Pittsburgh 2.5 CFM 1/6 HP One Stage Vakuumpumpe

Pittsburgh 2.5 CFM 1/6 HP One Stage Brugervejledning til vakuumpumpe

Model: 2.5 CFM 1/6 HP One Stage Vakuumpumpe

Indledning

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump. Please read this manual thoroughly before operating the pump and retain it for future reference.

The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump is designed for deeper vacuum draw, pulling vacuum down to 75 microns. Its precision-machined one-stage pump effectively removes moisture from air conditioning systems, preparing them for safe refrigerant addition. This pump is ideal for automotive air conditioning, HVAC work, and other applications requiring high vacuum pull from a compact unit.

Vigtige sikkerhedsoplysninger

Always observe basic safety precautions when using this product to reduce the risk of personal injury and damage to equipment.

  • Læs alle instruktioner før brug.
  • Brug passende personlige værnemidler (PPE), herunder sikkerhedsbriller og handsker.
  • Sørg for, at arbejdsområdet er godt ventileret.
  • Brug ikke pumpen i våde forhold, og udsæt den ikke for regn.
  • Afbryd strømmen, før du udfører vedligeholdelse eller service.
  • Use only with specified refrigerants (R134A, R12, R22).

Opsætning

Before initial operation, ensure the vacuum pump is placed on a stable, level surface. Check the oil level and fill if necessary with appropriate vacuum pump oil.

Initial Oil Fill/Check

  1. Locate the oil fill cap and sight glass on the pump.
  2. Unscrew the oil fill cap.
  3. Pour vacuum pump oil into the fill port until the oil level is visible in the sight glass, reaching the indicated fill line. Do not overfill.
  4. Sæt oliepåfyldningsdækslet ordentligt på.

Connecting to an HVAC System

The pump features dual ports for R134A and R12/R22 systems. Use appropriate manifold gauges and hoses for connection.

Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump connected to an HVAC system with manifold gauges.

Figur 1: The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump connected to an HVAC system. The image shows the vacuum pump on a wooden deck, connected via yellow and blue hoses to a manifold gauge set. The manifold gauge set is then connected to an outdoor HVAC unit. This setup illustrates a typical vacuuming process for an air conditioning system.

  1. Ensure all valves on the manifold gauge set are closed.
  2. Connect the appropriate vacuum hose from the manifold gauge set to the vacuum pump's inlet port.
  3. Connect the manifold gauge set to the service ports of the HVAC system.
  4. Kontroller, at alle forbindelser er tætte for at forhindre lækager.

Betjeningsvejledning

Follow these steps for proper operation of the vacuum pump to evacuate an HVAC system.

  1. With the pump connected to the system and manifold gauges, open the manifold gauge valves to the system.
  2. Plug the vacuum pump into a grounded electrical outlet.
  3. Turn on the vacuum pump. The pump will begin to pull a vacuum on the system.
  4. Monitor the vacuum gauge on your manifold set. Allow the pump to run until the desired vacuum level (e.g., 75 microns or lower) is achieved and held steady for a specified period (e.g., 15-30 minutes) to ensure all moisture is removed.
  5. Once the desired vacuum is reached, close the manifold gauge valves to isolate the system from the pump.
  6. Turn off the vacuum pump and then disconnect it from the manifold gauges.
  7. Proceed with refrigerant charging as per HVAC system manufacturer's instructions.

Opretholdelse

Regular maintenance ensures the longevity and optimal performance of your vacuum pump.

Olieskift

Vacuum pump oil should be changed frequently, especially after each use on a contaminated system or when the oil appears cloudy or discolored. Contaminated oil reduces the pump's ability to pull a deep vacuum.

  1. Ensure the pump is off and unplugged.
  2. Placer en passende beholder under olieaftapningsproppen.
  3. Fjern olieaftapningsproppen, og lad al gammel olie løbe helt ud.
  4. Replace the oil drain plug securely.
  5. Refill with new, clean vacuum pump oil as described in the "Initial Oil Fill/Check" section.

Generel rengøring

Keep the exterior of the pump clean and free of debris. Do not use harsh chemicals or solvents that could damage the housing.

