This includes:
    • Afrimningsinterval: Set the frequency at which defrost cycles occur.
    • Defrost Duration: Specify the maximum time for a defrost cycle.
    • Defrost Termination Method: Choose between time-based termination (defrost ends after a set duration) or temperature-based termination (defrost ends when a specific temperature is reached).
    • Fan Delay: Configure any fan delay settings post-defrost.
  3. Alarmindstillinger: Configure temperature thresholds for alarms to ensure optimal operating conditions and prompt notification of deviations.
  4. Overvågning: Regularly check the display for current temperatures and system status.

6. Vedligeholdelse

Routine maintenance helps ensure the longevity and reliable performance of your defrost control unit.

7. Fejlfinding

Dette afsnit indeholder vejledning til almindelige problemer. Kontakt kvalificeret servicepersonale ved komplekse problemer.

8. Specifikationer

ModelnummerMR4PMUHV-12C
Produktdimensioner10.5 x 5.5 x 6.5 tommer
Varens vægt3.17 Pounds (3.2 Pounds listed elsewhere)
MærkeJohnson kontrol
MaterialePlast
Driftstemperatur32 grader Fahrenheit (0°C)
FabrikantJohnson Controls Inc

9. Garanti og support

For information regarding product warranty, technical support, or service, please contact Johnson Controls directly or refer to the official documentation included with your purchase. Keep your proof of purchase for warranty claims.

Johnson Controls Contact Information: Please visit the official Johnson Controls webwebstedet for de seneste kontaktoplysninger og supportressourcer.

Relaterede dokumenter - MR4PMUHV-12C

Preview Installationsvejledning til Johnson Controls A421-serien af ​​elektroniske temperaturregulatorer med off-cycle afrimning
Omfattende installationsvejledning til Johnson Controls PENN A421-seriens elektroniske temperaturregulatorer med off-cycle afrimningsfunktion. Dækker produkt overview, anvendelser, dimensioner, montering, ledningsføring, opsætning, justeringer, fejlfinding og tekniske specifikationer.
Preview A419-seriens elektroniske temperaturregulatorer med display og NEMA 1- eller NEMA 4X vandtætte kabinetter
Denne tekniske bulletin fra Johnson Controls beskriver A419-serien af ​​elektroniske temperaturregulatorer, der er designet til enkeltspolede temperaturstyringer.tagKøle- og HVAC-applikationer. Den dækker funktioner, fordele, NEMA 1- og NEMA 4X-kapslingsmuligheder, betjening, ledningsføring, justeringer, fejlfinding, fejlkoder, bestillingsoplysninger og tekniske specifikationer.
Preview Johnson Controls A19 Series Remote Bulb Control - Temperature Sensors
Detailed specifications and selection guide for Johnson Controls A19 Series remote bulb temperature controls, used in HVAC, heating, ventilating, and refrigeration applications. Includes model numbers, electrical ratings, and features.
Preview PENN A19-seriens fjernbetjening til pære, katalogside | Johnson Controls
Katalogside for PENN A19-seriens fjernbetjeninger til pærer, med enkelt-stage temperaturregulatorer med væskefyldte følerelementer. Indeholder udvalgstabeller, tekniske specifikationer, reservedele og kontaktoplysninger.
Preview Brugervejledning til Hx 3-berøringsskærmstermostat
Denne brugermanual indeholder detaljerede instruktioner og vejledning til Johnson Controls Hx 3 touchskærmstermostaten (model: S1-THXU430W), der dækker installation, funktioner, betjening, app-tilslutning og indstillinger.
Preview Installationsvejledning til udskiftning af intermitterende pilottændingskontroller i G600-serien
Omfattende installations-, monterings-, ledningsførings-, opsætnings-, betjenings- og fejlfindingsvejledning til Johnson Controls G600-seriens udskiftningsstyring af intermitterende pilottænding.