1. Introduktion
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Airflow Icon 15S Low Voltage Extractor Fan. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
The Airflow Icon 15S is a low voltage (12V DC) axial extractor fan designed for effective ventilation in domestic environments, including bathrooms and cloakrooms. It features a 100mm (4 inch) outlet and an iris shutter mechanism that opens when the fan is active and closes when off, preventing back draughts. The fan can be mounted either on a surface or recessed into a wall or ceiling and operates via a 12V DC transformer. Various optional control modules are available to enhance its functionality.
2. Sikkerhedsoplysninger
WARNING: Electrical installation should only be performed by a qualified electrician in accordance with local wiring regulations.
- Always disconnect the power supply before installation, maintenance, or servicing.
- Ensure the fan is correctly earthed if required by local regulations.
- Do not install the fan where it may be exposed to direct water spray or excessive humidity beyond its IPX4 rating.
- Keep children and unauthorized persons away from the installation area.
- Sørg for, at alle ledningsforbindelser er sikre og korrekt isolerede.
- Do not obstruct the fan's airflow during operation.
- Dette apparat er ikke beregnet til brug af personer (inklusive børn) med nedsatte fysiske, sensoriske eller mentale evner, eller mangel på erfaring og viden, medmindre de har fået opsyn eller instruktion i brugen af apparatet af en person, der er ansvarlig for deres sikkerhed.
3. Produktet er slutview
The Airflow Icon 15S features a sleek design with an integrated iris shutter. The fan is designed for discreet integration into various room decors.

Figur 3.1: Front view of the Airflow Icon 15S fan with the iris shutter closed, showing the smooth, unobtrusive design and the 'AIRFLOW iCON' logo.

Figur 3.2: Front view of the Airflow Icon 15S fan with the iris shutter open, revealing the internal fan blades and grille for ventilation.

Figur 3.3: Side profile view of the Airflow Icon 15S fan, illustrating its compact depth and the duct connection point.
4. Specifikationer
Detailed technical specifications for the Airflow Icon 15S fan are provided below. For a visual representation of dimensions and other data, refer to Figure 4.1.
| Feature | Specifikation |
|---|---|
| Mærke | Luftstrøm |
| Modelnavn | iCON 15S |
| Elektrisk ventilator design | Udstødningsventilator |
| Strømkilde | Corded Electric (12V DC Transformer) |
| Værelsestype | Bathroom, Cloakroom |
| Særlige funktioner | Remote Controlled (with optional module), Water Resistant (IPX4), Timer (with optional module), Silent Operation |
| Anbefalede anvendelser | Ventilation |
| Støjniveau | 32.4 decibel |
| Wattage | 6.1 watts (Fan only), 7.5 watts (Total consumption) |
| Luftmængde kapacitet | 79 Cubic Meters Per Hour (21.9 Liters Per Second) |
| Voltage | 12 volt (DC) |
| Varens vægt | 1.13 kilo (2.48 pund) |
| Inkluderede komponenter | Cord (for transformer connection) |
| Indendørs/Udendørs brug | Indendørs |
| Specifikation Met | CE |
| Installationstype | Wall Mount, Ceiling Mount (Surface or Recessed) |
| Produktdimensioner | 4.27 x 7.76 x 7.76 tommer (108.5 x 197 x 197 mm) |
| Ingress Protection Rating | IPX4 |
| Maks. Omgivelsestemperatur | 40 °C |

Figur 4.1: Consolidated technical data for the Airflow Icon 15S, including specifications, available cover colors, detailed dimensions (in mm), and a static pressure vs. airflow performance graph.
5. Installation
Installation should be carried out by a qualified professional. Ensure the power supply is disconnected before commencing work.