Fejlfinding

Dette afsnit omhandler almindelige problemer, du kan støde på med din vakuumpumpe.

ProblemMulig årsagLøsning
Pumpen starter ikkeNo power; Thermal overload tripped; Motor fault.Check power connection and outlet; Allow pump to cool down; Consult qualified technician.
Pump not pulling sufficient vacuumLow or contaminated oil; Leaks in system/hoses; Clogged inlet filter.Change oil; Check all connections for leaks; Clean/replace inlet filter.
Overdreven støj/vibrationLow oil level; Damaged internal components.Check and add oil; Contact customer support for service.

Specifikationer

Key technical specifications for the Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump:

  • Anvendelse: R134A, R12, R22 refrigerant
  • Flowhastighed: 2.5 CFM
  • Horsepower (hp): 1 / 6 HP
  • Maksimal vakuum: 75 mikron (10 Pascal)
  • Produkthøjde: 9 tommer.
  • Produktlængde: 11-1/4 tommer.
  • Produktbredde: 4-3/4 tommer.
  • Vægt: 18.25 lb.
  • Trådstørrelse: 1/4 in. SAE & 1/2 in.
  • Husmateriale: Durable die cast aluminum
  • Beskyttelse: Thermal and current overload protection

Garanti og support

For garantioplysninger eller teknisk support henvises til producentens officielle webwebstedet eller kontakt deres kundeserviceafdeling. Gem din købskvittering til garantikrav.

Fabrikant: Pittsburgh

ASIN: B006ZBAXSW

Dato først tilgængelig: 4. maj 2014

For yderligere hjælp kan du besøge product page on Amazon.com.

Relaterede dokumenter - 2.5 CFM 1/6 HK One Stage Vakuumpumpe

Preview Pittsburgh A/C Manifold Gauge Set Owner's Manual & Safety Instructions
This manual provides safety instructions, specifications, applications, operation, and maintenance for the Pittsburgh A/C Manifold Gauge Set. It details how to safely use the gauge set for automotive air conditioning systems, including procedures for diagnostic checks, recovery/evacuation, and charging.
Preview Brugermanual og sikkerhedsinstruktioner til Pittsburgh Double Flaring-værktøjssæt
Denne manual indeholder sikkerhedsadvarsler, monterings-, betjenings-, inspektions-, vedligeholdelses- og rengøringsprocedurer for Pittsburgh Double Flaring Tool Kit. Den indeholder specifikationer, vigtige sikkerhedsoplysninger, betjeningsvejledninger, retningslinjer for vedligeholdelse og service samt en liste over dele og et diagram.
Preview PITTSBURGH 6" digital kompositskydelære brugermanual og sikkerhedsinstruktioner
Denne manual indeholder sikkerhedsadvarsler, forholdsregler, monterings-, betjenings-, inspektions-, vedligeholdelses- og rengøringsprocedurer for PITTSBURGH 6" komposit digital skydelære. Den indeholder vigtige sikkerhedsoplysninger, komponentbeskrivelser, betjeningsvejledninger og garantioplysninger.
Preview Pittsburgh Dual Power Home 120V/Auto 12V Dækpumpe med LED-lys - Brugermanual og sikkerhedsinstruktioner
Omfattende brugermanual og sikkerhedsinstruktioner til Pittsburgh Dual Power Home 120V/Auto 12V dækpumpe med LED-lys. Dækker oplysninger om betjening, vedligeholdelse, fejlfinding og garanti.
Preview Pittsburgh 8" trekæbede aftrækker brugermanual og sikkerhedsinstruktioner
Brugermanual og sikkerhedsinstruktioner til Pittsburgh 8-tommer aftrækker med tre kæber (model 63952). Indeholder oplysninger om opsætning, montering, betjening, vedligeholdelse, reservedelsliste og garanti fra Harbor Freight Tools.
Preview Pittsburgh hydraulisk donkraft: Vigtige instruktioner før brug
Læs disse vigtige instruktioner før brug af hydrauliske donkrafte fra Pittsburgh for at sikre sikker og korrekt brug. Indeholder kontaktoplysninger til teknisk support.