AmScope MU1000-CK

AmScope MU1000-CK ​​10MP USB2.0 mikroskop digitalkamera brugsanvisning

Indledning

This manual provides detailed instructions for the installation, operation, and maintenance of your AmScope MU1000-CK 10MP USB2.0 Microscope Digital Camera. This camera is designed for capturing still images and streaming live video through a microscope, compatible with Windows and Mac operating systems.

Pakkens indhold

Bekræft, at alle nedenstående varer er til stede i din pakke:

  • AmScope MU1000-CK 10MP USB2.0 Digital Camera
  • USB 2.0-kabel
  • Software CD (for Windows and Mac)
  • 23 mm til 30 mm adapter
  • 23 mm til 30.5 mm adapter
  • Calibration Kit (calibration slide)
AmScope MU1000-CK 10MP USB2.0 Microscope Digital Camera and included accessories.

Image showing the AmScope MU1000-CK digital camera, USB cable, software CD, two microscope adapters (30mm and 30.5mm), and a calibration slide.

Opsætning

1. Software installation

Before connecting the camera, install the provided software from the CD or download the latest version from the AmScope webwebsted.

  • Windows-brugere: The software offers advanced features including stitching, Extended Depth of Focus (EDF), video recording, and measurement functions. It supports Windows XP/Vista/7/8/10.
  • Mac -brugere: The software allows still image capture, video recording, and control over color and exposure. Compatibility is for Mac OS X and Linux. Note that some advanced features available on Windows may not be present in the Mac version.

2. Camera Connection to Microscope

The camera is designed to fit various microscope eyepiece tubes or trinocular ports. Select the appropriate adapter for your microscope.

  1. Remove the eyepiece from your microscope's eyepiece tube or trinocular port.
  2. Insert the camera directly into a 23mm eyepiece tube. If your microscope has a 30mm or 30.5mm eyepiece tube, use the corresponding adapter.
  3. Ensure the camera is securely seated.

3. USB-forbindelse

Connect the camera to your computer using the provided USB 2.0 cable. The computer should recognize the device automatically after software installation.

AmScope MU1000-CK digital camera connected to a stereo microscope and laptop.

A stereo microscope with the AmScope MU1000-CK camera attached to its trinocular port, displaying a circuit board image on a connected laptop.

AmScope MU1000-CK digital camera connected to a compound microscope and laptop.

A compound microscope with the AmScope MU1000-CK camera attached to its trinocular port, displaying a biological sample image on a connected laptop.

Betjeningsvejledning

1. Launching the Software

Open the installed AmScope software application on your computer.

2. Lev View and Focus

Once the software is open, a live feed from the camera should appear. Adjust the microscope's focus knobs to achieve a clear image on your computer screen.

3. Billedoptagelse

Sådan optager du et stillbillede:

  1. Ensure the image is in focus.
  2. Click the 'Capture' or 'Snapshot' button within the software interface.
  3. Images can be saved in various formats (e.g., JPG, TIFF).

4. Videooptagelse

Sådan optager du video:

  1. Click the 'Record' button in the software.
  2. Click 'Stop' to end the recording.
  3. Recorded videos are typically saved in AVI or similar formats.

5. Calibration (Windows Only)

The included calibration kit allows for precise measurements within the Windows software. Refer to the software's help documentation for detailed calibration procedures.

  1. Place the calibration slide on your microscope stage.
  2. Focus on the scale on the calibration slide.
  3. Access the calibration function in the software and follow the on-screen prompts to define the scale.

6. Advanced Features (Windows Only)

The Windows software includes advanced features such as image stitching (combining multiple images into a larger one), Extended Depth of Focus (EDF) for creating images with greater depth of field, and comprehensive measurement tools. Consult the software manual for detailed usage.

Microscopic image of biological cells captured with the AmScope MU1000-CK camera.

En eksample of a microscopic image showing biological cells, demonstrating the camera's image capture capability.

