1. Introduktion
This manual provides detailed instructions for the proper installation, operation, and maintenance of the Geberit Flush Valve, Model 240.501.00.1. Please read this manual thoroughly before beginning any procedures to ensure safe and efficient use of the product. Retain this manual for future reference.
2. Produktet er slutview
The Geberit Flush Valve Model 240.501.00.1 is a critical component for toilet cisterns, designed for reliable flushing performance. Understanding its components is essential for installation and maintenance.

Figur 1: Geberit Flush Valve Model 240.501.00.1. This image shows the complete flush valve assembly, including the main body and the overflow pipe/mounting bracket.

Figur 2: eksploderede view of the Geberit Flush Valve components. This diagram illustrates the individual parts of the flush valve, including the main valve body, the overflow tube, the flush button rod, and the mounting bracket.
3. Opsætning og installation
Installation of the Geberit Flush Valve should ideally be performed by a qualified plumber or an individual with experience in plumbing systems. Incorrect installation can lead to leaks or improper function.
- Forberedelse: Turn off the water supply to the toilet and flush the toilet to empty the cistern. Remove the cistern lid.
- Fjern den gamle ventil: Disconnect the water supply line from the fill valve. Unscrew any retaining nuts or bolts holding the old flush valve in place. Carefully remove the old flush valve from the cistern.
- Clean Cistern: Clean the inside of the cistern, especially around the flush valve opening, to ensure a good seal for the new valve.
- Installer ny ventil: Place the new Geberit flush valve into the opening at the bottom of the cistern. Ensure the rubber seal is correctly seated. Secure the valve from underneath the cistern with the provided retaining nut, tightening it firmly but without over-tightening.
- Forbind komponenter: Attach the overflow pipe and any other necessary components as shown in the product diagram (Figure 2). Ensure all connections are secure.
- Vandforsyning: Tilslut vandforsyningsledningen til påfyldningsventilen igen.
- Prøve: Slowly turn on the water supply and check for leaks. Allow the cistern to fill and perform several test flushes to ensure proper operation and sealing.
Vigtig: Refer to the specific installation diagrams provided with your product packaging for precise component placement and torque specifications.
4. Betjeningsvejledning
The Geberit Flush Valve is designed for efficient water usage. Operation typically involves a standard flush mechanism.
- Standard Flush: Press the flush button or lever completely to initiate a full flush. This will empty the cistern, providing a complete rinse of the toilet bowl.
- Adjusting Flush Volume (if applicable): Some Geberit flush valves allow for adjustment of the flush volume. Consult the specific instructions that came with your product for details on how to adjust the water level or flush duration, if this feature is present on your model.
5. Vedligeholdelse
Regular maintenance ensures the longevity and optimal performance of your Geberit Flush Valve.
- Rensning: Periodically clean the flush valve components, especially the rubber seals, to prevent mineral buildup and ensure a proper seal. Use a soft brush and mild cleaning solution. Avoid harsh chemicals that can damage rubber or plastic parts.
- Inspektion: Inspect the valve for any signs of wear, cracks, or damage to the seals. Worn seals are a common cause of leaks.
- Udskiftningsdele: If any part of the flush valve is damaged or worn beyond repair, replace it with genuine Geberit spare parts to maintain compatibility and performance.
6. Fejlfinding
Below are common issues and their potential solutions for the Geberit Flush Valve.
| Problem | Mulig årsag | Løsning |
|---|---|---|
| Toilet runs continuously (leaks) | Worn or dirty flush valve seal; improper seating of the valve. | Clean or replace the flush valve seal. Ensure the valve is correctly seated and secured. |
| Incomplete flush | Low water level in cistern; obstruction in the flush mechanism. | Check and adjust the water level. Inspect the flush valve for any obstructions and clear them. |
| Flush button/lever sticks | Mechanism binding; debris. | Inspect the flush button/lever mechanism for obstructions or misalignment. Clean as necessary. |
If these solutions do not resolve the issue, it is recommended to contact a qualified plumber or Geberit customer support.
7. Specifikationer
Key technical specifications for the Geberit Flush Valve Model 240.501.00.1:
- Modelnummer: 240.501.00.1
- Materiale: Rustfrit stål
- Dimensioner (L x B x H): 11.89 x 4.09 x 4.09 tommer
- Varens vægt: 10.6 ounce
- Indløbsforbindelsestype: Sved
- Udgangstilslutningstype: BSPT
- Størrelse på stikkontakttilslutning: 32 millimeter
- Fabrikant: Geberit
8. Garanti og support
For warranty information, please refer to the documentation provided at the time of purchase or visit the official Geberit webGarantibetingelserne kan variere afhængigt af region og forhandler.