Amerec DKT60/K60-PB

Amerec KT60/K60 Digital Controls Brugermanual

Model: DKT60/K60-PB

Indledning

This manual provides essential information for the installation, operation, and maintenance of your Amerec KT60/K60 Digital Controls. These dual 3-button digital controls are designed to display temperature and time, offering precise management of your steam environment. The system includes both an internal control (KT60 with integral temperature sensor) and an external control (K60), along with necessary cables and a Comfort Flo steam head.

Opsætning og installation

The Amerec KT60/K60 Digital Control system is designed for integration with Amerec steam generators. Proper installation is crucial for optimal performance and safety. It is highly recommended that installation be performed by a qualified electrician or service technician.

Amerec KT60/K60 Digital Controls in Brass Finish

Image: The Amerec KT60/K60 Digital Controls, showing the polished brass finish and the digital display with "114" degrees, along with "TIME", "ON/OFF", and "TEMP" buttons. The image displays the front and side views of the control units.

Betjeningsvejledning

The KT60/K60 controls provide intuitive operation for your steam bath experience.

  1. Tænd/sluk: Tryk på ON/OFF button to activate or deactivate the steam generator. The digital display will illuminate when the unit is active.
  2. Justering af temperatur: Tryk på TEMP button. The display will show the current set temperature. Use the up/down arrows (if present, or repeated presses of TEMP/TIME buttons in some models) to adjust the temperature up to 125° F. The display will revert to showing the actual room temperature once set.
  3. Justeringstid: Tryk på TID button. The display will show the current set duration. Use the up/down arrows (or repeated presses) to adjust the steam session duration up to 60 minutes. The display will show the remaining time during operation.
  4. Vise: The digital display continuously shows the current temperature or remaining time, depending on the mode selected or during idle operation.

Opretholdelse

Regular maintenance ensures the longevity and optimal performance of your Amerec digital controls.

Fejlfinding

If you encounter issues with your Amerec KT60/K60 Digital Controls, consider the following basic troubleshooting steps:

Specifikationer

FeatureDetalje
FabrikantAmerec
VarenummerDKT60/K60-PB
Varens vægt3.75 pund
Pakkedimensioner11.8 x 9.1 x 3.2 tommer
VaremodelnummerDKT60/K60-PB
FarvePoleret messing
StilModerne
Vare Pakke Antal1
Adjustable Time DurationOp til 60 minutter
Justerbar temperaturUp to 125° F

Garantioplysninger

The Amerec KT60/K60 Digital Controls come with a limited warranty:

Please retain your proof of purchase for warranty claims. For full warranty terms and conditions, refer to the documentation included with your product or visit the official Amerec webwebsted.

Kundesupport

For technical assistance, service, or to order replacement parts, please contact Amerec customer support or an authorized service center. Contact information can typically be found on the manufacturer's webwebstedet eller i den originale produktemballage.

When contacting support, please have your product model number (DKT60/K60-PB) and serial number (if applicable) ready.

Relaterede dokumenter - DKT60/K60-PB

Preview Installations- og servicevejledning til Amerec AK dampgenerator
En omfattende vejledning til installation og service af Amerec AK-seriens dampgeneratorer (AK4.5, AK6, AK7.5, AK9, AK11, AK14). Dækker sikkerhedsforanstaltninger, montering, VVS, ledningsføring, styringsmuligheder og driftstest. Indeholder detaljer om systemer med én og flere generatorer.
Preview Specifikationsark for Amerec AK-serien af ​​dampgeneratorer
Detaljeret specifikationsark for Amerec AK-serien af ​​dampgeneratorer, der dækker ydeevnefunktioner, styringsmuligheder (K60, KT60), dimensionerings- og indbygningsvejledning, el- og VVS-krav samt installationsvejledning.
Preview Installations- og servicevejledning til Amerec AK dampgenerator
Omfattende vejledning til installation og service af Amerec AK-seriens dampgeneratorer, inklusive modellerne AK4.5, AK6, AK7.5, AK9, AK11 og AK14. Dækker sikkerhedsforanstaltninger, montering, vandkvalitet, VVS, ledningsføring og styringsmuligheder for forskellige Amerec-styringssystemer (K2, K3, KT3, K4, K5).
Preview Installations- og servicevejledning til Amerec AK dampgenerator
Omfattende installations- og servicemanual til Amerec AK dampgeneratorer, der dækker modellerne AK4.5, AK7.5, AK11 og AK14. Inkluderer ledningsføring, VVS, montering, styringsinstallation, sikkerhedsretningslinjer og driftsprocedurer.
Preview Amerec ADT automatisk afløbssæt: Installations- og servicevejledning
Omfattende installations- og servicevejledning til Amerec ADT automatisk afløbssæt til dampgeneratorer. Lær, hvordan du korrekt installerer, betjener og fejlfinder dette vigtige tilbehør.
Preview Amerec ADK automatisk afløbssæt: Installations- og servicevejledning
Detaljerede installations- og serviceinstruktioner til Amerec ADK automatisk afløbssæt. Denne vejledning dækker montering af sættet til Amerec AK/3K og AG/3G dampbadsgeneratorer, herunder VVS, ledningsføring, motormontering, driftstest og fejlfinding. Vigtige sikkerhedsadvarsler og professionelle installationskrav er fremhævet.