Microscopic image of insect eggs captured with the AmScope MU1000-CK camera.

En eksample of a microscopic image showing insect eggs, illustrating the camera's detail capture.

Opretholdelse

  • Rengøring af kameralinsen: Use a soft, lint-free cloth or lens paper with a small amount of lens cleaning solution. Avoid touching the lens surface with bare fingers.
  • Rengøring af kamerahuset: Wipe the camera body with a dry, soft cloth. Do not use harsh chemicals or abrasive cleaners.
  • Opbevaring: Når kameraet ikke er i brug, skal det opbevares tørt og støvfrit, helst i originalemballagen eller et beskyttende etui.
  • Undgå ekstreme forhold: Do not expose the camera to extreme temperatures, high humidity, or direct sunlight for prolonged periods.

Fejlfinding

Almindelige problemer og løsninger:

  • No Live Image:

    Ensure the camera is securely connected to the USB port and the microscope. Verify that the software is correctly installed and running. Check if the camera is selected as the active device within the software.

  • Dårlig billedkvalitet:

    Adjust the microscope's focus. Ensure the lighting is adequate. Check software settings for exposure and white balance. Clean the camera lens and microscope optics if necessary.

  • Software genkender ikke kameraet:

    Reinstall the software and drivers. Try a different USB port or cable. Restart your computer. For Mac users, ensure you have the latest compatible software version, as some advanced features or full compatibility may vary.

  • Langsomt live View/Low Frame Rate:

    This can occur with high-resolution settings. Try reducing the preview resolution in the software settings. Ensure your computer meets the minimum system requirements.

Specifikationer

FeatureDetalje
ModelMU1000-CK
Sensoropløsning10 megapixel
InterfaceUSB 2.0
KompatibilitetWindows XP/Vista/7/8/10, Mac OS X, Linux
Mounting Sizes23mm, 30mm, 30.5mm (with included adapters)
Dimensioner6.69 x 5.91 x 2.36 tommer
Varens vægt1.17 pund
FabrikantUnited Scope LLC.
MaterialeMetal
FarveSort, klar

Garanti og support

For warranty information, please refer to the documentation included with your purchase or visit the official AmScope website. For technical support, software updates, or further assistance, please contact AmScope customer service directly.

Online ressourcer: www.amscope.com

Relaterede dokumenter - MU1000-CK

Preview AmScope DM150-W Full HD digitalt sammensat mikroskop brugermanual
Omfattende brugermanual til AmScope DM150-W Full HD digitalt sammensat mikroskop, der dækker opsætning, betjening, sikkerhed og vedligeholdelse for optimal brug.
Preview Brugermanual til AmScope M150-seriens mikroskop
Brugermanual til AmScope M150-serien af ​​mikroskoper, der dækker opsætning, betjening, vedligeholdelse, specifikationer og fejlfinding.
Preview Brugermanual til AmScope 120-seriens mikroskop
Omfattende brugermanual til AmScope 120-serien af ​​mikroskoper, der dækker opsætning, betjening, specifikationer og fejlfinding for modeller som B120 og T120.
Preview Brugermanual til AmScope SM-1-seriens stereomikroskop
Omfattende brugermanual til AmScope SM-1-serien af ​​stereomikroskoper, der dækker opsætning, betjening, specifikationer og fejlfinding for modeller som SM-1B/T, SM-1TS/BS og SM-1(B/T)-PL.
Preview AmScope 490-seriens sammensatte mikroskop brugermanual
Denne brugermanual indeholder omfattende instruktioner til AmScope 490-serien af ​​sammensatte mikroskoper, der dækker opsætning, betjening, vedligeholdelse og fejlfinding for optimal brug.
Preview Brugermanual til AmScope PM240-seriens stereomikroskop
Brugermanual til AmScope PM240-serien af ​​stereomikroskoper, der dækker opsætning, betjening, specifikationer og fejlfinding for binokulære og trinokulære modeller.