AmScope B490 Compound Binocular Microscope Instruction Manual

Model: B490

1. Produktet er slutview

The AmScope B490 is a compound binocular microscope designed for biological and educational applications, offering high magnification and clear imaging. It features a sliding head for adjustable interpupillary distance, 10x widefield eyepieces, and a forward-facing nosepiece with four DIN achromatic objectives (4x, 10x, 40xS, 100xS oil). Illumination is provided by Brightfield halogen light with a rheostat for intensity control, paired with a 1.25 NA Abbe condenser and iris diaphragm. The microscope includes a double-layer mechanical stage med astage stop and graduated coarse and fine focus with tension control.

AmScope B490 Compound Binocular Microscope

Figure 1: AmScope B490 Compound Binocular Microscope, front-side view.

Inkluderede komponenter:

  • AmScope B490 microscope with double-layer mechanical stage
  • 10x widefield eyepieces (one pair)
  • 4x DIN achromatic objective
  • 10x DIN achromatic objective
  • 40xS DIN achromatic objective
  • 100xS (oil) DIN achromatic objective
  • Immersion oil (one bottle)
  • Color filters (blue and green)
  • Spare halogen bulb
  • Reserve sikring
  • Brugsanvisning
AmScope B490 Microscope Accessories

Figure 2: Included accessories: eyepieces, objectives, immersion oil, color filters, spare bulb, and fuse.

2. Opsætningsvejledning

  1. Udpakning: Carefully remove all components from the packaging. Retain the original packaging for future transport or storage.
  2. Placering: Place the microscope on a stable, level surface away from direct sunlight, excessive heat, dust, and vibrations.
  3. Hovedsamling: Loosen the head retaining screw on the microscope body. Gently insert the binocular head into the top opening, ensuring it is fully seated. Tighten the retaining screw to secure the head.
  4. Eyepiece Installation: Remove the protective caps from the eyepiece tubes and the eyepieces. Insert the two WF10x eyepieces into the binocular head's eyepiece tubes.
  5. Objective Installation: Rotate the revolving nosepiece until the 4x objective is positioned over the stage opening. Install the remaining objectives (10x, 40xS, 100xS oil) clockwise into the nosepiece.
  6. Strømtilslutning: Ensure the power switch is in the 'OFF' position. Connect the power cord to the microscope's power input and then to a suitable electrical outlet (110V).
AmScope B490 Microscope Side View

Figur 3: Side view of the microscope, showing focus knobs and power input location.

3. Betjeningsvejledning

3.1 Power and Illumination

  1. Turn on the main power switch located on the base of the microscope.
  2. Adjust the illumination intensity using the rheostat knob on the side of the base. Start with a lower intensity and increase as needed for comfortable viewing.

3.2 Specimen Placement

  1. Rotate the revolving nosepiece to select the lowest power objective (4x).
  2. Hæv stage using the coarse focus knob to create enough space to place the specimen slide.
  3. Åbn stage clips on the mechanical stage and carefully place the specimen slide, securing it with the clips.
  4. Brug XY stage control knobs to position the desired area of the specimen directly under the objective lens.
AmScope B490 Microscope Front View

Figur 4: Forside view of the microscope, highlighting the mechanical stage and objectives.

3.3 Focusing and Magnification

  1. Interpupillær afstand: While looking through the eyepieces, adjust the sliding head to match your eye distance until a single, circular field of view is observed. The range is 55 to 75mm.
  2. Dioptrisk justering: If one eye is stronger than the other, use the diopter adjustment ring on one eyepiece to compensate, ensuring both eyes are in focus.
  3. Grov fokus: Slowly lower the stage using the coarse focus knob until the specimen comes into rough focus.
  4. Fin fokus: Use the fine focus knob for precise focusing and to achieve a sharp image.
  5. Ændring af mål: To increase magnification, rotate the revolving nosepiece clockwise to the next objective (e.g., from 4x to 10x). Due to the parfocal design, only minor fine focus adjustments should be needed.
  6. Using 100xS Oil Immersion Objective: When using the 100xS objective, apply a small drop of immersion oil directly onto the specimen slide in the area to be viewed. Carefully lower the 100xS objective into the oil drop until it makes contact. Focus using the fine focus knob only. Always clean the 100xS objective and slide immediately after use to prevent oil from drying.
AmScope B490 Objectives and Stage Close-up

Figur 5: Nærbillede view of the objectives and mechanical stage.

3.4 Condenser and Iris Diaphragm Adjustment

  1. The 1.25 NA Abbe condenser is mounted on a rack-and-pinion system, allowing its height to be adjusted. Raise or lower the condenser to optimize illumination for different objectives.
  2. The iris diaphragm lever controls the aperture of the light beam. Adjust it to achieve optimal contrast and resolution for the specimen and objective in use. Generally, a smaller aperture increases contrast but reduces resolution, while a larger aperture increases resolution but reduces contrast.

