Gewiss GW10592 (Chorus)

Gewiss GW10592 Infrared Motion Detector

Brugermanual

Model: GW10592 (Chorus)

1. Introduktion

This user manual provides detailed instructions for the installation, operation, and maintenance of the Gewiss GW10592 Infrared Motion Detector. This device is designed to detect movement within its specified range and can be integrated into various security or automation systems. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Sikkerhedsoplysninger

ADVARSEL: Risiko for elektrisk stød!

Installation and wiring of this device must be performed by a qualified electrician in accordance with all local and national electrical codes. Ensure the main power supply is disconnected before commencing any installation or maintenance work.

  • Udsæt ikke enheden for fugt eller ekstreme temperaturer.
  • Forsøg ikke at åbne eller reparere enheden selv. Overlad al service til kvalificeret personale.
  • Sørg for korrekt jordforbindelse, hvor det er nødvendigt.

3. Pakkens indhold

Tjek venligst pakken for følgende varer:

  • Gewiss GW10592 Infrared Motion Detector Unit
  • Brugervejledning (dette dokument)
  • Mounting Screws and Wall Plugs (may vary by package)

4. Produktet er slutview og funktioner

The Gewiss GW10592 is a compact infrared motion detector designed for indoor use. It features a passive infrared (PIR) sensor that detects changes in infrared radiation caused by moving objects, such as people. The device is suitable for integration into lighting control systems, alarm systems, or other automation applications.

Front view of the Gewiss GW10592 Infrared Motion Detector, showing the white casing, dark grey sensor lens, and two adjustment knobs labeled LUX and TIME.

Figur 1: Forside view of the Gewiss GW10592 Infrared Motion Detector. The device has a white square casing with a prominent dark grey circular sensor lens in the center. Above the lens, two small dark grey adjustment knobs are visible, labeled "LUX" and "TIME" respectively, indicating controls for light sensitivity and detection duration.

Nøglefunktioner:

  • Infrared (PIR) motion detection
  • Wired power supply (230V)
  • Compact design for discreet installation
  • Adjustable LUX (light sensitivity) and TIME (detection duration) settings
  • Maximum detection range of 2 meters

5. Opsætning og installation

Before installation, ensure the power supply to the circuit is completely turned off at the main breaker. This device is designed for flush-mounted installation within a standard electrical box.

5.1 Ledningsdiagram

Refer to the wiring diagram provided on the device itself or within the packaging for correct connection. Typically, the device will require Live (L), Neutral (N), and a Switched Live (L') output to control the connected load (e.g., light fixture).

  • Connect the Live wire from the power supply to the 'L' terminal.
  • Connect the Neutral wire from the power supply to the 'N' terminal.
  • Connect the Live wire of the load (e.g., light) to the 'L'' terminal.
  • Sørg for, at alle forbindelser er sikre og isolerede.

Note: Incorrect wiring can damage the device or cause electrical hazards. If you are unsure, consult a qualified electrician.

5.2 Montering

  1. Prepare the electrical box in the desired installation location.
  2. Carefully insert the wired motion detector into the electrical box.
  3. Secure the device using the provided mounting screws.
  4. Attach the faceplate (if separate) to complete the installation.

Vælg et monteringssted, der giver en uhindret view of the area to be monitored and is free from direct heat sources or air currents that could cause false triggers.

6. Betjeningsvejledning

Once installed and powered on, the Gewiss GW10592 motion detector will begin its operation. The device features two adjustable knobs for fine-tuning its performance:

  • LUX (lysfølsomhed): This knob controls the ambient light level at which the detector becomes active.
    • Vend dig mod solikon for the detector to operate during both day and night (high light sensitivity).
    • Vend dig mod måneikon for the detector to operate only in low light conditions or darkness (low light sensitivity).
  • TID (Detektionsvarighed): This knob sets the duration for which the connected load (e.g., light) remains active after motion is detected and no further motion is sensed.
    • Vend dig mod minus (-) symbol for a shorter duration.
    • Vend dig mod plus (+) symbol for a longer duration.

After adjusting the settings, allow a brief stabilization period (typically 30-60 seconds) for the detector to calibrate.

