Indledning
This user manual provides comprehensive information for the DB Electrical SND0559 Starter. It is designed to assist with understanding the product's specifications, compatibility, installation procedures, and general maintenance. This starter is an aftermarket replacement component engineered to meet OEM specifications for various heavy-duty and commercial vehicles.
Sikkerhedsoplysninger
Always prioritize safety when working with automotive electrical systems. Failure to follow proper safety procedures can result in serious injury or damage to the vehicle.
- Disconnect the vehicle's battery before beginning any work on the electrical system.
- Brug passende personlige værnemidler (PPE), herunder sikkerhedsbriller og handsker.
- Sørg for, at køretøjet er sikkert understøttet på donkrafte, hvis du arbejder under det.
- Kontakt en professionel mekaniker, hvis du er usikker på nogen af installationstrinnene.
- Hold alt værktøj og arbejdsområder rene og fri for snavs.
Specifikationer
The DB Electrical SND0559 Starter is built to precise specifications to ensure optimal performance and compatibility.
| Attribut | Værdi |
|---|---|
| Enhedstype | Starter |
| Voltage | 12 volt |
| Rotation | CW (med uret) |
| Tænder | 10 |
| KW | 5.0 |
| Starttype | OSGR |
| Varemodelnummer | 410-52166 |
| Varens vægt | 25.2 pund |
| Produktdimensioner | 14.63 x 9.5 x 6.5 tommer |
| UPC | 701485532979 |
Erstatter OEM-numre: ARROWHEAD: SND0559, ARROWHEAD (OEM): NDTG428000-4430, DENSO: 428000-4430, TG428000-4430, INTL HARVESTER: 2593563C91, J & N: 410-52166, LESTER: 19502.
Kompatibilitet
This starter is compatible with a wide range of heavy-duty and commercial vehicles. Please verify your vehicle's specific requirements before purchasing og installation.
- FREIGHTLINER: Argosy (2000-2003), C112 Century Class (1996-2000), C120 Century Class (1996-2007), Classic (1994-2007), Columbia (2001-2007), Coronado (2003-2007), FL 106 (1999-2003), FL FLC 112 / 120 (1994-2003), FLD 112 / 120 (1993-2007)
- INTERNATIONAL: 5000-5900 Series Severe Service (1993-1999), 8100-8600 Heavy-Duty (1992-2000), 9100-9900 Heavy-Duty (1992-2003)
- KENWORTH: C500 (1993-1994), K100 (1993-1995), T2000 (1997-1999), T400 / T450 (1993-1996), T600 / T800 (1993-2003), W900 (1993-1997)
- MACK: CH Series (1988-2007), CL Series (1990-2007), CT / CTP Series (2006-2007), CV Series (2001-2007), CX Series (Vision) (2000-2005), DM / DMM Series (1984-2007), F / FL / FS Series (1984-1988), FDM Series (1988-1999), Granite Series (2002-2007), MC Series (1984-1994), MH Series (1984-1994), MR Series (1984-2007), R Series (1984-1990), RB Series (1988-2007), RD Series (1984-2007), RL Series (1984-1990), RM Series (1984-1994), RS Series (1984-1990), RW Series (1984-1994), U Series (1984-1985)
- PETERBILT: 320 (1993-1999), 357 (1993-1999), 362 (1993-1999), 375 (1993-1999), 377 (1993-2000), 378 (1993-1999), 379 (1993-1999), 385 (1996-1999)
- STERLING: A-Line A9500 / AT9500 (1999-2007), L-Line 7500 / 8000 / 8500 / 9500 (1999-2007), Silver Star Series (1999-2001)
- VOLVO: ACL42 / ACL64 Series (1996-2000), VNL Series (1996-2003), VNM Series (1997-2003), WA / WC / WG / WH / WI / WX Series (1996-2003)
- WESTERN STAR: All Models (By Engine) (1994-1998)
Installation (Opsætning)
Proper installation is crucial for the longevity and performance of your new starter. These are general guidelines; always refer to your vehicle's specific service manual for detailed instructions.