4. Vedligeholdelse

4.1 Rengøring

  • Optical Components: Use only specialized lens cleaning paper and lens cleaning solution. Gently wipe lenses in a circular motion. Avoid touching optical surfaces with bare hands.
  • Legeme: Clean the microscope body with a soft, damp klæde. Undgå at bruge skrappe kemikalier eller opløsningsmidler.
  • Immersionsolie: After using the 100xS oil immersion objective, immediately clean the objective lens and the specimen slide with lens cleaning solution to prevent oil residue from hardening.

4.2 Udskiftning af pære

If the halogen illumination fails, the bulb may need replacement. Ensure the microscope is unplugged and the bulb has cooled before attempting replacement. Refer to the diagram in the original packaging for specific bulb access. Use the provided spare halogen bulb (6V/20W).

4.3 Udskiftning af sikringer

If the microscope does not power on, check the fuse. Ensure the microscope is unplugged. The fuse holder is typically located near the power input. Replace with the provided spare fuse of the correct rating.

4.4 Opbevaring

When not in use, cover the microscope with a dust cover to protect it from dust and debris. Store in a cool, dry place. The anti-mold surfaces help preserve optics in high-humidity environments, but proper storage is still recommended.

5. Fejlfinding

ProblemMulig årsagLøsning
Ingen belysningPower cord disconnected, power switch off, bulb burnt out, fuse blownCheck power connection, turn on switch, replace bulb, replace fuse
Billedet er sløret/ude af fokusIncorrect focus, objective not fully engaged, dirty lenses, incorrect interpupillary distance/diopter settingAdjust coarse/fine focus, rotate nosepiece until objective clicks into place, clean lenses, adjust interpupillary distance/diopter
Insufficient contrastIris diaphragm too open, condenser height incorrectAdjust iris diaphragm to a smaller aperture, adjust condenser height
Mørke pletter i marken viewDust on eyepieces or objectives, dirty specimen slideClean eyepieces, objectives, and specimen slide
Stage not moving smoothlyStage lock engaged, debris in mechanismSørg for stage lock is disengaged, clean stage area (consult professional if persistent)

6. Specifikationer

FeatureSpecifikation
HovedCompound Binocular, Sliding Head, 30-degree inclination, 360-degree rotation
OkularerWF10x
Mål4x, 10x, 40xS (spring), 100xS (spring, oil) DIN Achromatic
Forstørrelsesområde40X-1000X
StageDouble-layer Mechanical Stage (140 x 140mm), 75 x 45mm traveling range, 1mm divisions, Stage Stop
FokuseringCoaxial Coarse and Fine Focus, 30mm focusing range, 0.002mm fine-focus divisions, Tension Control
BelysningTransmitted (lower) Brightfield Halogen with Rheostat (6V/20W)
Kondensator1.25 NA Abbe Condenser with Iris Diaphragm, Rack-and-Pinion Control
Interpupillær afstand55-75 mm
Magt110V (US standard)
Dimensioner (H x B x D)16 x 9 x 12 tommer (ca.)
Vægt15.32 pund (omtrentligt)
MaterialeSolid-metal enamel-coated body, optical glass components
Særlige funktionerAnti-mold surfaces

7. Garanti og support

For warranty information, technical support, or service inquiries, please refer to the official AmScope website or contact AmScope customer service directly. Details regarding specific warranty periods and support procedures are typically provided with your purchase documentation or on the manufacturer's official channels.

Manufacturer: AmScope

Headquarters: Irvine, CA, USA

Relaterede dokumenter - B490

Preview Brugermanual til AmScope 120-seriens mikroskop
Omfattende brugermanual til AmScope 120-serien af ​​mikroskoper (B120 og T120), der dækker opsætning, betjening, specifikationer og fejlfinding.
Preview AmScope 490-seriens sammensatte mikroskop brugermanual
Denne brugermanual indeholder omfattende instruktioner til AmScope 490-serien af ​​sammensatte mikroskoper, der dækker opsætning, betjening, vedligeholdelse og fejlfinding for optimal brug.
Preview AmScope 490-seriens sammensatte mikroskop brugermanual | Brugervejledning
This operator's manual provides comprehensive instructions for the AmScope 490 Series Compound Microscope, covering setup, operation, maintenance, troubleshooting, and specifications. Learn to use your AmScope microscope effectively with this detailed guide.
Preview Brugermanual til AmScope PM240-seriens stereomikroskop
Brugermanual til AmScope PM240-serien af ​​stereomikroskoper, der dækker opsætning, betjening, specifikationer og fejlfinding for binokulære og trinokulære modeller.
Preview Brugermanual til AmScope 120-seriens mikroskop
Omfattende brugermanual til AmScope 120-serien af ​​mikroskoper, der dækker opsætning, betjening, specifikationer og fejlfinding for modeller som B120 og T120.
Preview Brugermanual til AmScope M150-seriens mikroskop
Brugermanual til AmScope M150-serien af ​​mikroskoper, der dækker opsætning, betjening, vedligeholdelse, specifikationer og fejlfinding.