Indledning
The Fluke 62 Max is a robust and reliable industrial infrared thermometer designed for non-contact surface temperature measurement. It is engineered to withstand harsh industrial environments, featuring an IP54 rating for dust and water resistance and a durable design capable of withstanding a 3-meter drop. This device is ideal for monitoring electrical, mechanical, HVAC, and automotive systems.
Vigtig bemærkning: This product is intended for industrial use only and is not designed or approved for measuring human body temperature.
Sikkerhedsoplysninger
Before operating the Fluke 62 Max, please read and understand all safety warnings and operating instructions. Failure to do so may result in injury or damage to the product.
- This thermometer is for industrial applications only. Do not use it for medical purposes or to measure human body temperature.
- Do not point the laser directly at eyes or indirectly off reflective surfaces.
- Exercise caution when measuring hot surfaces. The thermometer measures surface temperature, but objects may have internal temperatures significantly higher or lower.
- Do not use the thermometer in explosive gas, vapor, or dust environments.
- Ensure the battery compartment is securely closed before use, especially in dusty or wet environments.
Produktegenskaber
The Fluke 62 Max offers a range of features designed for industrial reliability and precision:
- Non-contact surface temperature measurement.
- Temperature range: -30 to 500 degrees C (-22 to 932 degrees F).
- Accuracy: ±1.5 degrees C or ±1.5 percent of the reading (from 0 to 500 degrees C).
- 10:1 distance to spot ratio with single laser targeting for precise measurement area identification.
- IP54 rated for protection against dust and splashing liquid.
- Rugged design capable of withstanding a 3-meter (9.8 foot) drop.
- Displays minimum, maximum, difference (MAX-MIN), and average temperatures.
- Adjustable emissivity for improved accuracy on various surfaces.
- High and low alarms to alert users to temperatures outside a set range.
- Large, backlit display for easy data readability in various lighting conditions.
- Kompakt og let design til bærbarhed.
Komponenter og hvad der er i æsken
The Fluke 62 Max package typically includes the following:
- Fluke 62 Max Industrial Infrared Thermometer
- 1 AA-batteri (forinstalleret eller medfølger separat)

Figur 1: Forside view of the Fluke 62 Max Industrial Infrared Thermometer, showing the display, buttons, and laser aperture.
Opsætning
Installation af batteri
- Locate the battery compartment cover, typically on the handle of the thermometer.
- Åbn batterirummet.
- Isæt et AA-batteri, og sørg for at polariteten (+ og -) vender korrekt.
- Luk batterirummets dæksel forsvarligt.
Tænd/sluk
The thermometer powers on automatically when the measurement trigger is pressed. It will power off automatically after a period of inactivity to conserve battery life.
Betjeningsvejledning
At tage en måling
- Ret termometeret mod målobjektet.
- Press and hold the measurement trigger. The laser will activate, indicating the center of the measurement area.
- Temperaturaflæsningen vil vises på displayet.
- Release the trigger to hold the reading on the display. The thermometer will automatically turn off after a period of inactivity.

Figure 2: User holding the Fluke 62 Max, aiming it at an electrical panel to take a temperature reading.
Afstand til punktforhold (D:S)
The Fluke 62 Max has a 10:1 D:S ratio. This means that at a distance of 10 units from the target, the measurement spot diameter will be 1 unit. For example, if you are 10 inches away from the target, the measurement spot will be 1 inch in diameter. To ensure accurate readings, make sure the target area is larger than the spot size.
Justering af emissionsevne
Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. For accurate measurements, adjust the thermometer's emissivity setting to match the material being measured. Refer to the thermometer's display for the current emissivity setting (e.g., "EMS 0.95"). Consult a standard emissivity table for common materials.
Min/Max/Avg/Diff Modes
The thermometer can display various statistical temperature readings:
- MIN: Displays the minimum temperature recorded during a continuous measurement.
- MAKS: Displays the maximum temperature recorded during a continuous measurement.
- AVG: Displays the average temperature recorded during a continuous measurement.
- DIF: Displays the difference between the maximum and minimum temperatures recorded.
Use the "SEL" button to cycle through these display modes.

Figure 3: An industrial worker utilizing the Fluke 62 Max from an elevated platform to inspect the temperature of overhead ductwork, demonstrating its application in HVAC systems.

Figure 4: A technician using the Fluke 62 Max to check the temperature of a bearing on large industrial machinery, highlighting its use in mechanical system monitoring.
Opretholdelse
Rengøring af termometeret
To maintain the accuracy and longevity of your Fluke 62 Max, keep the lens and the unit clean. The product care instructions specify "Wipe Clean".
- Brug en blød, damp cloth with mild soap and water to clean the casing. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- For the lens, use a soft cloth or cotton swab with water or medical alcohol. Do not scratch the lens.
Udskiftning af batteri
When the low battery indicator appears on the display, replace the AA battery as described in the "Setup" section.
Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| No display/Unit does not power on | Dødt eller forkert installeret batteri. | Udskift batteriet, og sørg for korrekt polaritet. |
| Unøjagtige aflæsninger | Incorrect emissivity setting; target too small; lens dirty; outside operating temperature range. | Adjust emissivity; ensure target is larger than spot size; clean lens; operate within specified temperature range. |
| Laser ikke synlig | Laser disabled (if applicable); bright ambient light; laser malfunction. | Check settings; move to a less brightly lit area; contact support if persistent. |
Specifikationer
| Specifikation | Værdi |
|---|---|
| Modelnummer | 62MAX |
| Temperaturområde | -30 til 500 °C (-22 til 932 °F) |
| Accuracy (0 to 500 °C) | ±1.5 °C or ±1.5% of reading |
| Afstand til punktforhold (D:S) | 10:1 |
| Ingress Protection (IP) Rating | IP54 (dust and splashing liquid resistant) |
| Faldtestvurdering | 3 meter (9.8 fod) |
| Strømkilde | 1 AA batteri (medfølger) |
| Produktdimensioner | 9.5 x 7.75 x 3 tommer; 8.99 ounce |
| Display Type | Digital, Baggrundsbelyst |
| Forbindelsesteknologi | Infrarød |
| Fabrikant | Fluke Corporation |
Garanti og support
Garantioplysninger
The Fluke 62 Max Industrial Infrared Thermometer includes a 3-year warranty from the manufacturer, Fluke Corporation. Please retain your proof of purchase for warranty claims.
For detailed warranty terms and conditions, please refer to the official Fluke documentation or visit the Fluke webwebsted.
Kundesupport
For technical assistance, service, or repair, please contact Fluke customer support. Contact information can typically be found on the official Fluke webwebsted eller i produktemballagen.
Du kan besøge Fluke-butik på Amazon for mere produktinformation og ressourcer.