1. Introduktion
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Einhell BT-AC 230/24 Compressor. Please read this manual thoroughly before using the product and keep it for future reference.
2. Sikkerhedsinstruktioner
Always adhere to general safety regulations when operating electrical equipment. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.
- Sørg for, at kompressoren er placeret på en stabil, plan overflade.
- Brug ikke kompressoren i damp eller våde forhold.
- Always wear appropriate personal protective equipment, including eye and ear protection.
- Before any maintenance or adjustment, disconnect the compressor from the power supply and ensure all pressure is released.
- Ret ikke trykluft mod mennesker eller dyr.
- Regularly check hoses and connections for damage or leaks.
3. Produktfunktioner
The Einhell BT-AC 230/24 Compressor is designed for various compressed air applications. Key features include:
- Integreret håndtag for nem transport.
- Pressure regulator for precise control of output pressure.
- Safety valve to prevent over-pressurization.
- Air filter for clean air intake.
- Oil level control for proper lubrication maintenance.
- Large wheels for convenient mobility.
- Drain cock for condensate removal from the tank.
- Quick coupling for easy attachment of air tools.
- Non-return valve.
- Oil-lubricated pump for enhanced durability.
- 10-year guarantee against tank rust.

Figur 1: Overview of the Einhell BT-AC 230/24 Compressor, showing its blue tank, black motor housing, and transport handle.

Figur 2: Nærbillede view of the compressor's pressure gauges and the adjustable pressure regulator, indicating variable pressure from 0-8 bar.
4. Opsætning
Before first use, some assembly and preparation are required:
- Fastgør hjul: Securely fasten the wheels to the compressor base using the provided hardware. This enhances mobility.
- Installer luftfilter: Screw the air filter into its designated port on the compressor pump. This protects the pump from dust and debris.
- Tjek oliestand: Verify the oil level using the oil level control (sight glass or dipstick). If necessary, add appropriate compressor oil to the recommended level. The pump is oil-lubricated.
- Placering: Place the compressor on a firm, level surface in a well-ventilated area. Ensure adequate space around the unit for air circulation.
- Elektrisk tilslutning: Connect the compressor to a grounded 230 V ~ 50 Hz power outlet. Ensure the power supply matches the compressor's requirements.
5. Betjeningsvejledning
Følg disse trin for sikker og effektiv drift:
- Indledende opstart:
- Ensure the drain cock is closed.
- Turn on the compressor. The motor will start, and the tank will begin to fill with air.
- Allow the compressor to reach its maximum operating pressure (max. 8 bar) and shut off automatically. This confirms proper function of the pressure switch.
- Justering af udgangstryk: Use the pressure regulator knob to set the desired working pressure for your air tool. Monitor the output pressure gauge.
- Tilslutning af luftværktøj: Attach your air tool to the quick coupling.
- Operation: Begynd at bruge dit luftværktøj. Kompressoren vil automatisk tænde og slukke for at opretholde tryk i tanken efter behov.
- Lukker ned:
- Sluk for kompressoren.
- Afbryd strømforsyningen.
- Slowly open the drain cock to release all air pressure from the tank. This is crucial for safety and to prevent tank rust.
6. Vedligeholdelse
Regular maintenance ensures the longevity and performance of your compressor:
- Daglig:
- Drain condensate from the tank using the drain cock. This prevents rust and maintains tank capacity.
- Weekly/After 10-20 Operating Hours:
- Check oil level and top up if necessary. Use only recommended compressor oil.
- Inspect the air filter. Clean or replace if it appears dirty or clogged.
- Monthly/After 50 Operating Hours:
- Check all bolts and fittings for tightness.
- Inspect hoses and connections for wear, cracks, or leaks.
- Årligt:
- Change the compressor oil.
- Have a qualified technician inspect the safety valve and pressure switch.
Warning: Always disconnect the power supply and release all pressure before performing any maintenance.
7. Fejlfinding
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Kompressoren starter ikke. | No power supply; Thermal overload activated; Faulty switch. | Check power connection and circuit breaker; Allow motor to cool down; Contact service. |
| Kompressoren kører kontinuerligt eller ofte. | Air leak in system; Drain cock open; Pressure switch malfunction. | Check all connections and hoses for leaks; Close drain cock; Contact service. |
| Lavt lufttryksudgang. | Pressure regulator set too low; Air filter clogged; Air leak. | Adjust pressure regulator; Clean/replace air filter; Check for leaks. |
| Overdreven støj eller vibrationer. | Loose components; Insufficient oil; Worn parts. | Tighten all bolts; Check/add oil; Contact service. |
8. Specifikationer
| Specifikation | Værdi |
|---|---|
| Fabrikant | Einhell |
| Varekode | BT-AC 230/24 |
| Modelnummer | 4010350 |
| Produktdimensioner | 27 x 59.5 x 60.5 cm |
| Tank kapacitet | 24 L |
| Varens vægt | 25 kg |
| Strømtype | Elektrisk med ledning |
| Voltage | 230 V |
| Wattage | 1500 W |
| Motorkraft | 1.5 kW (2 HP) S2 15 min |
| Luftstrømshastighed | 206 l/min |
| Hastighed | 2,850 rpm |
| Driftstryk | Maks. 8 bar |
| Antal cylindre | 1 |
| Type elektrisk stik | C - 2 pin Europlug |
| Inkluderede komponenter | Ingen yderligere komponenter |
9. Garanti og support
Einhell provides a 10-year guarantee against rust on the compressor tank. For warranty claims, technical support, or spare parts, please contact Einhell customer service or visit their official webwebstedet. Behold din købskvittering som købsbevis.
For further assistance, refer to the official Einhell webwebstedet eller kontakt deres autoriserede servicecentre.