- Forberedelse:
- Sørg for, at køretøjet er parkeret på en plan overflade, og at parkeringsbremsen er aktiveret.
- Disconnect the negative battery cable first, then the positive battery cable.
- If necessary, lift the vehicle using a hydraulic jack and secure it with jack stands.
- Fjern den gamle starter:
- Locate the starter motor. It is typically mounted on the engine block near the transmission.
- Disconnect the electrical connections from the old starter (battery cable, solenoid wire). Note their positions for reinstallation.
- Remove the mounting bolts securing the starter to the engine/transmission.
- Carefully remove the old starter from the vehicle.
- Installer ny starter:
- Compare the new DB Electrical SND0559 starter with the old unit to ensure they match in size, mounting points, and electrical connections.
- Position the new starter in place and hand-tighten the mounting bolts.
- Tighten the mounting bolts to the manufacturer's specified torque settings.
- Reconnect the electrical connections to the new starter. Ensure all connections are clean and secure.
- Sidste trin:
- Tilslut det positive batterikabel igen, og derefter det negative batterikabel.
- Lower the vehicle if it was lifted.
- Test the starter by attempting to start the vehicle.

Figur 1: Forside view of the DB Electrical SND0559 Starter, highlighting the gear and mounting flange.

Figur 2: Side view of the starter, illustrating the electrical terminals and the solenoid assembly.
Operation
The starter motor is an electric motor that rotates the engine's flywheel to initiate the combustion process. When the ignition key is turned to the "start" position, electrical current flows to the starter solenoid, which engages the starter drive gear with the engine's flywheel and simultaneously sends power to the starter motor. Once the engine starts, the starter drive disengages from the flywheel, and the starter motor ceases operation.
Opretholdelse
Starters are generally low-maintenance components. However, regular checks can help ensure their longevity and reliable operation.
- Batteriets sundhed: Ensure your vehicle's battery is in good condition and fully charged. A weak battery can put excessive strain on the starter.
- Elektriske forbindelser: Periodically inspect all electrical connections to the starter for corrosion or looseness. Clean and tighten as necessary.
- Monteringssikkerhed: Check that the starter mounting bolts are secure and properly torqued.
- Undgå overdreven omdrejning: Do not crank the engine for extended periods (more than 10-15 seconds) without a pause. This can overheat the starter. Allow a minute or two between attempts.
Fejlfinding
If you experience issues with your starter, consider the following common problems and their potential solutions:
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Starter clicks but engine does not crank | Weak battery, loose battery cables, faulty solenoid, seized engine | Check battery charge and terminals. Inspect battery cables for corrosion. Test solenoid. Consult mechanic for engine issues. |
| Starteren drejer langsomt | Low battery charge, corroded battery terminals, high resistance in starter circuit | Charge/replace battery. Clean battery terminals. Inspect and clean all starter circuit connections. |
| Starter does not engage (no click, no crank) | Blown fuse, faulty ignition switch, open circuit in starter wiring, faulty starter motor | Check fuses. Test ignition switch. Inspect wiring for breaks. Test starter motor. |
| Slibende lyd under tørning | Damaged starter drive gear, damaged flywheel teeth, improper starter alignment | Inspect starter drive and flywheel. Re-align or replace starter. Professional inspection recommended. |
If these troubleshooting steps do not resolve the issue, it is recommended to consult a qualified automotive technician.
Garanti og support
DB Electrical stands behind the quality of its products. This starter comes with a 1 års garanti fra købsdatoen.
Garantidækning: The warranty covers defects in materials and workmanship under normal use. If the product fails due to a manufacturing defect within one year of purchase, DB Electrical will replace it.
Sådan får du støtte: If you encounter any issues with your DB Electrical SND0559 Starter or need to claim warranty service, please contact DB Electrical customer support directly. Have your purchase details and the product's model number ready for faster assistance.
For further assistance or inquiries, please visit the official DB Electrical webwebsted eller kontakt deres kundeserviceafdeling.