7. Vedligeholdelse

The Gewiss GW10592 motion detector requires minimal maintenance. Follow these guidelines:

  • Rensning: Gently wipe the sensor lens and casing with a soft, dry, lint-free cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.
  • Inspektion: Periodically check for any visible damage to the casing or wiring. If damage is observed, disconnect power and consult a qualified electrician.
  • Der er ingen dele inde i denne enhed, der kan repareres af brugeren.

8. Fejlfinding

If you experience issues with your Gewiss GW10592 motion detector, refer to the following common problems and solutions:

ProblemMulig årsagLøsning
Device not detecting motion.No power; incorrect wiring; sensor obstructed; incorrect LUX setting.Check power supply and wiring. Ensure sensor lens is clean and unobstructed. Adjust LUX setting to operate in current light conditions.
Connected load (e.g., light) stays on constantly.Continuous motion in detection area; faulty wiring; internal fault.Ensure no constant motion. Check wiring for short circuits. If problem persists, consult a qualified electrician.
Connected load turns on/off too frequently (false triggers).Heat sources (HVAC vents, direct sunlight); pets; incorrect sensitivity.Relocate device away from heat sources. Adjust TIME setting. Ensure pets are not triggering the sensor.
Connected load does not turn off.TIME setting too long; continuous motion; faulty relay.Adjust TIME setting to a shorter duration. Ensure no continuous motion. If problem persists, consult a qualified electrician.

For issues not listed above, or if troubleshooting steps do not resolve the problem, please contact Gewiss customer support or a qualified electrician.

9. Specifikationer

AttributVærdi
FabrikantGewiss
ModelnummerGW10592 (Chorus)
DetektionsteknologiInfrarød (PIR)
StrømkildeKablet
Voltage230 volt
Maksimal rækkevidde2 meter
FarveWhite (with Black/Dark Grey sensor)
Varens vægt80 g
Emballeringsmål6.86 x 5.33 x 5.08 cm

10. Garanti og support

For information regarding warranty coverage, technical support, or spare parts, please contact Gewiss customer service directly. Retain your proof of purchase for warranty claims.

You can typically find contact information on the official Gewiss webwebstedet eller på produktemballagen.

Relaterede dokumenter - GW10592 (Chorus)

Preview Joinon Wallbox ICon Basic hurtig installationsvejledning
En kortfattet vejledning til hurtig installation af Joinon Wallbox I-Con Basic ladestation til elbiler fra Gewiss.
Preview GEWISS GWA9181 KNX Sikker 4-kanals Kontaktgrænseflade Teknisk manual
Detaljeret teknisk manual til GEWISS GWA9181 KNX Secure 4-kanals kontaktgrænseflade, der dækker installation, konfiguration, parametre og kommunikationsobjekter til smart home- og bygningsautomationssystemer.
Preview JOINON WALLBOX I-CON BASIC Quick Installation Guide
This document provides a quick installation guide for the JOINON WALLBOX I-CON BASIC electric vehicle charging station by GEWISS. It details the steps for mounting the unit, connecting the power supply, and ensuring proper installation.
Preview GEWISS CHORUSMART CVD 4X10A DIN-skinne LED-dæmper - Tekniske specifikationer
Detaljerede tekniske specifikationer og installationsvejledning til GEWISS CHORUSMART CVD 4X10A DIN-skinneforstærkeren, der er designet til at udvide LED-dæmperens styrekapacitet.
Preview Installations- og betjeningsvejledning til Gewiss ChorusSmart Connected Axial 2-kommandomodul
Dette dokument indeholder detaljerede oplysninger om Gewiss ChorusSmart Connected Axial 2-Command Module, herunder installation, funktioner, tekniske data og fejlfinding. Det understøtter ZigBee-kommunikation til smart home-automation.
Preview GEWISS JOINON WALLBOX I-CON BASIC Hurtig installationsvejledning
Trin-for-trin installationsvejledning til GEWISS JOINON WALLBOX I-CON BASIC ladestation til elbiler, med detaljerede oplysninger om montering og elektrisk tilslutning.