Figur 5.1: Diagrams illustrating various installation methods for the Airflow Icon 15S, including recessed and surface mounting on walls and ceilings, along with best practice recommendations for flexible ducting.
5.1 Væginstallation
Forsænket vægmontering
- The iCON 15S requires a 110mm diameter hole through the wall.
- The hole should be lined with a 100mm internal diameter duct.
- Secure the fan within the prepared opening using appropriate fixings.
Overflade vægmontering
- When surface mounting, use the supplied mounting skirt.
- The iCON 15S requires a 100mm internal diameter duct for connection.
- Ensure all vapor barriers are properly restored after installation.
5.2 Loftsinstallation
Forsænket loftmontering
- iCON 15S kræver et hul på 110 mm i diameter gennem loftet.
- The fan should be fitted into the hole and fixed with screws provided into the support structure.
Overflademontering i loft
- When surface mounting, use the supplied mounting skirt.
- The fan is then fitted into the skirt and secured.
- For recessed or surface mounting in a ceiling, a plywood support (min. 18mm thick) must be mounted between the ceiling joists. Any fixing screws should be fitted through the plasterboard into the support.
5.3 Ducting Recommendations
- Where flexible ducting is used, the diameter must be maintained.
- It is good ventilation practice that the ducting is extended to a minimum of 90% its possible length in order to maintain the best possible airflow.
- Ensure that flexible duct connections are not overtightened to the spigots.
- To maximize airflow, rigid ducting should be used where possible.
- Fan and ducting installation must comply with the requirements of the Domestic Ventilation Compliance Guide and relevant Building Regulations.
6. Betjeningsvejledning
The basic Airflow Icon 15S fan operates when power is supplied to its 12V DC transformer, typically controlled by a remote switch (e.g., a light switch). For advanced functionalities, optional plug-in modules are required.
6.1 Grundlæggende betjening
- When the fan receives power, the iris shutter will open, and the fan will begin to extract air.
- When power is removed, the fan will stop, and the iris shutter will close, preventing back draughts.
6.2 Operation with Optional Modules
Refer to Section 8, "Optional Modules," for details on specific module functionalities such as pull cord, timer, humidity sensor, and PIR motion detection.
7. Vedligeholdelse
Regular cleaning and maintenance will ensure the longevity and efficient operation of your Airflow Icon 15S fan. Always disconnect the power supply before performing any maintenance.
- Rengøring af ydersiden: Tør det ydre afasing med en blød, damp klæde. Brug ikke slibende rengøringsmidler eller opløsningsmidler.
- Cleaning the Iris Shutter and Blades: Carefully open the iris shutter (if possible, or remove the cover as per installation instructions) and gently clean any dust or debris from the shutter mechanism and fan blades using a soft brush or cloth. Ensure no foreign objects obstruct the shutter's movement.
- Inspektion: Periodically check for any signs of damage to the casing, wiring, or fan components. If any damage is found, consult a qualified technician.
- Do not lubricate any part of the fan.
8. Valgfrie moduler
The Airflow Icon 15S fan can be enhanced with various plug-in modules to provide additional control features. These modules are sold separately and are quick and easy to install.

Figur 8.1: Table detailing available optional modules for the iCON SELV 12V series, including their part numbers and descriptions, as well as optional cover colors for iCON 15S and iCON 30S models.
Available iCON SELV 12V Optional Modules:
| Del nr. | Model | Beskrivelse |
|---|---|---|
| 72573603 | PCS | Træk ledning (manuel tænd/sluk) |
| 72574204 | PCTS | Træk ledningstimer (Kør på timer 1-30 min) |
| 72682307 | DTS | Forsinket timer (2 min forsinkelse, Kør på timer 2-45 min, træk i ledningen) |
| 72574202 | HTS | Fugtighedstimer (40-90 % RF, Kør på timer 2-45 min, træk i ledningen) |
| 72574203 | PRTS | PIR timer (Bevægelsessensor, Kør på timer 2-45 min) |
| 72574201 | PRHTS | PIR with humidity timer (Motion sensor, 40-90% RH, Run on timer) |
9. Fejlfinding
If you encounter issues with your Airflow Icon 15S fan, refer to the table below for common problems and their potential solutions. Always disconnect power before inspecting the unit.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Ventilatoren fungerer ikke | No power supply; Faulty wiring; Faulty transformer; Faulty module (if installed). | Check power supply at the switch; Verify wiring connections; Test transformer output; Replace module if necessary. Consult a qualified electrician. |
| Iris shutter does not open/close properly | Obstruction by dust/debris; Mechanical fault in shutter mechanism. | Disconnect power and carefully clean the shutter and surrounding area; If problem persists, contact support. |
| Reduced airflow/poor extraction | Obstructed ducting; Dirty fan blades; Incorrect ducting installation. | Check ducting for blockages or kinks; Clean fan blades; Ensure ducting meets installation guidelines (e.g., correct diameter, minimal bends). |
| Overdreven støj under drift | Loose mounting; Obstruction in fan blades; Motor issue. | Ensure fan is securely mounted; Disconnect power and check for debris in blades; If motor noise, contact support. |
10. Garantioplysninger
The Airflow Icon 15S Low Voltage Extractor Fan is typically supplied with a 3 års garanti from the date of purchase, covering manufacturing defects. This warranty does not cover damage resulting from improper installation, misuse, neglect, unauthorized repairs, or normal wear and tear.
Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided at the time of purchase or contact Airflow customer support.
11. Kundesupport
For technical assistance, spare parts, or warranty inquiries, please contact Airflow customer support. Ensure you have your product model (iCON 15S) and proof of purchase available when contacting support.
Airflow Contact Information:
Please refer to the official Airflow webwebstedet eller din produktemballage for at få de seneste kontaktoplysninger.